Flow Rate Range |
0.01 to 150 ml/min (up to 300 ml/min during column packing) |
|
Flow Rate Accuracy |
± 1.5% |
|
Flow Rate Precision |
RSD <0.5% |
|
Pressure Range |
0 to 5 MPa (725 psi) |
|
Pressure Limits |
Programmable upper and lower |
|
Viscosity Range |
0.35 to 5 cP |
|
|
|
|
Wavelength Range |
280 nm (Fixed) |
|
Absorbance Range |
-6 to 6 AU |
|
Resolution |
0.001 mAU |
|
Wavelength Reproducibility |
± 0.01 nm |
|
Linearity |
Within ± 5% at 0 to 2 AU |
|
Drift |
≤ | 0.2 mAU | AU/h (2 mm cell at 280 nm) |
|
Noise |
< 0.1 mAU |
|
Operating Pressure |
0 to 2 MPa |
|
Lamp Operating Time |
> 10,000 hours |
|
Flow Cell |
Optical path length: 2 mm Cell volume: 2 ul Total volume: 30 ul |
|
|
|
|
Conductivity Range |
0.01 to 999.9 mS/cm |
|
Accuracy |
± 0.01 mS/cm or ± 2%, whichever is greater (within 0.3 to 300 mS/cm) |
|
Operating Pressure |
0 to 5 MPa |
|
Flow Cell Volume |
22 ul |
|
Temperature Monitor Range |
0°C to 99°C |
|
Temperature Monitor Accuracy |
± 1.5°C within 4°C to 45°C |
|
|
|
|
pH Reading Range |
0 to 14 |
|
Accuracy |
± 0.1 pH unit within pH 2 to 12, temperature within ± 3°C from calibration temperature |
|
Operating Pressure |
0 to 0.5 MPa |
|
Flow Cell Volume |
76 ul |
|
|
|
|
Number of Fractions |
Up to 576 |
|
Vessel Types |
Deep well plates, 96, 48, or 24 wells |
|
Fraction Volumes |
0.1 to 250 ml
|
|
Spillage-Free Mode |
Automatic, Drop Sync, or Accumulator |
|
Flammable Liquids |
No |
|
Delay Volume (UV-Dispenser Head) |
205 ul, 86 ul with optional tubing kit (i.d. 0.25 mm) |
|
Dimensions (W x D x H) |
15.4 x 23 x 12.6 (39 x 58.5 x 32 cm) |
|
Weight |
46.3 lb. (21 kg) |

|
|
|
|
Flow Rate Range |
0.01 to 150 ml/min (up to 300 ml/min during column packing) |
|
Flow Rate Accuracy |
± 1.5% |
|
Flow Rate Precision |
RSD <0.5% |
|
Pressure Range |
0 to 5 MPa (725 psi) |
|
Pressure Limits |
Programmable upper and lower |
|
Viscosity Range |
0.35 to 5 cP |
|
|
|
|
Wavelength Range |
190 to 700 nm in steps of 1 nm, up to 3 wavelengths |
|
Absorbance Range |
-6 to 6 AU |
|
Resolution |
0.001 mAU |
|
Wavelength Reproducibility |
± 0.01 nm |
|
Linearity |
Within ± 2% at 0 to 2 AU |
|
Drift |
≤ | 0.2 mAU | AU/h (2 mm cell at 280 nm) |
|
Noise |
< 0.08 mAU |
|
Operating Pressure |
0 to 2 MPa |
|
Lamp Operating Time |
> 5000 hours |
|
Flow Cell |
Optical path length: 2 mm Cell volume: 2 ul Total volume: 11 ul |
|
|
|
|
Conductivity Range |
0.01 to 999.9 mS/cm |
|
Accuracy |
± 0.01 mS/cm or ± 2%, whichever is greater (within 0.3 to 300 mS/cm) |
|
Operating Pressure |
0 to 5 MPa |
|
Flow Cell Volume |
22 ul |
|
Temperature Monitor Range |
0°C to 99°C |
|
Temperature Monitor Accuracy |
± 1.5°C within 4°C to 45°C |
|
|
|
|
pH Reading Range |
0 to 14 |
|
Accuracy |
± 0.1 pH unit within pH 2 to 12, temperature within ± 3°C from calibration temperature |
|
Operating Pressure |
0 to 0.5 MPa |
|
Flow Cell Volume |
76 ul |
|
|
|
|
Number of Fractions |
Up to 576 |
|
Vessel Types |
Deep well plates, 96, 48, or 24 wells |
|
Fraction Volumes |
0.1 to 250 ml
|
|
Spillage-Free Mode |
Automatic, Drop Sync, or Accumulator |
|
Flammable Liquids |
No |
|
Delay Volume (UV-Dispenser Head) |
205 ul, 86 ul with optional tubing kit (i.d. 0.25 mm) |
|
Dimensions (W x D x H) |
15.4 x 23 x 12.6 (39 x 58.5 x 32 cm) |
|
Weight |
46.3 lb. (21 kg) |