{"title":"Mass Spectrometry","description":"\u003cdiv class=\"category-description\"\u003e\n\tNeed help selecting a product? Use our new filter tool to help you find the right product.\n\u003c\/div\u003e\n\u003clink href=\"https:\/\/www.marshallscientific.com\/v\/vspfiles\/marshall-select.css\" rel=\"stylesheet\" type=\"text\/css\"\u003e","products":[{"product_id":"agilent-6120b-single-quadrupole-mass-spectrometer","title":"Agilent 6120B Single Quadrupole Mass Spectrometer","description":"\u003cdiv class=\"productdescriptiontables\"\u003e\n\t\u003ch1\u003eAgilent 6120B Single Quadrupole Mass Spectrometer\u003c\/h1\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-section\"\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eMass Range\u003c\/b\u003e\u003cbr\u003e2 to 2,000 m\/z\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eMass Accuracy\u003c\/b\u003e\u003cbr\u003e± 0.13 Da\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eScan Speed\u003c\/b\u003e\u003cbr\u003e10,400 Da\/sec\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"features-section\"\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cspan class=\"features-header\"\u003eFeatures\u003c\/span\u003e\n\t\t\t\u003cul\u003e\n\t\t\t\t\u003cli\u003eFeatures 300 msec ion polarity switching for maximum data collection\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eSupports multiple ionization sources including ESI, APCI, APPI, and multimode options\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eProvides dynamic range exceeding 6 × 10⁶ for reliable quantitation\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eEnsures long-term stability with \u0026lt; 0.1 amu mass drift over 12 hours\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eHigh-performance detector with high gain electron multiplier horn\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eFully controlled via Agilent ChemStation Workstation Software for streamlined operation\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eSIM sensitivity with signal-to-noise ratio \u0026gt; 75:1 for ESI positive mode\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eMaximum SIM dwell time of 5 msec for fast, accurate quantitation\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eEquipped with a reliable vacuum system featuring a turbo-molecular and mechanical pump\u003c\/li\u003e\n\t\t\t\u003c\/ul\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-6120BMS1200_11103bc0-860a-4e09-a691-54450b3f0999.jpg?v=1779985706\"\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\n\tThe Agilent 6120B Single Quadrupole Mass Spectrometer delivers unmatched analytical performance and proven day-after-day reliability from routine QC to research applications. This 6120B model is specifically a flexible, high performance solution ideal for any quantitation application with a 2 to 2,000 m\/z mass range and 1 pg sensitivity. This system allows users to rapidly screen compounds and confirm molecular weights, purify target compounds in complex mixtures, quantitate target compounds, positively identify impurities and more. The Agilent 6120B Single Quadrupole Mass Spectrometer provides unmatched sensitivity, simplifying sample preparation. An ultrafast scan speed allows users to take full advantage of LC separations when paired with an Agilent LC System, as well as featuring ultrafast ion polarity switching to return maximum information from a single injection, even with narrow LC peaks. The Agilent 6120B Single Quadrupole Mass Spectrometer can be fully controlled from the included Agilent ChemStation Workstation Software, which allows for user-friendly operation in data acquisition, analysis, instrument control, automation, and more.\n\t\u003cbr\u003e\u003cbr\u003e\u003cb\u003eThis Agilent MS system was recertified and calibrated by a factory trained engineer and is ready to ship on demand. This system comes with everything needed for easy installation and setup. All of our equipment is fully tested to perform at factory specifications before being shipped.\u003c\/b\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"included-box\"\u003e\n\t\t\u003cspan class=\"included-header\"\u003eINCLUDED:\u003c\/span\u003e\u003cbr\u003eThe Agilent 6120B Single Quadrupole Mass Spectrometer includes:\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eAgilent 6120B Single Quadrupole Mass Spectrometer\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eAgilent MS40+ Rotary Vane Vacuum Pump\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eG1948B ESI Ionization Source\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eWindows 11 Professional 64-Bit Data Station with Flatscreen Monitor\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eChemStation Version 4.3 Software Installed\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eAll Power Cords\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eCan\/Crossover Cables\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eLab Advisor Diagnostics Report \u0026amp; Mass Spec Tuning Report\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eFull 180 Day Parts and Labor Warranty\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003ch2\u003eAgilent 6120B Single Quadrupole Mass Spectrometer Specifications\u003c\/h2\u003e\n\t\u003ctable\u003e\n\t\u003ctbody\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tMaximum Scan Speed\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t10,400 Da\/sec\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tSIM Sensitivity, ESI Positive\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tSignal-to-noise ratio \u0026gt; 75:1 (1 pg of reserpine injected on column,\n\t\t\t\u003cbr\u003equantifying the m\/z 609 ion)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tSIM Sensitivity, APCI Positive\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tSignal-to-noise ratio \u0026gt; 10:1 (1 pg of reserpine injected on column,\n\t\t\t\u003cbr\u003equantifying the m\/z 609 ion)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tPolarity Switching\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t300 msec (switching time from positive to negative polarity)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tMass Resolution (Autotune)\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tUnit resolution (full width at half maximum)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tMass Stability\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u0026lt; 0.1 amu or 100 ppm, whichever is larger (over 12 hours)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tMass Accuracy\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t± 0.13 Da\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tMaximum SIM Dwell Time\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t5 msec\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tMaximum SIM Transitions\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t100 (one time segment)\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDynamic Range\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u0026gt; 6 × 10 \n\t\t\t\u003csup\u003e6\u003c\/sup\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tMass Range\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t2 to 2,000 m\/z\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tSingle Point of Control\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tSingle-point data system method capability with full control of Agilent 1200 Series LC Systems and 6100 Series Single Quadrupole LC\/MS Systems\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tTime Programming\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tSIM ion selections, Scan functions, Fragmentor voltage, External CAN valves\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tIonization Sources\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tElectrospray (ESI), Multimode source (simultaneous ESI and APCI), Atmospheric pressure chemical ionization (APCI), ChipCube for intergrated nanoLC, Atmospheric pressure photoionization (APPI)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDetector\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tHigh energy conversion dynode and high gain electron multiplier horn\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tVacuum System\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tOne turbo-molecular pump with one mechanical pump\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDimensions (W x H x D)\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t14 x 18 x 25 in. (35 x 45 x 63.5 cm)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tWeight\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t137.6 lb. (63.4 kg.)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tElectrical Requirements\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t200-230VAC, 60Hz or 200-240VAC, 50Hz\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\t\u003c\/table\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003ctable\u003e\n\t\u003ctbody\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd colspan=\"2\"\u003e\n\t\t\t\u003ccenter\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t\tComputer Specifications\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003c\/center\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\tProcessor\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\tIntel Core I5-8500 CPU\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\tRAM\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\t32.0 GB\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\tHard Drive\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\t500GB Internal SSD\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\tOperating System\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\tWindows 11 Professional, 64-bit\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\t\u003c\/table\u003e\n\t\u003cspan class=\"downloads-header\"\u003eDownloads\u003c\/span\u003e\n\t\u003cdiv class=\"downloads-section\"\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_6120B_Single_Quadrupole_Mass_Spectrometer_-_Marshall_Scientific.pdf?v=1779985710\" target=\"blank\"\u003e\n\t\t\tTechnical Specification Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_6100_Series_Single_Quadrupole_Mass_Spectrometers_Manual_-_Marshall_Scientific.pdf?v=1779985716\" target=\"blank\"\u003e\n\t\t\tOperator's Manual Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_6100_Series_Single_Quadrupole_Mass_Spectrometers_Site_Preparation_Guide_-_Marshall_Scientific.pdf?v=1779985720\" target=\"blank\"\u003e\n\t\t\tSite Prep Guide Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"formalquote2\"\u003e\n\t\t\u003ca class=\"formalquote2link\" href=\"\/formal_quote_a\/2932.htm\" target=\"blank\"\u003eRequest a Formal Quote\u003c\/a\u003e\n\t\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cspan class=\"windows11\"\u003e\u003c\/span\u003e","brand":"My Store","offers":[{"title":"Default Title","offer_id":42474490003546,"sku":"AG-6120BMS","price":49995.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-6120BMS-2.jpg?v=1761206201"},{"product_id":"agilent-6120b-single-quadrupole-mass-spectrometer-w-1200-lc-system","title":"Agilent 6120B Single Quadrupole Mass Spectrometer w\/ 1200 LC System","description":"\u003cdiv class=\"productdescriptiontables\"\u003e\n\t\u003ch1\u003eAgilent 6120B Single Quadrupole Mass Spectrometer w\/ 1200 LC System\u003c\/h1\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-section\"\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eMass Range\u003c\/b\u003e\u003cbr\u003e2 to 2,000 m\/z\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eMass Accuracy\u003c\/b\u003e\u003cbr\u003e± 0.13 Da\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eScan Speed\u003c\/b\u003e\u003cbr\u003e10,400 Da\/sec\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"features-section\"\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cspan class=\"features-header\"\u003eFeatures\u003c\/span\u003e\n\t\t\t\u003cul\u003e\n\t\t\t\t\u003cli\u003eFeatures 300 msec ion polarity switching for maximum data collection\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eSupports multiple ionization sources including ESI, APCI, APPI, and multimode options\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eProvides dynamic range exceeding 6 × 10⁶ for reliable quantitation\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eEnsures long-term stability with \u0026lt; 0.1 amu mass drift over 12 hours\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eHigh-performance detector with high gain electron multiplier horn\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eFully controlled via Agilent ChemStation Workstation Software for streamlined operation\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eSIM sensitivity with signal-to-noise ratio \u0026gt; 75:1 for ESI positive mode\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eMaximum SIM dwell time of 5 msec for fast, accurate quantitation\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eEquipped with a reliable vacuum system featuring a turbo-molecular and mechanical pump\u003c\/li\u003e\n\t\t\t\u003c\/ul\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-6120BMS1200_11103bc0-860a-4e09-a691-54450b3f0999.jpg?v=1779985706\"\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\n\tThe Agilent 6120B Single Quadrupole Mass Spectrometer w\/ 1200 LC System delivers unmatched analytical performance and proven day-after-day reliability from routine QC to research applications. This 6120B model is specifically a flexible, high performance solution ideal for any quantitation application with a 2 to 2,000 m\/z mass range and 1 pg sensitivity. This system allows users to rapidly screen compounds and confirm molecular weights, purify target compounds in complex mixtures, quantitate target compounds, positively identify impurities and more. The Agilent 6120B Single Quadrupole Mass Spectrometer w\/ 1200 LC System provides unmatched sensitivity, simplifying sample preparation. An ultrafast scan speed allows users to take full advantage of LC separations when paired with an Agilent LC System, as well as featuring ultrafast ion polarity switching to return maximum information from a single injection, even with narrow LC peaks. The Agilent 6120B Single Quadrupole Mass Spectrometer w\/ 1200 LC System can be fully controlled from the included Agilent ChemStation Workstation Software, which allows for user-friendly operation in data acquisition, analysis, instrument control, automation, and more.\n\t\u003cbr\u003e\u003cbr\u003e\u003cb\u003eThis Agilent LC\/MS system was recertified and calibrated by a factory trained engineer and is ready to ship on demand. This system comes with everything needed for easy installation and setup. All of our equipment is fully tested to perform at factory specifications before being shipped.\u003c\/b\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"included-box\"\u003e\n\t\t\u003cspan class=\"included-header\"\u003eINCLUDED:\u003c\/span\u003e\u003cbr\u003eThe Agilent 6120B Single Quadrupole Mass Spectrometer w\/ 1200 LC System includes:\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eAgilent 6120B Single Quadrupole Mass Spectrometer\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eAgilent MS40+ Rotary Vane Vacuum Pump\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eG1948B ESI Ionization Source\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eG1312B Binary Pump (G1311A Quaternary Pump available, please inquire)\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eG1329A Autosampler\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eG1330B ALS Thermostat\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eG1316A TCC \u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eG1379B Degasser\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eG1315C DAD Detector\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eWindows 11 Professional 64-Bit Data Station with Flatscreen Monitor\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eChemStation Version 4.3 Software Installed\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eAll Power Cords\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eCan\/Crossover Cables\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eAgilent Lan Interface Card Built-In\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eSolvent Tubing\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eCapillaries\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eAgilent 4 Peak Test w\/ Lab Advisor Diagnostics Report \u0026amp; Mass Spec Tuning Report\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eFull 180 Day Parts and Labor Warranty\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"agilent-tests\"\u003e\n\t\t\u003cspan class=\"agilent-tests-title\"\u003eBelow is a List of Diagnostic Tests Performed On This LC System\u003c\/span\u003e\u003cbr\u003e\n\t\t\u003cspan class=\"agilent-tests-header\"\u003eG1315C Diode Array Detector Diagnostic Tests:\u003c\/span\u003e\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003eFilter Test: The test moves the filter into the light path and measures the relative absorbance in the filter position.\u003c\/li\u003e\n\t\t\t\u003cli\u003eDark Current Test: The test measures the dark current from the detector optic.\u003c\/li\u003e\n\t\t\t\u003cli\u003eHolmium Oxide Test: The test measures the Holmium spectrum from the built-in Holmium filter. The spectrum is evaluated for peaks at different wavelengths.\u003c\/li\u003e\n\t\t\t\u003cli\u003eLamp Intensity Test: The test verifies functionality of the UV lamp at various wavelengths.\u003c\/li\u003e\n\t\t\t\u003cli\u003eWavelength Intensity Test: The test confirms the accuracy of wavelengths measured.\u003c\/li\u003e\n\t\t\t\u003cli\u003e Baseline Noise Test: The test measures the amount of baseline noise drift identified by the detector.\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\t\u003cspan class=\"agilent-tests-header\"\u003eG1312B Binary Pump Diagnostic Tests:\u003c\/span\u003e\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003ePressure Test: The pressure test is a quick, built-in test designed to demonstrate the pressure tightness (up to 400 bar) of the system.\u003c\/li\u003e\n\t\t\t\u003cli\u003eLeak Test: The leak test is a built-in troubleshooting designed to demonstrate the leak-tightness of the pump.\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\t\u003cspan class=\"agilent-tests-header\"\u003eG1316A Column Compartment Diagnostic Tests:\u003c\/span\u003e\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003eThermostat Test: Evaluates the cooling and heating performance of the two Peltier elements.\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\t\u003cspan class=\"agilent-tests-header\"\u003eG1329A Autosampler Diagnostic Tests:\u003c\/span\u003e\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e Injector Steps: Performs each movement of the sampling sequence under manual control. This is useful for confirming autosampler functionality.\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\t\u003cspan class=\"agilent-tests-header\"\u003eSystem Tests:\u003c\/span\u003e\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e4 Peak Test (Isocratic Standard): Standard test published by Agilent to confirm complete functionality of the 1200 LC System.\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003ch2\u003eAgilent 6120B Single Quadrupole Mass Spectrometer w\/ 1200 LC System Specifications\u003c\/h2\u003e\n\t\u003ctable\u003e\n\t\u003ctbody\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tMaximum Scan Speed\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t10,400 Da\/sec\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tSIM Sensitivity, ESI Positive\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tSignal-to-noise ratio \u0026gt; 75:1 (1 pg of reserpine injected on column,\n\t\t\t\u003cbr\u003equantifying the m\/z 609 ion)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tSIM Sensitivity, APCI Positive\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tSignal-to-noise ratio \u0026gt; 10:1 (1 pg of reserpine injected on column,\n\t\t\t\u003cbr\u003equantifying the m\/z 609 ion)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tPolarity Switching\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t300 msec (switching time from positive to negative polarity)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tMass Resolution (Autotune)\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tUnit resolution (full width at half maximum)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tMass Stability\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u0026lt; 0.1 amu or 100 ppm, whichever is larger (over 12 hours)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tMass Accuracy\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t± 0.13 Da\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tMaximum SIM Dwell Time\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t5 msec\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tMaximum SIM Transitions\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t100 (one time segment)\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDynamic Range\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u0026gt; 6 × 10 \n\t\t\t\u003csup\u003e6\u003c\/sup\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tMass Range\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t2 to 2,000 m\/z\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tSingle Point of Control\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tSingle-point data system method capability with full control of Agilent 1200 Series LC Systems and 6100 Series Single Quadrupole LC\/MS Systems\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tTime Programming\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tSIM ion selections, Scan functions, Fragmentor voltage, External CAN valves\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tIonization Sources\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tElectrospray (ESI), Multimode source (simultaneous ESI and APCI), Atmospheric pressure chemical ionization (APCI), ChipCube for intergrated nanoLC, Atmospheric pressure photoionization (APPI)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDetector\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tHigh energy conversion dynode and high gain electron multiplier horn\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tVacuum System\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tOne turbo-molecular pump with one mechanical pump\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDimensions (W x H x D)\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t14 x 18 x 25 in. (35 x 45 x 63.5 cm)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tWeight\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t137.6 lb. (63.4 kg.)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tElectrical Requirements\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t200-230VAC, 60Hz or 200-240VAC, 50Hz\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\t\u003c\/table\u003e\n\t\u003cbr\u003e\n\t\u003cdiv class=\"show-hidden-table\"\u003e\nClick Here to View Specifications for the Agilent 1200 LC System\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\n\t\u003cdiv class=\"hidden-table\"\u003e\n\t\t\u003ctable\u003e\n\t\t\u003ctbody\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cstrong\u003eDAD Detector\u003c\/strong\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cstrong\u003eSpecification\u003c\/strong\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tDetection Type\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t1024-element photodiode array\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tLight Source\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tDeuterium and tungsten lamps\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tWavelength Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t190 - 950 nm\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tShort Term Noise (ASTM) Single and Multi-Wavelength\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t± 0.8 × 10\n\t\t\t\t\u003csup\u003e-5\u003c\/sup\u003e AU at 254 and 750 nm\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tDrift\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t0.9 × 10\n\t\t\t\t\u003csup\u003e-3\u003c\/sup\u003e AU\/hr at 254 nm\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tLinear Absorbance Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u0026gt; 2.0 AU (upper limit)\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tWavelength Accuracy\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t± 1 nm\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tWavelength Bunching\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t1 - 400 nm\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tSlit Width\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t1, 2, 4, 8, 16 nm\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tDiode Width\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u0026lt; 1 nm\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tFlow Cells\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cp\u003e\n\t\t\t\t\tStandard: 13 µL volume, 10 mm cell path length and 120 bar (1740 psi) pressure maximum\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cstrong\u003eBinary Pump\u003c\/strong\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cstrong\u003eSpecification\u003c\/strong\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tHydraulic System\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tTwo dual piston in series pumps with proprietary servo-controlled variable stroke drive, floating piston design and active inlet valve\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tSetable Flow Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t0.001 – 5 ml\/min, in 0.001 ml\/min increments\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tFlow Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cp\u003e\n\t\t\t\t\t0.1 - 5.0 mL\/min\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tFlow Precision\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t≤ 0.07% RSD or ≤ 0.02 min SD, whatever is greater\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tFlow Accuracy\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t± 1% or 10 µl\/min, what ever is greater\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tPressure Operating Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tOperating range 0 to 600 bar (0 – 7800 psi) up to 5 ml\/min\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tPressure Pulsation\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u0026lt; 2 % amplitude (typically \u0026lt; 1 %), at 1 ml\/min isopropanol, at all pressures \u0026gt; 1 MPa\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tCompressibility Compensation\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tUser-selectable, based on mobile phase compressibility\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tRecommended pH Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t1.0 - 12.5\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tGradient Formation\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tHigh-pressure binary mixing\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tDelay Volume\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t600 to 800 µl, dependent on back pressure\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tComposition Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t0 to 100% (1 to 99% or 5 µl\/min per channel, whatever is greater is recommended)\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tComposition Precision\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u0026lt; 0.15% RSD\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tComposition Accuracy\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t± 0.35% absolute\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cstrong\u003eAutosampler\u003c\/strong\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cstrong\u003eSpecification\u003c\/strong\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tInjection Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t0.1 - 100 µl in 0.1 µl increments\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tPrecision\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cp\u003e\n\t\t\t\t\t\u0026lt; 0.25 % RSD of peak areas from 5 to 100 µl\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\t\u003cp\u003e\n\t\t\t\t\t\u0026lt; 1 % RSD of peak areas from 1 to 5 µl\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tPressure Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tOperating range 0 - 60 MPa (0 - 600 bar, 0 - 8850 psi)\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tSample Viscosity Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t0.2 to 50 cp\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tSample Capacity\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t100 × 2 mL vials in 1 tray\n\t\t\t\t\u003cbr\u003e40 × 2 mL vials in ½ tray\u003cbr\u003e15 × 6 mL vials in ½ tray (Agilent vials only)\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tInjection Cycle Time\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t50 s for draw speed 200 µL\/min, ejection speed 200 µL\/min, injection volume 5 µL\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tCarryover\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tTypically \u0026lt; 0.1 %, \u0026lt; 0.05 % with external needle cleaning\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cstrong\u003eALS Thermostat\u003c\/strong\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cstrong\u003eSpecification\u003c\/strong\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tTemperature Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t4°C to 40°C in 1°C increments\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tTemperature Accuracy at Ambient Temperatures \u0026lt; 25°C and Humidity \u0026lt; 50%\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t-1°C to +4°C at a setpoint of 4°C\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tTemperature Accuracy at Ambient Temperatures \u0026gt; 25°C and Humidity \u0026gt; 50%\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t-1°C to +5°C at a setpoint of 4°C\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cstrong\u003eColumn Compartment\u003c\/strong\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cstrong\u003eSpecification\u003c\/strong\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tTemperature Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tAmbient -10°C to 80°C at flow rates up to 5 mL\/min\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tTemperature Stability\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t± 0.15 °C\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tTemperature Accuracy\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t± 0.8°C (± 0.5°C with calibration)\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tColumn Capacity\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tThree 30 cm\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tWarm-Up\/Cool-Down Time\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t5 minutes from ambient to 40°C\n\t\t\t\t\u003cbr\u003e10 minutes from 40°C to 20°C\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tDead Volume\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cp\u003e\n\t\t\t\t\t3 µl left heat exchanger\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\t\u003cp\u003e\n\t\t\t\t\t6 µl right heat exchanger\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cstrong\u003eDegasser\u003c\/strong\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cstrong\u003eSpecification\u003c\/strong\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tNumber of Solvent Channels\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t4\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tMaximum Flow Rate\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t0 - 10 mL\/min per channel\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tInternal Volume Per Channel\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tTypically 12 ml per channel\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tMaterials in Contact with Solvent\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tPTFE, PEEK\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tpH Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t1 - 14\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003c\/tbody\u003e\n\t\t\u003c\/table\u003e\n\t\t\u003cbr\u003e\u003cbr\u003e\n\t\t\u003ctable\u003e\n\t\t\u003ctbody\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd colspan=\"2\"\u003e\n\t\t\t\t\u003ccenter\u003e\n\t\t\t\t\u003cp\u003e\n\t\t\t\t\tComputer Specifications\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\t\u003c\/center\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tProcessor\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tIntel Core I5-8500 CPU\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tRAM\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t32.0 GB\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tHard Drive\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t500GB Internal SSD\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tOperating System\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tWindows 11 Professional, 64-bit\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003c\/tbody\u003e\n\t\t\u003c\/table\u003e\n\t\u003c\/div\u003e\n\t\u003cspan class=\"downloads-header\"\u003eDownloads\u003c\/span\u003e\n\t\u003cdiv class=\"downloads-section\"\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_6120B_Single_Quadrupole_Mass_Spectrometer_-_Marshall_Scientific.pdf?v=1779985710\" target=\"blank\"\u003e\n\t\t\tTechnical Specification Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_6100_Series_Single_Quadrupole_Mass_Spectrometers_Manual_-_Marshall_Scientific.pdf?v=1779985716\" target=\"blank\"\u003e\n\t\t\tOperator's Manual Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_6100_Series_Single_Quadrupole_Mass_Spectrometers_Site_Preparation_Guide_-_Marshall_Scientific.pdf?v=1779985720\" target=\"blank\"\u003e\n\t\t\tSite Prep Guide Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"formalquote2\"\u003e\n\t\t\u003ca class=\"formalquote2link\" href=\"\/formal_quote_a\/2940.htm\" target=\"blank\"\u003eRequest a Formal Quote\u003c\/a\u003e\n\t\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cspan class=\"windows11\"\u003e\u003c\/span\u003e","brand":"My Store","offers":[{"title":"Default Title","offer_id":42474490200154,"sku":"AG-6120BMS1200","price":70995.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-6120BMS1200-2.jpg?v=1761206235"},{"product_id":"agilent-6130b-single-quadrupole-mass-spec-w-agilent-1200-ms-lc-system","title":"Agilent 6130B Single Quadrupole Mass Spec w\/ Agilent 1200 MS\/LC System","description":"\u003cdiv class=\"productdescriptiontables\"\u003e\n\t\u003ch1\u003eAgilent 6130B Single Quadrupole Mass Spec w\/ Agilent 1200 MS\/LC System\u003c\/h1\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-section\"\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eMass Range\u003c\/b\u003e\u003cbr\u003e10 to 3,000 m\/z\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eMass Accuracy\u003c\/b\u003e\u003cbr\u003e± 0.13 Da\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eScan Speed\u003c\/b\u003e\u003cbr\u003e10,400 Da\/sec\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"features-section\"\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cspan class=\"features-header\"\u003eFeatures\u003c\/span\u003e\n\t\t\t\u003cul\u003e\n\t\t\t\t\u003cli\u003eFeatures 30 msec ultrafast ion polarity switching for maximum data collection\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eSupports multiple ionization sources including ESI, APCI, APPI, and multimode options\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eProvides dynamic range exceeding 6 × 10⁶ for reliable quantitation\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eEnsures long-term stability with \u0026lt; 0.1 amu mass drift over 12 hours\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eHigh-performance detector with high gain electron multiplier horn\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eFully controlled via Agilent ChemStation Workstation Software for streamlined operation\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eSIM sensitivity with signal-to-noise ratio \u0026gt; 250:1 for ESI positive mode\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eMaximum SIM dwell time of 5 msec for fast, accurate quantitation\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eEquipped with a reliable vacuum system featuring a turbo-molecular and mechanical pump\u003c\/li\u003e\n\t\t\t\u003c\/ul\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/6140B_fb5929fe-7753-4dc4-a323-785ee1314662.jpg?v=1779985726\"\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\n\tThe Agilent 6130B Single Quadrupole Mass Spec w\/ Agilent 1200 MS\/LC System delivers unmatched analytical performance and proven day-after-day reliability from routine QC to research applications. This 6130B model is specifically a flexible, high performance solution ideal for any quantitation application with 3000 Da mass range and 1 pg sensitivity. This system allows users to rapidly screen compounds and confirm molecular weights, purify target compounds in complex mixtures, quantitate target compounds, positively identify impurities and more. The Agilent 6130B Single Quadrupole Mass Spec provides unmatched sensitivity, simplifying sample preparation and LC method development. An ultrafast scan speed allows users to take full advantage of UHPLC separations, as well as featuring ultrafast ion polarity switching to return maximum information from a single injection, even with narrow LC peaks. The Agilent 6130B Single Quadrupole Mass Spec w\/ Agilent 1200 MS\/LC System can be fully controlled from the included Agilent ChemStation Workstation Software, which allows for user-friendly operation in data acquisition, analysis, instrument control, automation, and more.\n\t\u003cbr\u003e\u003cbr\u003e\u003cb\u003eThis turnkey Agilent LC\/MS system was recertified and calibrated by a factory trained engineer and is ready to ship on demand. This system comes with everything needed for easy installation and setup. All of our equipment is fully tested to perform at factory specifications before being shipped.\u003c\/b\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"included-box\"\u003e\n\t\t\u003cspan class=\"included-header\"\u003eINCLUDED:\u003c\/span\u003e\u003cbr\u003eThe Agilent 6130B Single Quadrupole Mass Spec w\/ Agilent 1200 MS\/LC System includes:\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eAgilent 6130B Single Quadrupole Mass Spectrometer\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eAgilent MS40+ Rotary Vane Vacuum Pump\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eG1948B ESI Ionization Source\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eG1312B Binary Pump (G1311A Quaternary Pump available, please inquire)\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eG1329A Autosampler\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eG1330B ALS Thermostat\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eG1316A TCC \u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eG1379B Degasser\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eG1315C DAD Detector\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eWindows 11 Professional 64-Bit Data Station with Flatscreen Monitor\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eChemStation Version 4.3 Software Installed\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eAll Power Cords\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eCan\/Crossover Cables\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eAgilent Lan Interface Card Built-In\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eSolvent Tubing\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eCapillaries\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eAgilent 4 Peak Test w\/ Lab Advisor Diagnostics Report \u0026amp; Mass Spec Tuning Report\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eFull 180 Day Parts and Labor Warranty\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"agilent-tests\"\u003e\n\t\t\u003cspan class=\"agilent-tests-title\"\u003eBelow is a List of Diagnostic Tests Performed On This LC System\u003c\/span\u003e\u003cbr\u003e\n\t\t\u003cspan class=\"agilent-tests-header\"\u003eG1315C Diode Array Detector Diagnostic Tests:\u003c\/span\u003e\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003eFilter Test: The test moves the filter into the light path and measures the relative absorbance in the filter position.\u003c\/li\u003e\n\t\t\t\u003cli\u003eDark Current Test: The test measures the dark current from the detector optic.\u003c\/li\u003e\n\t\t\t\u003cli\u003eHolmium Oxide Test: The test measures the Holmium spectrum from the built-in Holmium filter. The spectrum is evaluated for peaks at different wavelengths.\u003c\/li\u003e\n\t\t\t\u003cli\u003eLamp Intensity Test: The test verifies functionality of the UV lamp at various wavelengths.\u003c\/li\u003e\n\t\t\t\u003cli\u003eWavelength Intensity Test: The test confirms the accuracy of wavelengths measured.\u003c\/li\u003e\n\t\t\t\u003cli\u003e Baseline Noise Test: The test measures the amount of baseline noise drift identified by the detector.\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\t\u003cspan class=\"agilent-tests-header\"\u003eG1312B Binary Pump Diagnostic Tests:\u003c\/span\u003e\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003ePressure Test: The pressure test is a quick, built-in test designed to demonstrate the pressure tightness (up to 400 bar) of the system.\u003c\/li\u003e\n\t\t\t\u003cli\u003eLeak Test: The leak test is a built-in troubleshooting designed to demonstrate the leak-tightness of the pump.\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\t\u003cspan class=\"agilent-tests-header\"\u003eG1316A Column Compartment Diagnostic Tests:\u003c\/span\u003e\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003eThermostat Test: Evaluates the cooling and heating performance of the two Peltier elements.\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\t\u003cspan class=\"agilent-tests-header\"\u003eG1329A Autosampler Diagnostic Tests:\u003c\/span\u003e\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e Injector Steps: Performs each movement of the sampling sequence under manual control. This is useful for confirming autosampler functionality.\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\t\u003cspan class=\"agilent-tests-header\"\u003eSystem Tests:\u003c\/span\u003e\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e4 Peak Test (Isocratic Standard): Standard test published by Agilent to confirm complete functionality of the 1200 LC System.\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003ch2\u003eAgilent 6130B Single Quadrupole Mass Spectrometer Specifications\u003c\/h2\u003e\n\t\u003ctable\u003e\n\t\u003ctbody\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tMaximum Scan Speed\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t10,400 Da\/sec\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tSIM Sensitivity, ESI Positive\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tSignal-to-noise ratio \u0026gt; 250:1 (1 pg of reserpine injected on column,\n\t\t\t\u003cbr\u003equantifying the m\/z 609 ion)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tSIM Sensitivity, APCI Positive\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tSignal-to-noise ratio \u0026gt; 100:1 (1 pg of reserpine injected on column,\n\t\t\t\u003cbr\u003equantifying the m\/z 609 ion)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tPolarity Switching\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t30 msec (switching time from positive to negative polarity)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tMass Resolution (Autotune)\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tUnit resolution (full width at half maximum)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tMass Stability\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u0026lt; 0.1 amu or 100 ppm, whichever is larger (over 12 hours)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tMass Accuracy\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t± 0.13 Da\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tMaximum SIM Dwell Time\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t5 msec\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tMaximum SIM Transitions\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t100 (one time segment)\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDynamic Range\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u0026gt; 6 × 10\n\t\t\t\u003csup\u003e6\u003c\/sup\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tMass Range\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t10–3,000 m\/z\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tSingle Point of Control\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tSingle-point data system method capability with full control of Agilent 1200 Series LC Systems and 6100 Series Single Quadrupole LC\/MS Systems\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tTime Programming\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tSIM ion selections, Scan functions, Fragmentor voltage, External CAN valves\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tIonization Sources\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tElectrospray (ESI), Multimode source (simultaneous ESI and APCI), Atmospheric pressure chemical ionization (APCI), ChipCube for intergrated nanoLC, Atmospheric pressure photoionization (APPI)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDetector\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tHigh energy conversion dynode and high gain electron multiplier horn\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tVacuum System\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tOne turbo-molecular pump with one mechanical pump\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDimensions (W x H x D)\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t14 x 18 x 25 in. (35 x 45 x 63.5 cm)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tWeight\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t137.6 lb. (63.4 kg.)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tElectrical Requirements\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t200-230VAC, 60Hz or 200-240VAC, 50Hz\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\t\u003c\/table\u003e\n\t\u003cbr\u003e\n\t\u003cdiv class=\"show-hidden-table\"\u003e\nClick Here to View Specifications for the Agilent 1200 LC System\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\n\t\u003cdiv class=\"hidden-table\"\u003e\n\t\t\u003ctable\u003e\n\t\t\u003ctbody\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cstrong\u003eDAD Detector\u003c\/strong\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cstrong\u003eSpecification\u003c\/strong\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tDetection Type\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t1024-element photodiode array\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tLight Source\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tDeuterium and tungsten lamps\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tWavelength Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t190 - 950 nm\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tShort Term Noise (ASTM) Single and Multi-Wavelength\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t± 0.8 × 10\n\t\t\t\t\u003csup\u003e-5\u003c\/sup\u003e AU at 254 and 750 nm\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tDrift\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t0.9 × 10\n\t\t\t\t\u003csup\u003e-3\u003c\/sup\u003e AU\/hr at 254 nm\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tLinear Absorbance Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u0026gt; 2.0 AU (upper limit)\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tWavelength Accuracy\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t± 1 nm\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tWavelength Bunching\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t1 - 400 nm\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tSlit Width\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t1, 2, 4, 8, 16 nm\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tDiode Width\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u0026lt; 1 nm\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tFlow Cells\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cp\u003e\n\t\t\t\t\tStandard: 13 µL volume, 10 mm cell path length and 120 bar (1740 psi) pressure maximum\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cstrong\u003eBinary Pump\u003c\/strong\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cstrong\u003eSpecification\u003c\/strong\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tHydraulic System\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tTwo dual piston in series pumps with proprietary servo-controlled variable stroke drive, floating piston design and active inlet valve\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tSetable Flow Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t0.001 – 5 ml\/min, in 0.001 ml\/min increments\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tFlow Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cp\u003e\n\t\t\t\t\t0.1 - 5.0 mL\/min\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tFlow Precision\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t≤ 0.07% RSD or ≤ 0.02 min SD, whatever is greater\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tFlow Accuracy\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t± 1% or 10 µl\/min, what ever is greater\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tPressure Operating Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tOperating range 0 to 600 bar (0 – 7800 psi) up to 5 ml\/min\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tPressure Pulsation\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u0026lt; 2 % amplitude (typically \u0026lt; 1 %), at 1 ml\/min isopropanol, at all pressures \u0026gt; 1 MPa\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tCompressibility Compensation\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tUser-selectable, based on mobile phase compressibility\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tRecommended pH Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t1.0 - 12.5\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tGradient Formation\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tHigh-pressure binary mixing\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tDelay Volume\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t600 to 800 µl, dependent on back pressure\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tComposition Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t0 to 100% (1 to 99% or 5 µl\/min per channel, whatever is greater is recommended)\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tComposition Precision\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u0026lt; 0.15% RSD\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tComposition Accuracy\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t± 0.35% absolute\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cstrong\u003eAutosampler\u003c\/strong\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cstrong\u003eSpecification\u003c\/strong\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tInjection Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t0.1 - 100 µl in 0.1 µl increments\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tPrecision\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cp\u003e\n\t\t\t\t\t\u0026lt; 0.25 % RSD of peak areas from 5 to 100 µl\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\t\u003cp\u003e\n\t\t\t\t\t\u0026lt; 1 % RSD of peak areas from 1 to 5 µl\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tPressure Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tOperating range 0 - 60 MPa (0 - 600 bar, 0 - 8850 psi)\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tSample Viscosity Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t0.2 to 50 cp\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tSample Capacity\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t100 × 2 mL vials in 1 tray\n\t\t\t\t\u003cbr\u003e40 × 2 mL vials in ½ tray\u003cbr\u003e15 × 6 mL vials in ½ tray (Agilent vials only)\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tInjection Cycle Time\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t50 s for draw speed 200 µL\/min, ejection speed 200 µL\/min, injection volume 5 µL\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tCarryover\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tTypically \u0026lt; 0.1 %, \u0026lt; 0.05 % with external needle cleaning\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cstrong\u003eALS Thermostat\u003c\/strong\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cstrong\u003eSpecification\u003c\/strong\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tTemperature Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t4°C to 40°C in 1°C increments\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tTemperature Accuracy at Ambient Temperatures \u0026lt; 25°C and Humidity \u0026lt; 50%\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t-1°C to +4°C at a setpoint of 4°C\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tTemperature Accuracy at Ambient Temperatures \u0026gt; 25°C and Humidity \u0026gt; 50%\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t-1°C to +5°C at a setpoint of 4°C\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cstrong\u003eColumn Compartment\u003c\/strong\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cstrong\u003eSpecification\u003c\/strong\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tTemperature Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tAmbient -10°C to 80°C at flow rates up to 5 mL\/min\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tTemperature Stability\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t± 0.15 °C\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tTemperature Accuracy\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t± 0.8°C (± 0.5°C with calibration)\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tColumn Capacity\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tThree 30 cm\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tWarm-Up\/Cool-Down Time\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t5 minutes from ambient to 40°C\n\t\t\t\t\u003cbr\u003e10 minutes from 40°C to 20°C\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tDead Volume\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cp\u003e\n\t\t\t\t\t3 µl left heat exchanger\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\t\u003cp\u003e\n\t\t\t\t\t6 µl right heat exchanger\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cstrong\u003eDegasser\u003c\/strong\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cstrong\u003eSpecification\u003c\/strong\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tNumber of Solvent Channels\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t4\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tMaximum Flow Rate\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t0 - 10 mL\/min per channel\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tInternal Volume Per Channel\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tTypically 12 ml per channel\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tMaterials in Contact with Solvent\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tPTFE, PEEK\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tpH Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t1 - 14\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003c\/tbody\u003e\n\t\t\u003c\/table\u003e\n\t\t\u003cbr\u003e\u003cbr\u003e\n\t\t\u003ctable\u003e\n\t\t\u003ctbody\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd colspan=\"2\"\u003e\n\t\t\t\t\u003ccenter\u003e\n\t\t\t\t\u003cp\u003e\n\t\t\t\t\tComputer Specifications\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\t\u003c\/center\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tProcessor\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tIntel Core I5-8500 CPU\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tRAM\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t32.0 GB\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tHard Drive\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t500GB Internal SSD\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tOperating System\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tWindows 11 Professional, 64-bit\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003c\/tbody\u003e\n\t\t\u003c\/table\u003e\n\t\u003c\/div\u003e\n\t\u003cspan class=\"downloads-header\"\u003eDownloads\u003c\/span\u003e\n\t\u003cdiv class=\"downloads-section\"\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_6130B_Single_Quadrupole_LC-MS_System_-_Marshall_Scientific.pdf?v=1779985730\" target=\"blank\"\u003e\n\t\t\tTechnical Specification Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_6100_Series_Single_Quadrupole_Mass_Spectrometers_Manual_-_Marshall_Scientific.pdf?v=1779985716\" target=\"blank\"\u003e\n\t\t\tOperator's Manual Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_6100_Series_Single_Quadrupole_Mass_Spectrometers_Site_Preparation_Guide_-_Marshall_Scientific.pdf?v=1779985720\" target=\"blank\"\u003e\n\t\t\tSite Prep Guide Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"formalquote2\"\u003e\n\t\t\u003ca class=\"formalquote2link\" href=\"\/formal_quote_a\/2435.htm\" target=\"blank\"\u003eRequest a Formal Quote\u003c\/a\u003e\n\t\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cspan class=\"windows11\"\u003e\u003c\/span\u003e","brand":"My Store","offers":[{"title":"Default Title","offer_id":42474491871322,"sku":"AG-6130LCMS","price":68995.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-6130LCMS-2.jpg?v=1761206310"},{"product_id":"agilent-6140a-single-quadrupole-mass-spectrometer-w-1200-uplc","title":"Agilent 6140A Single Quadrupole Mass Spectrometer w\/ 1200 UPLC","description":"\u003cdiv class=\"productdescriptiontables\"\u003e\n\t\u003ch1\u003eAgilent 6140A Single Quadrupole Mass Spectrometer w\/ 1200 UPLC\u003c\/h1\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-section\"\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eMass Range\u003c\/b\u003e\u003cbr\u003e10 to 1350 m\/z\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eMass Accuracy\u003c\/b\u003e\u003cbr\u003e± 0.13 u\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eScan Speed\u003c\/b\u003e\u003cbr\u003e10,000 u\/s in fast mode and 2500 u\/s in normal mode\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"features-section\"\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cspan class=\"features-header\"\u003eFeatures\u003c\/span\u003e\n\t\t\t\u003cul\u003e\n\t\t\t\t\u003cli\u003eDelivers unmatched analytical performance for routine QC and research applications\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eUltra-fast scanning for high-throughput and fast chromatography applications\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eSimplifies sample preparation and LC method development with exceptional sensitivity\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eFeatures ultrafast ion polarity switching for maximum information from a single injection\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eOrthogonal pneumatic nebulizer reduces chemical noise across diverse LC conditions\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eHigh-capacity solvent drying system supports thermally-sensitive compound analysis\u003c\/li\u003e\n\t\t\t\t\u003cli\u003ePlatinum-plated dielectric capillary enhances sensitivity and optimizes in-source fragmentation\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eMultisignal acquisition supports up to four modes, including polarity switching and SIM\/scan\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eUser-friendly operation through Agilent ChemStation Workstation Software\u003c\/li\u003e\n\t\t\t\u003c\/ul\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/6140A_7a12650e-bc45-4e15-80ce-603fdb204381.jpg?v=1779985737\"\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\n\tThe Agilent 6140A Single Quadrupole Mass Spectrometer w\/ 1200 UPLC delivers unmatched analytical performance and proven day-after-day reliability from routine QC to research applications. This 6140A model brings maximum performance plus ultra-fast scanning for fast chromatography and high-throughput applications. This system allows users to rapidly screen compounds and confirm molecular weights, purify target compounds in complex mixtures, quantitate target compounds, positively identify impurities and more. The Agilent 6140A Single Quadrupole Mass Spectrometer provides unmatched sensitivity, simplifying sample preparation and LC method development. An ultrafast scan speed allows users to take full advantage of UPLC separations, as well as featuring ultrafast ion polarity switching to return maximum information from a single injection, even with narrow LC peaks. The Agilent 6140A Single Quadrupole Mass Spectrometer w\/ 1200 UPLC can be fully controlled from the included Agilent ChemStation Workstation Software, which allows for user-friendly operation in data acquisition, analysis, instrument control, automation, and more.\n\t\u003cbr\u003e\u003cbr\u003e\n\tAdditional high-performance design features of the Agilent 6140A Single Quadrupole Mass Spectrometer include:\n\t\u003cul\u003e\n\t\t\u003cli\u003eOrthogonal pneumatic nebulizer design allows for a wide range of LC conditions by helping to reduce chemical noise. \u003c\/li\u003e\n\t\t\u003cli\u003eHigh-capacity solvent drying system – reduces chemical noise and permits the analysis of thermally-sensitive compounds through user control of gas flow rate and gas temperature.\u003c\/li\u003e\n\t\t\u003cli\u003eResistive capillary for fast switching\u003c\/li\u003e\n\t\t\u003cli\u003eFraction collection capability – can monitor and trigger the collection of fractions based on mass, analog signal input, or time. For mass-based determination, up to 16 m\/z values can be monitored. Requires optional I\/O Accessory Module.\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003cbr\u003e\u003cb\u003eThis turnkey Agilent LC\/MS system was recertified and calibrated by a factory trained engineer and is ready to ship on demand. This system comes with everything needed for easy installation and setup. All of our equipment is fully tested to perform at factory specifications before being shipped.\u003c\/b\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"included-box\"\u003e\n\t\t\u003cspan class=\"included-header\"\u003eINCLUDED:\u003c\/span\u003e\u003cbr\u003eThe Agilent 6140A Single Quadrupole Mass Spectrometer w\/ 1200 UPLC includes:\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eAgilent 6140A Single Quadrupole Mass Spectrometer\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eAgilent MS40+ Rotary Vane Vacuum Pump\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eG1948B ESI Ionization Source\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eG1312B Binary Pump (G1311A Quaternary Pump available, please inquire)\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eG1329A Autosampler\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eG1330B ALS Thermostat\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eG1316A TCC \u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eG1379B Degasser\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eG1315C DAD Detector\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eWindows 11 Professional 64-Bit Data Station with Flatscreen Monitor\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eChemStation Version 4.3 Software Installed\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eAll Power Cords\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eCan\/Crossover Cables\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eAgilent Lan Interface Card Built-In\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eSolvent Tubing\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eCapillaries\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eAgilent 4 Peak Test w\/ Lab Advisor Diagnostics Report \u0026amp; Mass Spec Tuning Report\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eFull 180 Day Parts and Labor Warranty\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"agilent-tests\"\u003e\n\t\t\u003cspan class=\"agilent-tests-title\"\u003eBelow is a List of Diagnostic Tests Performed On This LC System\u003c\/span\u003e\u003cbr\u003e\n\t\t\u003cspan class=\"agilent-tests-header\"\u003eG1315C Diode Array Detector Diagnostic Tests:\u003c\/span\u003e\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003eFilter Test: The test moves the filter into the light path and measures the relative absorbance in the filter position.\u003c\/li\u003e\n\t\t\t\u003cli\u003eDark Current Test: The test measures the dark current from the detector optic.\u003c\/li\u003e\n\t\t\t\u003cli\u003eHolmium Oxide Test: The test measures the Holmium spectrum from the built-in Holmium filter. The spectrum is evaluated for peaks at different wavelengths.\u003c\/li\u003e\n\t\t\t\u003cli\u003eLamp Intensity Test: The test verifies functionality of the UV lamp at various wavelengths.\u003c\/li\u003e\n\t\t\t\u003cli\u003eWavelength Intensity Test: The test confirms the accuracy of wavelengths measured.\u003c\/li\u003e\n\t\t\t\u003cli\u003e Baseline Noise Test: The test measures the amount of baseline noise drift identified by the detector.\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\t\u003cspan class=\"agilent-tests-header\"\u003eG1312B Binary Pump Diagnostic Tests:\u003c\/span\u003e\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003ePressure Test: The pressure test is a quick, built-in test designed to demonstrate the pressure tightness (up to 400 bar) of the system.\u003c\/li\u003e\n\t\t\t\u003cli\u003eLeak Test: The leak test is a built-in troubleshooting designed to demonstrate the leak-tightness of the pump.\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\t\u003cspan class=\"agilent-tests-header\"\u003eG1316A Column Compartment Diagnostic Tests:\u003c\/span\u003e\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003eThermostat Test: Evaluates the cooling and heating performance of the two Peltier elements.\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\t\u003cspan class=\"agilent-tests-header\"\u003eG1329A Autosampler Diagnostic Tests:\u003c\/span\u003e\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e Injector Steps: Performs each movement of the sampling sequence under manual control. This is useful for confirming autosampler functionality.\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\t\u003cspan class=\"agilent-tests-header\"\u003eSystem Tests:\u003c\/span\u003e\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e4 Peak Test (Isocratic Standard): Standard test published by Agilent to confirm complete functionality of the 1200 LC System.\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003ch2\u003eAgilent 6140A Single Quadrupole Mass Spectrometer Specifications\u003c\/h2\u003e\n\t\u003ctable\u003e\n\t\u003ctbody\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tMass Range\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t10 – 1350 m\/z\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tMass Accuracy\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t± 0.13 u within the calibrated mass range in scan mode\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tMass Axis Stability\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tThe mass drift does not exceed the larger absolute value of ± 0.1 Da or ± 100 ppm of measured mass over a 12 hour period at constant temperature ± 3 degrees centrigrade.\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tScan Speed\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t10,000 u\/s in fast mode and 2500 u\/s in normal mode\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tSIM Sensitivity\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tESI at 400 μ\/min or APCI at 1000 μ\/min\n\t\t\t\t\u003cbr\u003e Selected ion monitoring of m\/z 609.3\u003cbr\u003e Positive ionization\u003cbr\u003e 1 pg reserpine, 100:1 RMS (20:1 peak-to-peak)\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tScan Sensitivity\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tESI at 400 μ\/min or APCI at 1000 μ\/min\n\t\t\t\t\u003cbr\u003e Scan range m\/z 100 – 650\u003cbr\u003e Scan speed 2500 u\/s\u003cbr\u003e Extracted ion at m\/z 609.3\u003cbr\u003e Positive ionization\u003cbr\u003e 50 pg reserpine, 100:1 RMS (20:1 peak-to-peak)\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tFlow Rate\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tESI: Up to 1.0 ml\/min water without a flow splitter\n\t\t\t\t\u003cbr\u003e APCI: Up to 1.5 ml\/min water without a flow splitter\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tMultisignal acquisition\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tAbility to cycle through four acquisition modes on a scan-by-scan basis within a single run. Up to four analysis modes can be viewed in the software window and can be linked together to facilitate processing and analysis. Modes of operation: positive\/negative polarity switching, variable fragmentor voltage selection, and concurrent SIM\/scan.\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tOperating Conditions\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tTemperature range: 15 °C to 35 °C (59 °F to 95 °F)\n\t\t\t\t\u003cbr\u003e Relative humidity: less than 95 % (non-condensing)\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tDimensions\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tHeight: 65 cm (26 in)\n\t\t\t\t\u003cbr\u003e Width: 39 cm (15 in)\u003cbr\u003e Depth: 75 cm (29 in)\u003cbr\u003e Weight: 50 kg (110 pounds)\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tElectrical Requirements\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t200-240V, 50\/60Hz\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\t\u003c\/table\u003e\n\t\u003cbr\u003e\n\t\u003cdiv class=\"show-hidden-table\"\u003e\nClick Here to View Specifications for the Agilent 1200 LC System\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\n\t\u003cdiv class=\"hidden-table\"\u003e\n\t\t\u003ctable\u003e\n\t\t\u003ctbody\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cstrong\u003eDAD Detector\u003c\/strong\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cstrong\u003eSpecification\u003c\/strong\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tDetection Type\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t1024-element photodiode array\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tLight Source\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tDeuterium and tungsten lamps\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tWavelength Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t190 - 950 nm\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tShort Term Noise (ASTM) Single and Multi-Wavelength\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t± 0.8 × 10\n\t\t\t\t\u003csup\u003e-5\u003c\/sup\u003e AU at 254 and 750 nm\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tDrift\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t0.9 × 10\n\t\t\t\t\u003csup\u003e-3\u003c\/sup\u003e AU\/hr at 254 nm\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tLinear Absorbance Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u0026gt; 2.0 AU (upper limit)\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tWavelength Accuracy\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t± 1 nm\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tWavelength Bunching\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t1 - 400 nm\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tSlit Width\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t1, 2, 4, 8, 16 nm\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tDiode Width\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u0026lt; 1 nm\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tFlow Cells\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cp\u003e\n\t\t\t\t\tStandard: 13 µL volume, 10 mm cell path length and 120 bar (1740 psi) pressure maximum\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cstrong\u003eBinary Pump\u003c\/strong\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cstrong\u003eSpecification\u003c\/strong\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tHydraulic System\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tTwo dual piston in series pumps with proprietary servo-controlled variable stroke drive, floating piston design and active inlet valve\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tSetable Flow Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t0.001 – 5 ml\/min, in 0.001 ml\/min increments\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tFlow Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cp\u003e\n\t\t\t\t\t0.1 - 5.0 mL\/min\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tFlow Precision\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t≤ 0.07% RSD or ≤ 0.02 min SD, whatever is greater\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tFlow Accuracy\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t± 1% or 10 µl\/min, what ever is greater\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tPressure Operating Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tOperating range 0 to 600 bar (0 – 7800 psi) up to 5 ml\/min\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tPressure Pulsation\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u0026lt; 2 % amplitude (typically \u0026lt; 1 %), at 1 ml\/min isopropanol, at all pressures \u0026gt; 1 MPa\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tCompressibility Compensation\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tUser-selectable, based on mobile phase compressibility\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tRecommended pH Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t1.0 - 12.5\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tGradient Formation\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tHigh-pressure binary mixing\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tDelay Volume\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t600 to 800 µl, dependent on back pressure\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tComposition Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t0 to 100% (1 to 99% or 5 µl\/min per channel, whatever is greater is recommended)\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tComposition Precision\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u0026lt; 0.15% RSD\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tComposition Accuracy\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t± 0.35% absolute\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cstrong\u003eAutosampler\u003c\/strong\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cstrong\u003eSpecification\u003c\/strong\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tInjection Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t0.1 - 100 µl in 0.1 µl increments\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tPrecision\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cp\u003e\n\t\t\t\t\t\u0026lt; 0.25 % RSD of peak areas from 5 to 100 µl\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\t\u003cp\u003e\n\t\t\t\t\t\u0026lt; 1 % RSD of peak areas from 1 to 5 µl\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tPressure Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tOperating range 0 - 60 MPa (0 - 600 bar, 0 - 8850 psi)\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tSample Viscosity Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t0.2 to 50 cp\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tSample Capacity\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t100 × 2 mL vials in 1 tray\n\t\t\t\t\u003cbr\u003e40 × 2 mL vials in ½ tray\u003cbr\u003e15 × 6 mL vials in ½ tray (Agilent vials only)\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tInjection Cycle Time\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t50 s for draw speed 200 µL\/min, ejection speed 200 µL\/min, injection volume 5 µL\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tCarryover\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tTypically \u0026lt; 0.1 %, \u0026lt; 0.05 % with external needle cleaning\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cstrong\u003eALS Thermostat\u003c\/strong\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cstrong\u003eSpecification\u003c\/strong\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tTemperature Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t4°C to 40°C in 1°C increments\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tTemperature Accuracy at Ambient Temperatures \u0026lt; 25°C and Humidity \u0026lt; 50%\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t-1°C to +4°C at a setpoint of 4°C\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tTemperature Accuracy at Ambient Temperatures \u0026gt; 25°C and Humidity \u0026gt; 50%\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t-1°C to +5°C at a setpoint of 4°C\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cstrong\u003eColumn Compartment\u003c\/strong\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cstrong\u003eSpecification\u003c\/strong\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tTemperature Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tAmbient -10°C to 80°C at flow rates up to 5 mL\/min\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tTemperature Stability\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t± 0.15 °C\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tTemperature Accuracy\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t± 0.8°C (± 0.5°C with calibration)\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tColumn Capacity\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tThree 30 cm\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tWarm-Up\/Cool-Down Time\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t5 minutes from ambient to 40°C\n\t\t\t\t\u003cbr\u003e10 minutes from 40°C to 20°C\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tDead Volume\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cp\u003e\n\t\t\t\t\t3 µl left heat exchanger\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\t\u003cp\u003e\n\t\t\t\t\t6 µl right heat exchanger\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cstrong\u003eDegasser\u003c\/strong\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cstrong\u003eSpecification\u003c\/strong\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tNumber of Solvent Channels\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t4\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tMaximum Flow Rate\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t0 - 10 mL\/min per channel\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tInternal Volume Per Channel\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tTypically 12 ml per channel\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tMaterials in Contact with Solvent\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tPTFE, PEEK\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tpH Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t1 - 14\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003c\/tbody\u003e\n\t\t\u003c\/table\u003e\n\t\t\u003cbr\u003e\u003cbr\u003e\n\t\t\u003ctable\u003e\n\t\t\u003ctbody\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd colspan=\"2\"\u003e\n\t\t\t\t\u003ccenter\u003e\n\t\t\t\t\u003cp\u003e\n\t\t\t\t\tComputer Specifications\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\t\u003c\/center\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tProcessor\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tIntel Core I5-8500 CPU\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tRAM\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t32.0 GB\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tHard Drive\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t500GB Internal SSD\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tOperating System\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tWindows 11 Professional, 64-bit\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003c\/tbody\u003e\n\t\t\u003c\/table\u003e\n\t\u003c\/div\u003e\n\t\u003cspan class=\"downloads-header\"\u003eDownloads\u003c\/span\u003e\n\t\u003cdiv class=\"downloads-section\"\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_6140A_Single_Quadrupole_Mass_Spectrometer_-_Marshall_Scientific.pdf?v=1779985740\" target=\"blank\"\u003e\n\t\t\tTechnical Specification Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_6100_Series_Single_Quadrupole_Mass_Spectrometers_Manual_-_Marshall_Scientific.pdf?v=1779985716\" target=\"blank\"\u003e\n\t\t\tOperator's Manual Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_6100_Series_Single_Quadrupole_Mass_Spectrometers_Site_Preparation_Guide_-_Marshall_Scientific.pdf?v=1779985720\" target=\"blank\"\u003e\n\t\t\tSite Prep Guide Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"formalquote2\"\u003e\n\t\t\u003ca class=\"formalquote2link\" href=\"\/formal_quote_a\/2514.htm\" target=\"blank\"\u003eRequest a Formal Quote\u003c\/a\u003e\n\t\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cspan class=\"windows11\"\u003e\u003c\/span\u003e","brand":"My Store","offers":[{"title":"Default Title","offer_id":42474492395610,"sku":"AG-6140A","price":74995.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-6140A-2.jpg?v=1761206417"},{"product_id":"agilent-6140a-single-quadrupole-mass-spectrometer-w-1260-infinity-i-lc-system","title":"Agilent 6140A Single Quadrupole Mass Spectrometer w\/ 1260 Infinity I LC System","description":"\u003cdiv class=\"productdescriptiontables\"\u003e\n\t\u003ch1\u003eAgilent 6140A Single Quadrupole Mass Spectrometer w\/ 1260 Infinity I LC System\u003c\/h1\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-section\"\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eMass Range\u003c\/b\u003e\u003cbr\u003e10 to 1350 m\/z\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eMass Accuracy\u003c\/b\u003e\u003cbr\u003e± 0.13 u\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eScan Speed\u003c\/b\u003e\u003cbr\u003e10,000 u\/s in fast mode and 2500 u\/s in normal mode\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"features-section\"\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cspan class=\"features-header\"\u003eFeatures\u003c\/span\u003e\n\t\t\t\u003cul\u003e\n\t\t\t\t\u003cli\u003eDelivers unmatched analytical performance for routine QC and research applications\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eUltra-fast scanning for high-throughput and fast chromatography applications\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eSimplifies sample preparation and LC method development with exceptional sensitivity\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eFeatures ultrafast ion polarity switching for maximum information from a single injection\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eOrthogonal pneumatic nebulizer reduces chemical noise across diverse LC conditions\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eHigh-capacity solvent drying system supports thermally-sensitive compound analysis\u003c\/li\u003e\n\t\t\t\t\u003cli\u003ePlatinum-plated dielectric capillary enhances sensitivity and optimizes in-source fragmentation\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eMultisignal acquisition supports up to four modes, including polarity switching and SIM\/scan\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eUser-friendly operation through Agilent ChemStation Workstation Software\u003c\/li\u003e\n\t\t\t\u003c\/ul\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/6140A_7a12650e-bc45-4e15-80ce-603fdb204381.jpg?v=1779985737\"\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\n\tThe Agilent 6140A Single Quadrupole Mass Spectrometer w\/ 1260 Infinity I LC System delivers unmatched analytical performance and proven day-after-day reliability from routine QC to research applications. This 6140A model brings maximum performance plus ultra-fast scanning for fast chromatography and high-throughput applications. This system allows users to rapidly screen compounds and confirm molecular weights, purify target compounds in complex mixtures, quantitate target compounds, positively identify impurities and more. The Agilent 6140A Single Quadrupole Mass Spectrometer provides unmatched sensitivity, simplifying sample preparation and LC method development. An ultrafast scan speed allows users to take full advantage of LC separations, as well as featuring ultrafast ion polarity switching to return maximum information from a single injection, even with narrow LC peaks. Agilent 6140A Single Quadrupole Mass Spectrometer w\/ 1260 Infinity I LC System can be fully controlled from the included Agilent ChemStation Workstation Software, which allows for user-friendly operation in data acquisition, analysis, instrument control, automation, and more.\n\t\u003cbr\u003e\u003cbr\u003e\n\tAdditional high-performance design features of the Agilent 6140A Single Quadrupole Mass Spectrometer include:\n\t\u003cul\u003e\n\t\t\u003cli\u003eOrthogonal pneumatic nebulizer design allows for a wide range of LC conditions by helping to reduce chemical noise. \u003c\/li\u003e\n\t\t\u003cli\u003eHigh-capacity solvent drying system – reduces chemical noise and permits the analysis of thermally-sensitive compounds through user control of gas flow rate and gas temperature.\u003c\/li\u003e\n\t\t\u003cli\u003eResistive capillary for fast switching\u003c\/li\u003e\n\t\t\u003cli\u003eFraction collection capability – can monitor and trigger the collection of fractions based on mass, analog signal input, or time. For mass-based determination, up to 16 m\/z values can be monitored. Requires optional I\/O Accessory Module.\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003cbr\u003e\u003cb\u003eThis turnkey Agilent LC\/MS system was recertified and calibrated by a factory trained engineer and is ready to ship on demand. This system comes with everything needed for easy installation and setup. All of our equipment is fully tested to perform at factory specifications before being shipped.\u003c\/b\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"included-box\"\u003e\n\t\t\u003cspan class=\"included-header\"\u003eINCLUDED:\u003c\/span\u003e\u003cbr\u003eThe Agilent 6140A Single Quadrupole Mass Spectrometer w\/ 1260 Infinity I LC System includes:\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eAgilent 6140A Single Quadrupole Mass Spectrometer\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eAgilent MS40+ Rotary Vane Vacuum Pump\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eG1948B ESI Ionization Source\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eG1312B Binary Pump (G1311B Quaternary Pump available, please inquire)\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eG1329B Autosampler\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eG1330B ALS Thermostat\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eG1316A TCC \u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eG1379B Degasser\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eG4212B DAD Detector\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eWindows 11 Professional 64-Bit Data Station with Flatscreen Monitor\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eChemStation Version 4.3 Software Installed\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eAll Power Cords\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eCan\/Crossover Cables\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eAgilent Lan Interface Card Built-In\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eSolvent Tubing\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eCapillaries\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eAgilent 4 Peak Test w\/ Lab Advisor Diagnostics Report \u0026amp; Mass Spec Tuning Report\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eFull 180 Day Parts and Labor Warranty\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"agilent-tests\"\u003e\n\t\t\u003cspan class=\"agilent-tests-title\"\u003eBelow is a List of Diagnostic Tests Performed On This LC System\u003c\/span\u003e\u003cbr\u003e\n\t\t\u003cspan class=\"agilent-tests-header\"\u003eG4212B Diode Array Detector Diagnostic Tests:\u003c\/span\u003e\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003eFilter Test: The test moves the filter into the light path and measures the relative absorbance in the filter position.\u003c\/li\u003e\n\t\t\t\u003cli\u003eDark Current Test: The test measures the dark current from the detector optic.\u003c\/li\u003e\n\t\t\t\u003cli\u003eHolmium Oxide Test: The test measures the Holmium spectrum from the built-in Holmium filter. The spectrum is evaluated for peaks at different wavelengths.\u003c\/li\u003e\n\t\t\t\u003cli\u003eLamp Intensity Test: The test verifies functionality of the UV lamp at various wavelengths.\u003c\/li\u003e\n\t\t\t\u003cli\u003eWavelength Intensity Test: The test confirms the accuracy of wavelengths measured.\u003c\/li\u003e\n\t\t\t\u003cli\u003e Baseline Noise Test: The test measures the amount of baseline noise drift identified by the detector.\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\t\u003cspan class=\"agilent-tests-header\"\u003eG1312B Binary Pump Diagnostic Tests:\u003c\/span\u003e\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003ePressure Test: The pressure test is a quick, built-in test designed to demonstrate the pressure tightness (up to 400 bar) of the system.\u003c\/li\u003e\n\t\t\t\u003cli\u003eLeak Test: The leak test is a built-in troubleshooting designed to demonstrate the leak-tightness of the pump.\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\t\u003cspan class=\"agilent-tests-header\"\u003eG1316A Column Compartment Diagnostic Tests:\u003c\/span\u003e\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003eThermostat Test: Evaluates the cooling and heating performance of the two Peltier elements.\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\t\u003cspan class=\"agilent-tests-header\"\u003eG1329B Autosampler Diagnostic Tests:\u003c\/span\u003e\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e Injector Steps: Performs each movement of the sampling sequence under manual control. This is useful for confirming autosampler functionality.\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\t\u003cspan class=\"agilent-tests-header\"\u003eSystem Tests:\u003c\/span\u003e\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e4 Peak Test (Isocratic Standard): Standard test published by Agilent to confirm complete functionality of the 1260 Infinity I LC System.\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003ch2\u003eAgilent 6140A Single Quadrupole Mass Spectrometer Specifications\u003c\/h2\u003e\n\t\u003ctable\u003e\n\t\u003ctbody\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tMass Range\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t10 – 1350 m\/z\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tMass Accuracy\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t± 0.13 u within the calibrated mass range in scan mode\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tMass Axis Stability\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tThe mass drift does not exceed the larger absolute value of ± 0.1 Da or ± 100 ppm of measured mass over a 12 hour period at constant temperature ± 3 degrees centrigrade.\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tScan Speed\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t10,000 u\/s in fast mode and 2500 u\/s in normal mode\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tSIM Sensitivity\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tESI at 400 μ\/min or APCI at 1000 μ\/min\n\t\t\t\t\u003cbr\u003e Selected ion monitoring of m\/z 609.3\u003cbr\u003e Positive ionization\u003cbr\u003e 1 pg reserpine, 100:1 RMS (20:1 peak-to-peak)\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tScan Sensitivity\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tESI at 400 μ\/min or APCI at 1000 μ\/min\n\t\t\t\t\u003cbr\u003e Scan range m\/z 100 – 650\u003cbr\u003e Scan speed 2500 u\/s\u003cbr\u003e Extracted ion at m\/z 609.3\u003cbr\u003e Positive ionization\u003cbr\u003e 50 pg reserpine, 100:1 RMS (20:1 peak-to-peak)\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tFlow Rate\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tESI: Up to 1.0 ml\/min water without a flow splitter\n\t\t\t\t\u003cbr\u003e APCI: Up to 1.5 ml\/min water without a flow splitter\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tMultisignal acquisition\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tAbility to cycle through four acquisition modes on a scan-by-scan basis within a single run. Up to four analysis modes can be viewed in the software window and can be linked together to facilitate processing and analysis. Modes of operation: positive\/negative polarity switching, variable fragmentor voltage selection, and concurrent SIM\/scan.\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tOperating Conditions\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tTemperature range: 15 °C to 35 °C (59 °F to 95 °F)\n\t\t\t\t\u003cbr\u003e Relative humidity: less than 95 % (non-condensing)\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tDimensions\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tHeight: 65 cm (26 in)\n\t\t\t\t\u003cbr\u003e Width: 39 cm (15 in)\u003cbr\u003e Depth: 75 cm (29 in)\u003cbr\u003e Weight: 50 kg (110 pounds)\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tElectrical Requirements\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t200-240V, 50\/60Hz\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\t\u003c\/table\u003e\n\t\u003cbr\u003e\n\t\u003cdiv class=\"show-hidden-table\"\u003e\nClick Here to View Specifications for the Agilent 1260 Infinity I LC System\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\n\t\u003cdiv class=\"hidden-table\"\u003e\n\t\t\u003ctable\u003e\n\t\t\u003ctbody\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cstrong\u003eDAD Detector\u003c\/strong\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cstrong\u003eSpecification\u003c\/strong\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tDetection Type\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t1024-element photodiode array\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tLight Source\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tDeuterium and tungsten lamps\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tWavelength Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t190 - 640 nm\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tShort Term Noise (ASTM) Single and Multi-Wavelength\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t± 3 × 10 \n\t\t\t\t\u003csup\u003e-6\u003c\/sup\u003e AU at 230 nm\/4 nm\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tDrift\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u0026lt; 0.5 × 10 \n\t\t\t\t\u003csup\u003e-3\u003c\/sup\u003e AU\/hr at 230 nm\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tLinear Absorbance Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u0026gt; 2.0 AU (5%) at 265 nm\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tWavelength Accuracy\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t± 1 nm\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tWavelength Bunching\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t1 - 400 nm\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tSlit Width\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t4 nm\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tDiode Width\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t~ 0.5 nm\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tFlow Cell\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cp\u003e\n\t\t\t\t\tStandard: 13 µL volume, 10 mm cell path length and 120 bar (1740 psi) pressure maximum\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cstrong\u003eBinary Pump\u003c\/strong\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cstrong\u003eSpecification\u003c\/strong\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tHydraulic System\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tTwo dual piston in series pumps with proprietary servo-controlled variable stroke drive, power transmission by gears and ball screws, floating pistons\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tSetable Flow Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t0.001 – 5 ml\/min, in 0.001 ml\/min increments\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tFlow Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cp\u003e\n\t\t\t\t\t0.5 - 5.0 mL\/min\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tFlow Precision\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t≤ 0.07% RSD or ≤ 0.02 min SD, whatever is greater\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tFlow Accuracy\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t± 1% or 10 µl\/min, what ever is greater\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tPressure Operating Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tOperating range 0 to 600 bar (0 – 7800 psi) up to 5 ml\/min\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tPressure Pulsation\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u0026lt; 2 % amplitude (typically \u0026lt; 1.3 %), or \u0026lt; 0.3 MPa (3 bar), whatever is greater, at 1 mL\/min isopropanol, at all pressures \u0026gt; 1 MPa (10 bar, 147 psi)\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tCompressibility Compensation\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tUser-selectable, based on mobile phase compressibility\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tRecommended pH Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t1.0 - 12.5, solvents with pH \u0026lt; 2.3 should not contain acids which attack stainless stee\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tGradient Formation\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tHigh-pressure binary mixing\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tDelay Volume\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t600 to 800 µl, dependent on back pressure\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tComposition Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t0 to 100% (1 to 99% or 5 µl\/min per channel, whatever is greater is recommended)\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tComposition Precision\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u0026lt; 0.15% RSD or \u0026lt; 0.04 min SD whatever is greater\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tComposition Accuracy\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t± 0.35% absolute at 2 mL\/min, at 10 MPa (100 bar)\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cstrong\u003eAutosampler\u003c\/strong\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cstrong\u003eSpecification\u003c\/strong\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tInjection Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t0.1 - 100 µl in 0.1 µl increments\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tPrecision\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cp\u003e\n\t\t\t\t\t\u0026lt; 0.25 % RSD of peak areas from 5 to 100 µl\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\t\u003cp\u003e\n\t\t\t\t\t\u0026lt; 1 % RSD of peak areas from 1 to 5 µl\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tPressure Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tOperating range 0 - 60 MPa (0 - 600 bar, 0 - 8850 psi)\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tSample Viscosity Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t0.2 to 50 cp\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tSample Capacity\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t100 × 2 mL vials in 1 tray\n\t\t\t\t\u003cbr\u003e40 × 2 mL vials in ½ tray\u003cbr\u003e15 × 6 mL vials in ½ tray (Agilent vials only)\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tInjection Cycle Time\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t50 s for draw speed 200 µL\/min, ejection speed 200 µL\/min, injection volume 5 µL\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tCarryover\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tTypically \u0026lt; 0.1 %, \u0026lt; 0.05 % with external needle cleaning\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cstrong\u003eALS Thermostat\u003c\/strong\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cstrong\u003eSpecification\u003c\/strong\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tTemperature Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t4°C to 40°C in 1°C increments\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tTemperature Accuracy at Ambient Temperatures \u0026lt; 25°C and Humidity \u0026lt; 50%\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t3°C to +8°C at a setpoint of 4°C\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tTemperature Accuracy at Ambient Temperatures \u0026gt; 30°C and Humidity \u0026gt; 60%\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t3°C to +9°C at a setpoint of 4°C\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cstrong\u003eColumn Compartment\u003c\/strong\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cstrong\u003eSpecification\u003c\/strong\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tTemperature Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tAmbient -10°C to 80°C at flow rates up to 5 mL\/min\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tTemperature Stability\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t± 0.15 °C\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tTemperature Accuracy\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t± 0.8°C (± 0.5°C with calibration)\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tColumn Capacity\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tThree 30 cm\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tWarm-Up\/Cool-Down Time\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t5 minutes from ambient to 40°C\n\t\t\t\t\u003cbr\u003e10 minutes from 40°C to 20°C\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tDead Volume\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cp\u003e\n\t\t\t\t\t3 µl left heat exchanger\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\t\u003cp\u003e\n\t\t\t\t\t6 µl right heat exchanger\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cstrong\u003eDegasser\u003c\/strong\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cstrong\u003eSpecification\u003c\/strong\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tNumber of Solvent Channels\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t4\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tMaximum Flow Rate\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t0 - 5 mL\/min per channel\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tInternal Volume Per Channel\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tTypically 1 ml per channel\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tMaterials in Contact with Solvent\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tPTFE, PEEK\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tpH Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t1 - 14\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003c\/tbody\u003e\n\t\t\u003c\/table\u003e\n\t\t\u003cbr\u003e\u003cbr\u003e\n\t\t\u003ctable\u003e\n\t\t\u003ctbody\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd colspan=\"2\"\u003e\n\t\t\t\t\u003ccenter\u003e\n\t\t\t\t\u003cp\u003e\n\t\t\t\t\tComputer Specifications\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\t\u003c\/center\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tProcessor\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tIntel Core I5-8500 CPU\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tRAM\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t32.0 GB\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tHard Drive\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t500GB Internal SSD\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tOperating System\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tWindows 11 Professional, 64-bit\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003c\/tbody\u003e\n\t\t\u003c\/table\u003e\n\t\u003c\/div\u003e\n\t\u003cspan class=\"downloads-header\"\u003eDownloads\u003c\/span\u003e\n\t\u003cdiv class=\"downloads-section\"\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_6140A_Single_Quadrupole_Mass_Spectrometer_-_Marshall_Scientific.pdf?v=1779985740\" target=\"blank\"\u003e\n\t\t\tTechnical Specification Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_6100_Series_Single_Quadrupole_Mass_Spectrometers_Manual_-_Marshall_Scientific.pdf?v=1779985716\" target=\"blank\"\u003e\n\t\t\tOperator's Manual Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_6100_Series_Single_Quadrupole_Mass_Spectrometers_Site_Preparation_Guide_-_Marshall_Scientific.pdf?v=1779985720\" target=\"blank\"\u003e\n\t\t\tSite Prep Guide Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"formalquote2\"\u003e\n\t\t\u003ca class=\"formalquote2link\" href=\"\/formal_quote_a\/2846.htm\" target=\"blank\"\u003eRequest a Formal Quote\u003c\/a\u003e\n\t\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cspan class=\"windows11\"\u003e\u003c\/span\u003e","brand":"My Store","offers":[{"title":"Default Title","offer_id":42474493214810,"sku":"AG-6140A1260","price":88595.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-6140A1260-2.jpg?v=1761206445"},{"product_id":"agilent-6140a-single-quadrupole-mass-spectrometer","title":"Agilent 6140A Single Quadrupole Mass Spectrometer","description":"\u003cdiv class=\"productdescriptiontables\"\u003e\n\t\u003ch1\u003eAgilent 6140A Single Quadrupole Mass Spectrometer\u003c\/h1\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-section\"\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eMass Range\u003c\/b\u003e\u003cbr\u003e10 to 1350 m\/z\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eMass Accuracy\u003c\/b\u003e\u003cbr\u003e± 0.13 u\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eScan Speed\u003c\/b\u003e\u003cbr\u003e10,000 u\/s in fast mode and 2500 u\/s in normal mode\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"features-section\"\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cspan class=\"features-header\"\u003eFeatures\u003c\/span\u003e\n\t\t\t\u003cul\u003e\n\t\t\t\t\u003cli\u003eDelivers unmatched analytical performance for routine QC and research applications\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eUltra-fast scanning for high-throughput\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eSimplifies sample preparation with exceptional sensitivity\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eFeatures ultrafast ion polarity switching for maximum information from a single injection\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eOrthogonal pneumatic nebulizer reduces chemical noise across diverse LC conditions\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eHigh-capacity solvent drying system supports thermally-sensitive compound analysis\u003c\/li\u003e\n\t\t\t\t\u003cli\u003ePlatinum-plated dielectric capillary enhances sensitivity and optimizes in-source fragmentation\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eMultisignal acquisition supports up to four modes, including polarity switching and SIM\/scan\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eUser-friendly operation through Agilent ChemStation Workstation Software\u003c\/li\u003e\n\t\t\t\u003c\/ul\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/6140A_7a12650e-bc45-4e15-80ce-603fdb204381.jpg?v=1779985737\"\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\n\tThe Agilent 6140A Single Quadrupole Mass Spectrometer delivers unmatched analytical performance and proven day-after-day reliability from routine QC to research applications. This 6140A model brings maximum performance plus ultra-fast scanning for fast chromatography and high-throughput applications. This system allows users to rapidly screen compounds and confirm molecular weights, purify target compounds in complex mixtures, quantitate target compounds, positively identify impurities and more. The Agilent 6140A Single Quadrupole Mass Spectrometer provides unmatched sensitivity, simplifying sample preparation. An ultrafast scan speed allows users to take full advantage of LC separations when paired with an Agilent LC System, as well as featuring ultrafast ion polarity switching to return maximum information from a single injection, even with narrow LC peaks. Agilent 6140A Single Quadrupole Mass Spectrometer  can be fully controlled from the included Agilent ChemStation Workstation Software, which allows for user-friendly operation in data acquisition, analysis, instrument control, automation, and more.\n\t\u003cbr\u003e\u003cbr\u003e\n\tAdditional high-performance design features of the Agilent 6140A Single Quadrupole Mass Spectrometer include:\n\t\u003cul\u003e\n\t\t\u003cli\u003eOrthogonal pneumatic nebulizer design allows for a wide range of LC conditions by helping to reduce chemical noise. \u003c\/li\u003e\n\t\t\u003cli\u003eHigh-capacity solvent drying system – reduces chemical noise and permits the analysis of thermally-sensitive compounds through user control of gas flow rate and gas temperature.\u003c\/li\u003e\n\t\t\u003cli\u003eResistive capillary for fast switching\u003c\/li\u003e\n\t\t\u003cli\u003eFraction collection capability – can monitor and trigger the collection of fractions based on mass, analog signal input, or time. For mass-based determination, up to 16 m\/z values can be monitored. Requires optional I\/O Accessory Module.\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003cbr\u003e\u003cb\u003eThis Agilent MS system was recertified and calibrated by a factory trained engineer and is ready to ship on demand. This system comes with everything needed for easy installation and setup. All of our equipment is fully tested to perform at factory specifications before being shipped.\u003c\/b\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"included-box\"\u003e\n\t\t\u003cspan class=\"included-header\"\u003eINCLUDED:\u003c\/span\u003e\u003cbr\u003eThe Agilent 6140A Single Quadrupole Mass Spectrometer includes:\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eAgilent 6140A Single Quadrupole Mass Spectrometer\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003e Agilent MS40+ Rotary Vane Vacuum Pump\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eG1948B ESI Ionization Source\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eWindows 11 Professional 64-Bit Data Station with Flatscreen Monitor\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eChemStation Version 4.3 Software Installed\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eAll Power Cords\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eCan\/Crossover Cables\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eLab Advisor Diagnostics Report \u0026amp; Mass Spec Tuning Report\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eFull 180 Day Parts and Labor Warranty\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003ch2\u003eAgilent 6140A Single Quadrupole Mass Spectrometer Specifications\u003c\/h2\u003e\n\t\u003ctable\u003e\n\t\u003ctbody\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tMass Range\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t10 – 1350 m\/z\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tMass Accuracy\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t± 0.13 u within the calibrated mass range in scan mode\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tMass Axis Stability\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tThe mass drift does not exceed the larger absolute value of ± 0.1 Da or ± 100 ppm of measured mass over a 12 hour period at constant temperature ± 3 degrees centrigrade.\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tScan Speed\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t10,000 u\/s in fast mode and 2500 u\/s in normal mode\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tSIM Sensitivity\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tESI at 400 μ\/min or APCI at 1000 μ\/min\n\t\t\t\t\u003cbr\u003e Selected ion monitoring of m\/z 609.3\u003cbr\u003e Positive ionization\u003cbr\u003e 1 pg reserpine, 100:1 RMS (20:1 peak-to-peak)\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tScan Sensitivity\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tESI at 400 μ\/min or APCI at 1000 μ\/min\n\t\t\t\t\u003cbr\u003e Scan range m\/z 100 – 650\u003cbr\u003e Scan speed 2500 u\/s\u003cbr\u003e Extracted ion at m\/z 609.3\u003cbr\u003e Positive ionization\u003cbr\u003e 50 pg reserpine, 100:1 RMS (20:1 peak-to-peak)\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tFlow Rate\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tESI: Up to 1.0 ml\/min water without a flow splitter\n\t\t\t\t\u003cbr\u003e APCI: Up to 1.5 ml\/min water without a flow splitter\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tMultisignal acquisition\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tAbility to cycle through four acquisition modes on a scan-by-scan basis within a single run. Up to four analysis modes can be viewed in the software window and can be linked together to facilitate processing and analysis. Modes of operation: positive\/negative polarity switching, variable fragmentor voltage selection, and concurrent SIM\/scan.\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tOperating Conditions\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tTemperature range: 15 °C to 35 °C (59 °F to 95 °F)\n\t\t\t\t\u003cbr\u003e Relative humidity: less than 95 % (non-condensing)\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tDimensions\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tHeight: 65 cm (26 in)\n\t\t\t\t\u003cbr\u003e Width: 39 cm (15 in)\u003cbr\u003e Depth: 75 cm (29 in)\u003cbr\u003e Weight: 50 kg (110 pounds)\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tElectrical Requirements\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t200-240V, 50\/60Hz\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\t\u003c\/table\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003ctable\u003e\n\t\u003ctbody\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd colspan=\"2\"\u003e\n\t\t\t\u003ccenter\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t\tComputer Specifications\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003c\/center\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\tProcessor\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\tIntel Core I5-8500 CPU\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\tRAM\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\t32.0 GB\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\tHard Drive\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\t500GB Internal SSD\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\tOperating System\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\tWindows 11 Professional, 64-bit\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\t\u003c\/table\u003e\n\t\u003cspan class=\"downloads-header\"\u003eDownloads\u003c\/span\u003e\n\t\u003cdiv class=\"downloads-section\"\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_6140A_Single_Quadrupole_Mass_Spectrometer_-_Marshall_Scientific.pdf?v=1779985740\" target=\"blank\"\u003e\n\t\t\tTechnical Specification Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_6100_Series_Single_Quadrupole_Mass_Spectrometers_Manual_-_Marshall_Scientific.pdf?v=1779985716\" target=\"blank\"\u003e\n\t\t\tOperator's Manual Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_6100_Series_Single_Quadrupole_Mass_Spectrometers_Site_Preparation_Guide_-_Marshall_Scientific.pdf?v=1779985720\" target=\"blank\"\u003e\n\t\t\tSite Prep Guide Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"formalquote2\"\u003e\n\t\t\u003ca class=\"formalquote2link\" href=\"\/formal_quote_a\/2847.htm\" target=\"blank\"\u003eRequest a Formal Quote\u003c\/a\u003e\n\t\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cspan class=\"windows11\"\u003e\u003c\/span\u003e","brand":"My Store","offers":[{"title":"Default Title","offer_id":42474493476954,"sku":"AG-6140AMS","price":50995.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-6140AMS-2.jpg?v=1761206477"},{"product_id":"agilent-6230a-accurate-mass-tof-mass-spectrometer","title":"Agilent 6230A Accurate-Mass TOF Mass Spectrometer","description":"\u003cdiv class=\"productdescriptiontables\"\u003e\n\t\u003ch1\u003eAgilent 6230A Accurate-Mass TOF Mass Spectrometer\u003c\/h1\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-section\"\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eMass Range\u003c\/b\u003e\u003cbr\u003em\/z 25 to 20,000\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eMass Accuracy\u003c\/b\u003e\u003cbr\u003e\u0026lt; 1 ppm (measured at m\/z 609.2807)\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eSpectral Acquisition Rate\u003c\/b\u003e\u003cbr\u003e30 spectra\/second (from m\/z 100 to 3,200)\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"features-section\"\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cspan class=\"features-header\"\u003eFeatures\u003c\/span\u003e\n\t\t\t\u003cul\u003e\n\t\t\t\t\u003cli\u003eOrthogonal acceleration TOF design for enhanced resolution and minimized entrance velocity effects\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eAgilent Jet Stream ESI technology for increased ionization efficiency and low picogram sensitivity\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eDynamic range spanning five orders of magnitude for detecting trace-level compounds in complex matrices\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eAutomated tuning and calibration for consistent performance and reduced user intervention\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eReal-time internal reference mass correction with built-in calibrant delivery system\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eResolving power of 22,000 FWHM for separating closely related compounds\u003c\/li\u003e\n\t\t\t\t\u003cli\u003ePolarity switching in under 1 second for versatile positive and negative ion analysis\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eSingle-point data control for seamless integration with HPLC systems and error management\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eOptional in-source dissociation for untargeted screening and enhanced fragmentation data\u003c\/li\u003e\n\t\t\t\u003c\/ul\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-6230.jpg?v=1779985757\"\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\n\tThe Agilent 6230A Accurate-Mass TOF Mass Spectrometer is a high-performance time-of-flight (TOF) system designed to provide precise, high-resolution mass measurements for a wide range of applications, including drug discovery, metabolomics, and environmental analysis. Utilizing orthogonal acceleration (oa-TOF) technology, this instrument directs ions perpendicularly to their original trajectory before they enter the flight tube, reducing entrance velocity effects and enhancing resolution. With its ability to capture a full mass spectrum scan up to 20,000 m\/z, the 6230A delivers superior analytical capabilities, allowing for accurate identification of unknown compounds, advanced statistical analysis, and in-depth biomolecule characterization. Equipped with Agilent Jet Stream (AJS) electrospray ionization (ESI) technology, the system enhances ion generation and transmission efficiency through a super-heated sheath gas, significantly increasing sensitivity while maintaining low detection limits. The 6230A ensures high-throughput sample screening with superior mass accuracy, reducing false positives with a precision of better than 1 ppm. This precision is maintained even in demanding workflows, supported by a high spectral acquisition rate of up to 30 spectra per second, enabling robust performance for fast ultra-high-performance liquid chromatography (UHPLC) separations.\n\t\u003cbr\u003e\u003cbr\u003e\n\tThe Agilent 6230A also offers advanced molecular profiling tools through the intuitive MassHunter software suite, featuring Find by Formula for compound identification based on accurate mass, isotopic abundance, and chemical composition. Additionally, the system supports high-resolution separation of complex mixtures, enabling confident elemental formula determination. With a broad dynamic range of up to five orders of magnitude, this TOF mass spectrometer can detect trace-level analytes even in complex matrices, making it a powerful tool for impurity profiling and advanced biological analysis. Designed for versatility, the 6230A supports multiple ionization sources, including ESI, atmospheric pressure chemical ionization (APCI), atmospheric pressure photoionization (APPI), multimode (ESI and APCI), HPLC-Chip\/MS interface, and AP\/MALDI PDF+ sources. It incorporates a dual-sprayer orthogonal ESI source with a built-in calibrant delivery system, allowing for real-time internal reference mass correction. The system's single-point data control integrates HPLC and TOF operations, automatically stopping sample injections if errors or leaks occur, improving workflow efficiency and reducing operational risks.\n\t\u003cbr\u003e\u003cbr\u003e\n\tWith a resolving power of 22,000 full width at half maximum (FWHM) and a mass accuracy stability of 2 ppm even with temperature fluctuations, the Agilent 6230A provides consistently high-quality data. The system’s automated tuning and calibration capabilities optimize ion optics and TOF-MS mass axis alignment, ensuring peak performance with minimal user intervention. For laboratories requiring untargeted screening, the system offers optional in-source dissociation for fragmentation data, further expanding its analytical capabilities. Built to streamline laboratory operations, the Agilent 6230A features MassHunter software, simplifying workflows and minimizing administrative tasks while enabling efficient, expert-level analysis without the need for extensive LC\/MS expertise. Whether analyzing monoclonal antibodies, glycoforms, truncations, or other biologic compounds, the Agilent 6230A provides unparalleled accuracy, resolution, and sensitivity, making it an essential instrument for laboratories seeking cutting-edge mass spectrometry performance.\n\t\u003cbr\u003e\u003cbr\u003e\u003cb\u003eThis Agilent MS system was recertified and calibrated by a factory trained engineer and is ready to ship on demand. This system comes with everything needed for easy installation and setup. All of our equipment is fully tested to perform at factory specifications before being shipped.\u003c\/b\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"included-box\"\u003e\n\t\t\u003cspan class=\"included-header\"\u003eINCLUDED:\u003c\/span\u003e\u003cbr\u003eThe Agilent 6230A Accurate-Mass TOF Mass Spectrometer includes:\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eAgilent 6230A Single Quadrupole Mass Spectrometer\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eAgilent MS40+ Rotary Vane Vacuum Pump\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eAgilent G1958B Jet Stream Electrospray Ionization Source\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eWindows 10 Professional 64-Bit Data Station with Flatscreen Monitor\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eAgilent MassHunter B.09.01 Acquisition and Data Analysis Software Installed\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eAgilent MassHunter BioConfirm Software Installed\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eAll Power Cords\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eCan\/Crossover Cables\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eLab Advisor Diagnostics Report \u0026amp; Mass Spec Tuning Report\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eFull 180 Day Parts and Labor Warranty\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003ch2\u003eAgilent 6230A Accurate-Mass TOF Mass Spectrometer Specifications\u003c\/h2\u003e\n\t\u003ctable\u003e\n\t\u003ctbody\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tMS Sensitivity with AJS (Included)\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tSignal-to-noise ratio \u0026gt; 50:1, Noise = 1 × RMS (1 pg reserpine injected on-column, measured at m\/z 609.2807)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tMS Sensitivity with ESI (Option 200)\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tSignal-to-noise ratio \u0026gt; 10:1, Noise = 1 × RMS (1 pg reserpine injected on-column, measured at m\/z 609.2807)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tMass Resolving Power\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t22,000 FWHM (measured at m\/z 1,522 after automatic tuning procedure)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tMass Accuracy - MS Mode\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u0026lt; 1 ppm (measured at m\/z 609.2807 using an internal reference mass)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tSpectral Acquisition Rate - MS Mode\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t30 spectra\/second (spectra acquisition from m\/z 100 to 3,200)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDynamic Range\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tUp to 5 decades (in-scan dynamic range on co-eluting components)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tMass Range\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tm\/z 25 to 20,000\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tPolarity Switching\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u0026lt; 1 sec (pos\/neg switching)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tMass Accuracy Temperature Stability - MS Mode\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tMaintain 2 ppm mass accuracy within 2°C drift per hour (temperature: 15°C to 35°C (59°F to 95°F) at constant temperature while setting autotune at 25°C)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tSingle Point of Control\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tSingle point data system method capability with full control for HPLC system and TOF, stopping sample injection if errors or leaks occur\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tIonization sources\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tElectrospray (ESI), Atmospheric pressure chemical ionization (APCI), Atmospheric pressure photoionization (APPI), Multimode source (ESI and APCI), HPLC-Chip\/MS interface, AP\/MALDI PDF+ source\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tTransparent Introduction of Reference Masses\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tDual-sprayer orthogonal ESI source, built-in calibrant delivery system, real-time internal reference mass correction for MS operation and heated sources\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tAutotune\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tAutomated optimization of ion optics and full TOF MS mass axis calibration\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tData Mining Tools\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tOne-button extraction of compound-specific spectral and chromatographic information using find compounds algorithms\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tMolecular Profiling Tools\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tMeasurement of molecular features from LC\/MS analyses (MassHunter), differential expression analysis with optional MassHunter Mass Profiler\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tSound Emission\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u0026lt; 70 db\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDimensions (L x W x H)\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t32.7 x 28.7 x 52.4 in. (83 x 73 x 133 cm)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tWeight\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t260 lb. (117.9 kg)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tElectrical Requirements\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t200-220VAC, 50\/60Hz, 15A\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\t\u003c\/table\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003ctable\u003e\n\t\u003ctbody\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd colspan=\"2\" width=\"623\"\u003e\n\t\t\t\u003cp style=\"text-align: center;\"\u003e\n\t\t\t\t\tComputer Specifications\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t\tModel\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t\tDell Optiplex 7010 Desktop PC\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t\tProcessor\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t\tIntel Core i5-6500 Processor 3.2GHz\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t\tRAM\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t\t16GB\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t\tHard Drive\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t\t250GB Internal SSD\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t\tOperating System\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t\tWindows 10 Professional, 64bit\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\t\u003c\/table\u003e\n\t\u003cspan class=\"downloads-header\"\u003eDownloads\u003c\/span\u003e\n\t\u003cdiv class=\"downloads-section\"\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_6230A_Accurate-Mass_TOF_Mass_Spectrometer_-_Marshall_Scientific.pdf?v=1779985761\" target=\"blank\"\u003e\n\t\t\tTechnical Specification Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_6230A_Accurate-Mass_TOF_Mass_Spectrometer_Manual_-_Marshall_Scientific.pdf?v=1779985766\" target=\"blank\"\u003e\n\t\t\tOperator's Manual Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_6200_Series_TOF_Mass_Spectrometers_Site_Preparation_Guide_-_Marshall_Scientific.pdf?v=1779985769\" target=\"blank\"\u003e\n\t\t\tSite Prep Guide Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"formalquote2\"\u003e\n\t\t\u003ca class=\"formalquote2link\" href=\"\/formal_quote_a\/2950.htm\" target=\"blank\"\u003eRequest a Formal Quote\u003c\/a\u003e\n\t\u003c\/div\u003e\n\u003c\/div\u003e","brand":"My Store","offers":[{"title":"Default Title","offer_id":42474494689370,"sku":"AG-6230AMS","price":62995.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-6230AMS-2T.jpg?v=1780433292"},{"product_id":"agilent-6230a-accurate-mass-tof-mass-spectrometer-w-1200-lc-system","title":"Agilent 6230A Accurate-Mass TOF Mass Spectrometer w\/ 1200 LC System","description":"\u003cdiv class=\"productdescriptiontables\"\u003e\n\u003ch1\u003eAgilent 6230A Accurate-Mass TOF Mass Spectrometer w\/ 1200 LC System\u003c\/h1\u003e\n\u003cbr\u003e\u003cbr\u003e\n\u003cdiv class=\"highlights-divider\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"highlights-section\"\u003e\n\u003cdiv class=\"inner-highlight-div\"\u003e\n\u003cp class=\"inner-highlight\"\u003e\u003cb\u003eMass Range\u003c\/b\u003e\u003cbr\u003em\/z 25 to 20,000\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"inner-highlight-div\"\u003e\n\u003cp class=\"inner-highlight\"\u003e\u003cb\u003eMass Accuracy\u003c\/b\u003e\u003cbr\u003e\u0026lt; 1 ppm (measured at m\/z 609.2807)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"inner-highlight-div\"\u003e\n\u003cp class=\"inner-highlight\"\u003e\u003cb\u003eSpectral Acquisition Rate\u003c\/b\u003e\u003cbr\u003e30 spectra\/second (from m\/z 100 to 3,200)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"highlights-divider\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"features-section\"\u003e\n\u003cdiv class=\"features-side\"\u003e\n\u003cspan class=\"features-header\"\u003eFeatures\u003c\/span\u003e\n\u003cul\u003e\n\u003cli\u003eOrthogonal acceleration TOF design for enhanced resolution and minimized entrance velocity effects\u003c\/li\u003e\n\u003cli\u003eAgilent Jet Stream ESI technology for increased ionization efficiency and low picogram sensitivity\u003c\/li\u003e\n\u003cli\u003eDynamic range spanning five orders of magnitude for detecting trace-level compounds in complex matrices\u003c\/li\u003e\n\u003cli\u003eAutomated tuning and calibration for consistent performance and reduced user intervention\u003c\/li\u003e\n\u003cli\u003eReal-time internal reference mass correction with built-in calibrant delivery system\u003c\/li\u003e\n\u003cli\u003eResolving power of 22,000 FWHM for separating closely related compounds\u003c\/li\u003e\n\u003cli\u003ePolarity switching in under 1 second for versatile positive and negative ion analysis\u003c\/li\u003e\n\u003cli\u003eSingle-point data control for seamless integration with HPLC systems and error management\u003c\/li\u003e\n\u003cli\u003eOptional in-source dissociation for untargeted screening and enhanced fragmentation data\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"features-side\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-6230.jpg?v=1779985757\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cbr\u003eThe Agilent 6230A Accurate-Mass TOF Mass Spectrometer w\/ 1200 LC System is a high-performance time-of-flight (TOF) system designed to provide precise, high-resolution mass measurements for a wide range of applications, including drug discovery, metabolomics, and environmental analysis. Utilizing orthogonal acceleration (oa-TOF) technology, this instrument directs ions perpendicularly to their original trajectory before they enter the flight tube, reducing entrance velocity effects and enhancing resolution. With its ability to capture a full mass spectrum scan up to 20,000 m\/z, the 6230A delivers superior analytical capabilities, allowing for accurate identification of unknown compounds, advanced statistical analysis, and in-depth biomolecule characterization. Equipped with Agilent Jet Stream (AJS) electrospray ionization (ESI) technology, the system enhances ion generation and transmission efficiency through a super-heated sheath gas, significantly increasing sensitivity while maintaining low detection limits. The 6230A ensures high-throughput sample screening with superior mass accuracy, reducing false positives with a precision of better than 1 ppm. This precision is maintained even in demanding workflows, supported by a high spectral acquisition rate of up to 30 spectra per second, enabling robust performance for fast ultra-high-performance liquid chromatography (UHPLC) separations. \u003cbr\u003e\u003cbr\u003eThe Agilent 6230A also offers advanced molecular profiling tools through the intuitive MassHunter software suite, featuring Find by Formula for compound identification based on accurate mass, isotopic abundance, and chemical composition. Additionally, the system supports high-resolution separation of complex mixtures, enabling confident elemental formula determination. With a broad dynamic range of up to five orders of magnitude, this TOF mass spectrometer can detect trace-level analytes even in complex matrices, making it a powerful tool for impurity profiling and advanced biological analysis. Designed for versatility, the 6230A supports multiple ionization sources, including ESI, atmospheric pressure chemical ionization (APCI), atmospheric pressure photoionization (APPI), multimode (ESI and APCI), HPLC-Chip\/MS interface, and AP\/MALDI PDF+ sources. It incorporates a dual-sprayer orthogonal ESI source with a built-in calibrant delivery system, allowing for real-time internal reference mass correction. The system's single-point data control integrates HPLC and TOF operations, automatically stopping sample injections if errors or leaks occur, improving workflow efficiency and reducing operational risks. \u003cbr\u003e\u003cbr\u003eWith a resolving power of 22,000 full width at half maximum (FWHM) and a mass accuracy stability of 2 ppm even with temperature fluctuations, the Agilent 6230A provides consistently high-quality data. The system’s automated tuning and calibration capabilities optimize ion optics and TOF-MS mass axis alignment, ensuring peak performance with minimal user intervention. For laboratories requiring untargeted screening, the system offers optional in-source dissociation for fragmentation data, further expanding its analytical capabilities. Built to streamline laboratory operations, the Agilent 6230A features MassHunter software, simplifying workflows and minimizing administrative tasks while enabling efficient, expert-level analysis without the need for extensive LC\/MS expertise. Whether analyzing monoclonal antibodies, glycoforms, truncations, or other biologic compounds, the Agilent 6230A provides unparalleled accuracy, resolution, and sensitivity, making it an essential instrument for laboratories seeking cutting-edge mass spectrometry performance. \u003cbr\u003e\u003cbr\u003e\u003cb\u003eThis Agilent LC\/MS system was recertified and calibrated by a factory trained engineer and is ready to ship on demand. This system comes with everything needed for easy installation and setup. All of our equipment is fully tested to perform at factory specifications before being shipped.\u003c\/b\u003e \u003cbr\u003e\u003cbr\u003e\n\u003cdiv class=\"included-box\"\u003e\n\u003cspan class=\"included-header\"\u003eINCLUDED:\u003c\/span\u003e\u003cbr\u003eThe Agilent 6230A Accurate-Mass TOF Mass Spectrometer w\/ 1200 LC System includes:\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eAgilent 6230A Single Quadrupole Mass Spectrometer\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eAgilent MS40+ Rotary Vane Vacuum Pump\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eAgilent G1958B Jet Stream Electrospray Ionization Source\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eG1312B Binary Pump (G1311A Quaternary Pump available, please inquire)\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eG1329A Autosampler\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eG1330B ALS Thermostat\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eG1316A TCC\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eG1379B Degasser\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eG1315C DAD Detector\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eWindows 10 Professional 64-Bit Data Station with Flatscreen Monitor\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eAgilent MassHunter B.09.01 Acquisition and Data Analysis Software Installed\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eAgilent MassHunter BioConfirm Software Installed\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eAll Power Cords\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eCan\/Crossover Cables\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eAgilent Lan Interface Card Built-In\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eSolvent Tubing\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eCapillaries\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eAgilent 4 Peak Test w\/ Lab Advisor Diagnostics Report \u0026amp; Mass Spec Tuning Report\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eFull 180 Day Parts and Labor Warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\n\u003cdiv class=\"agilent-tests\"\u003e\n\u003cspan class=\"agilent-tests-title\"\u003eBelow is a List of Diagnostic Tests Performed On This LC System\u003c\/span\u003e\u003cbr\u003e\u003cspan class=\"agilent-tests-header\"\u003eG1315C Diode Array Detector Diagnostic Tests:\u003c\/span\u003e\n\u003cul\u003e\n\u003cli\u003eFilter Test: The test moves the filter into the light path and measures the relative absorbance in the filter position.\u003c\/li\u003e\n\u003cli\u003eDark Current Test: The test measures the dark current from the detector optic.\u003c\/li\u003e\n\u003cli\u003eHolmium Oxide Test: The test measures the Holmium spectrum from the built-in Holmium filter. The spectrum is evaluated for peaks at different wavelengths.\u003c\/li\u003e\n\u003cli\u003eLamp Intensity Test: The test verifies functionality of the UV lamp at various wavelengths.\u003c\/li\u003e\n\u003cli\u003eWavelength Intensity Test: The test confirms the accuracy of wavelengths measured.\u003c\/li\u003e\n\u003cli\u003eBaseline Noise Test: The test measures the amount of baseline noise drift identified by the detector.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cspan class=\"agilent-tests-header\"\u003eG1312B Binary Pump Diagnostic Tests:\u003c\/span\u003e\n\u003cul\u003e\n\u003cli\u003ePressure Test: The pressure test is a quick, built-in test designed to demonstrate the pressure tightness (up to 400 bar) of the system.\u003c\/li\u003e\n\u003cli\u003eLeak Test: The leak test is a built-in troubleshooting designed to demonstrate the leak-tightness of the pump.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cspan class=\"agilent-tests-header\"\u003eG1316A Column Compartment Diagnostic Tests:\u003c\/span\u003e\n\u003cul\u003e\n\u003cli\u003eThermostat Test: Evaluates the cooling and heating performance of the two Peltier elements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cspan class=\"agilent-tests-header\"\u003eG1329A Autosampler Diagnostic Tests:\u003c\/span\u003e\n\u003cul\u003e\n\u003cli\u003eInjector Steps: Performs each movement of the sampling sequence under manual control. This is useful for confirming autosampler functionality.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cspan class=\"agilent-tests-header\"\u003eSystem Tests:\u003c\/span\u003e\n\u003cul\u003e\n\u003cli\u003e4 Peak Test (Isocratic Standard): Standard test published by Agilent to confirm complete functionality of the 1200 LC System.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\u003cbr\u003e\n\u003ch2\u003eAgilent 6230A Accurate-Mass TOF Mass Spectrometer Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMS Sensitivity with AJS (Included)\u003c\/td\u003e\n\u003ctd\u003eSignal-to-noise ratio \u0026gt; 50:1, Noise = 1 × RMS (1 pg reserpine injected on-column, measured at m\/z 609.2807)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMS Sensitivity with ESI (Option 200)\u003c\/td\u003e\n\u003ctd\u003eSignal-to-noise ratio \u0026gt; 10:1, Noise = 1 × RMS (1 pg reserpine injected on-column, measured at m\/z 609.2807)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMass Resolving Power\u003c\/td\u003e\n\u003ctd\u003e22,000 FWHM (measured at m\/z 1,522 after automatic tuning procedure)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMass Accuracy - MS Mode\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 1 ppm (measured at m\/z 609.2807 using an internal reference mass)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpectral Acquisition Rate - MS Mode\u003c\/td\u003e\n\u003ctd\u003e30 spectra\/second (spectra acquisition from m\/z 100 to 3,200)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDynamic Range\u003c\/td\u003e\n\u003ctd\u003eUp to 5 decades (in-scan dynamic range on co-eluting components)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMass Range\u003c\/td\u003e\n\u003ctd\u003em\/z 25 to 20,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePolarity Switching\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 1 sec (pos\/neg switching)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMass Accuracy Temperature Stability - MS Mode\u003c\/td\u003e\n\u003ctd\u003eMaintain 2 ppm mass accuracy within 2°C drift per hour (temperature: 15°C to 35°C (59°F to 95°F) at constant temperature while setting autotune at 25°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle Point of Control\u003c\/td\u003e\n\u003ctd\u003eSingle point data system method capability with full control for HPLC system and TOF, stopping sample injection if errors or leaks occur\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIonization sources\u003c\/td\u003e\n\u003ctd\u003eElectrospray (ESI), Atmospheric pressure chemical ionization (APCI), Atmospheric pressure photoionization (APPI), Multimode source (ESI and APCI), HPLC-Chip\/MS interface, AP\/MALDI PDF+ source\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransparent Introduction of Reference Masses\u003c\/td\u003e\n\u003ctd\u003eDual-sprayer orthogonal ESI source, built-in calibrant delivery system, real-time internal reference mass correction for MS operation and heated sources\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutotune\u003c\/td\u003e\n\u003ctd\u003eAutomated optimization of ion optics and full TOF MS mass axis calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Mining Tools\u003c\/td\u003e\n\u003ctd\u003eOne-button extraction of compound-specific spectral and chromatographic information using find compounds algorithms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMolecular Profiling Tools\u003c\/td\u003e\n\u003ctd\u003eMeasurement of molecular features from LC\/MS analyses (MassHunter), differential expression analysis with optional MassHunter Mass Profiler\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound Emission\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 70 db\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (L x W x H)\u003c\/td\u003e\n\u003ctd\u003e32.7 x 28.7 x 52.4 in. (83 x 73 x 133 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e260 lb. (117.9 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Requirements\u003c\/td\u003e\n\u003ctd\u003e200-220VAC, 50\/60Hz, 15A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003cdiv class=\"show-hidden-table\"\u003eClick Here to View Specifications for the Agilent 1200 LC System\u003c\/div\u003e\n\u003cbr\u003e\n\u003cdiv class=\"hidden-table\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDAD Detector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection Type\u003c\/td\u003e\n\u003ctd\u003e1024-element photodiode array\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Source\u003c\/td\u003e\n\u003ctd\u003eDeuterium and tungsten lamps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength Range\u003c\/td\u003e\n\u003ctd\u003e190 - 950 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort Term Noise (ASTM) Single and Multi-Wavelength\u003c\/td\u003e\n\u003ctd\u003e± 0.8 × 10 \u003csup\u003e-5\u003c\/sup\u003e AU at 254 and 750 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrift\u003c\/td\u003e\n\u003ctd\u003e0.9 × 10 \u003csup\u003e-3\u003c\/sup\u003e AU\/hr at 254 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinear Absorbance Range\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 2.0 AU (upper limit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength Accuracy\u003c\/td\u003e\n\u003ctd\u003e± 1 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength Bunching\u003c\/td\u003e\n\u003ctd\u003e1 - 400 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlit Width\u003c\/td\u003e\n\u003ctd\u003e1, 2, 4, 8, 16 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiode Width\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 1 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow Cells\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eStandard: 13 µL volume, 10 mm cell path length and 120 bar (1740 psi) pressure maximum\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBinary Pump\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHydraulic System\u003c\/td\u003e\n\u003ctd\u003eTwo dual piston in series pumps with proprietary servo-controlled variable stroke drive, floating piston design and active inlet valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSetable Flow Range\u003c\/td\u003e\n\u003ctd\u003e0.001 – 5 ml\/min, in 0.001 ml\/min increments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow Range\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0.1 - 5.0 mL\/min\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow Precision\u003c\/td\u003e\n\u003ctd\u003e≤ 0.07% RSD or ≤ 0.02 min SD, whatever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow Accuracy\u003c\/td\u003e\n\u003ctd\u003e± 1% or 10 µl\/min, what ever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure Operating Range\u003c\/td\u003e\n\u003ctd\u003eOperating range 0 to 600 bar (0 – 7800 psi) up to 5 ml\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure Pulsation\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 2 % amplitude (typically \u0026lt; 1 %), at 1 ml\/min isopropanol, at all pressures \u0026gt; 1 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressibility Compensation\u003c\/td\u003e\n\u003ctd\u003eUser-selectable, based on mobile phase compressibility\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended pH Range\u003c\/td\u003e\n\u003ctd\u003e1.0 - 12.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGradient Formation\u003c\/td\u003e\n\u003ctd\u003eHigh-pressure binary mixing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDelay Volume\u003c\/td\u003e\n\u003ctd\u003e600 to 800 µl, dependent on back pressure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eComposition Range\u003c\/td\u003e\n\u003ctd\u003e0 to 100% (1 to 99% or 5 µl\/min per channel, whatever is greater is recommended)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eComposition Precision\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.15% RSD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eComposition Accuracy\u003c\/td\u003e\n\u003ctd\u003e± 0.35% absolute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAutosampler\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInjection Range\u003c\/td\u003e\n\u003ctd\u003e0.1 - 100 µl in 0.1 µl increments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrecision\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u0026lt; 0.25 % RSD of peak areas from 5 to 100 µl\u003c\/p\u003e\n\u003cp\u003e\u0026lt; 1 % RSD of peak areas from 1 to 5 µl\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure Range\u003c\/td\u003e\n\u003ctd\u003eOperating range 0 - 60 MPa (0 - 600 bar, 0 - 8850 psi)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample Viscosity Range\u003c\/td\u003e\n\u003ctd\u003e0.2 to 50 cp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample Capacity\u003c\/td\u003e\n\u003ctd\u003e100 × 2 mL vials in 1 tray \u003cbr\u003e40 × 2 mL vials in ½ tray\u003cbr\u003e15 × 6 mL vials in ½ tray (Agilent vials only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInjection Cycle Time\u003c\/td\u003e\n\u003ctd\u003e50 s for draw speed 200 µL\/min, ejection speed 200 µL\/min, injection volume 5 µL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarryover\u003c\/td\u003e\n\u003ctd\u003eTypically \u0026lt; 0.1 %, \u0026lt; 0.05 % with external needle cleaning\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eALS Thermostat\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e4°C to 40°C in 1°C increments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy at Ambient Temperatures \u0026lt; 25°C and Humidity \u0026lt; 50%\u003c\/td\u003e\n\u003ctd\u003e-1°C to +4°C at a setpoint of 4°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy at Ambient Temperatures \u0026gt; 25°C and Humidity \u0026gt; 50%\u003c\/td\u003e\n\u003ctd\u003e-1°C to +5°C at a setpoint of 4°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eColumn Compartment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003eAmbient -10°C to 80°C at flow rates up to 5 mL\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Stability\u003c\/td\u003e\n\u003ctd\u003e± 0.15 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e± 0.8°C (± 0.5°C with calibration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColumn Capacity\u003c\/td\u003e\n\u003ctd\u003eThree 30 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarm-Up\/Cool-Down Time\u003c\/td\u003e\n\u003ctd\u003e5 minutes from ambient to 40°C \u003cbr\u003e10 minutes from 40°C to 20°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDead Volume\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e3 µl left heat exchanger\u003c\/p\u003e\n\u003cp\u003e6 µl right heat exchanger\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDegasser\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Solvent Channels\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Flow Rate\u003c\/td\u003e\n\u003ctd\u003e0 - 10 mL\/min per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Volume Per Channel\u003c\/td\u003e\n\u003ctd\u003eTypically 12 ml per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaterials in Contact with Solvent\u003c\/td\u003e\n\u003ctd\u003ePTFE, PEEK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e1 - 14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\u003cbr\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" width=\"623\"\u003e\n\u003cp style=\"text-align: center;\"\u003eComputer Specifications\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eModel\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eDell Optiplex 7010 Desktop PC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eProcessor\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIntel Core i5-6500 Processor 3.2GHz\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRAM\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e16GB\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eHard Drive\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e250GB Internal SSD\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOperating System\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eWindows 10 Professional, 64bit\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cspan class=\"downloads-header\"\u003eDownloads\u003c\/span\u003e\n\u003cdiv class=\"downloads-section\"\u003e\n\u003cdiv class=\"pdf-button\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_6230A_Accurate-Mass_TOF_Mass_Spectrometer_-_Marshall_Scientific.pdf?v=1779985761\"\u003e Technical Specification Download \u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"pdf-button\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_6230A_Accurate-Mass_TOF_Mass_Spectrometer_Manual_-_Marshall_Scientific.pdf?v=1779985766\"\u003e Operator's Manual Download \u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"pdf-button\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_6200_Series_TOF_Mass_Spectrometers_Site_Preparation_Guide_-_Marshall_Scientific.pdf?v=1779985769\"\u003e Site Prep Guide Download \u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"formalquote2\"\u003e\u003ca class=\"formalquote2link\" href=\"\/formal_quote_a\/2951.htm\"\u003eRequest a Formal Quote\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"My Store","offers":[{"title":"Default Title","offer_id":42474494754906,"sku":"AG-6230AMS1200","price":85495.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-6230AMS1200-2T.jpg?v=1780433160"},{"product_id":"agilent-6230a-accurate-mass-tof-mass-spectrometer-w-1260-infinity-i-lc-system","title":"Agilent 6230A Accurate-Mass TOF Mass Spectrometer w\/ 1260 Infinity I LC System","description":"\u003cdiv class=\"productdescriptiontables\"\u003e\n\u003ch1\u003eAgilent 6230A Accurate-Mass TOF Mass Spectrometer w\/ 1260 Infinity I LC System\u003c\/h1\u003e\n\u003cbr\u003e\u003cbr\u003e\n\u003cdiv class=\"highlights-divider\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"highlights-section\"\u003e\n\u003cdiv class=\"inner-highlight-div\"\u003e\n\u003cp class=\"inner-highlight\"\u003e\u003cb\u003eMass Range\u003c\/b\u003e\u003cbr\u003em\/z 25 to 20,000\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"inner-highlight-div\"\u003e\n\u003cp class=\"inner-highlight\"\u003e\u003cb\u003eMass Accuracy\u003c\/b\u003e\u003cbr\u003e\u0026lt; 1 ppm (measured at m\/z 609.2807)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"inner-highlight-div\"\u003e\n\u003cp class=\"inner-highlight\"\u003e\u003cb\u003eSpectral Acquisition Rate\u003c\/b\u003e\u003cbr\u003e30 spectra\/second (from m\/z 100 to 3,200)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"highlights-divider\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"features-section\"\u003e\n\u003cdiv class=\"features-side\"\u003e\n\u003cspan class=\"features-header\"\u003eFeatures\u003c\/span\u003e\n\u003cul\u003e\n\u003cli\u003eOrthogonal acceleration TOF design for enhanced resolution and minimized entrance velocity effects\u003c\/li\u003e\n\u003cli\u003eAgilent Jet Stream ESI technology for increased ionization efficiency and low picogram sensitivity\u003c\/li\u003e\n\u003cli\u003eDynamic range spanning five orders of magnitude for detecting trace-level compounds in complex matrices\u003c\/li\u003e\n\u003cli\u003eAutomated tuning and calibration for consistent performance and reduced user intervention\u003c\/li\u003e\n\u003cli\u003eReal-time internal reference mass correction with built-in calibrant delivery system\u003c\/li\u003e\n\u003cli\u003eResolving power of 22,000 FWHM for separating closely related compounds\u003c\/li\u003e\n\u003cli\u003ePolarity switching in under 1 second for versatile positive and negative ion analysis\u003c\/li\u003e\n\u003cli\u003eSingle-point data control for seamless integration with HPLC systems and error management\u003c\/li\u003e\n\u003cli\u003eOptional in-source dissociation for untargeted screening and enhanced fragmentation data\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"features-side\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-6230.jpg?v=1779985757\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cbr\u003eThe Agilent 6230A Accurate-Mass TOF Mass Spectrometer w\/ 1260 Infinity I LC System is a high-performance time-of-flight (TOF) system designed to provide precise, high-resolution mass measurements for a wide range of applications, including drug discovery, metabolomics, and environmental analysis. Utilizing orthogonal acceleration (oa-TOF) technology, this instrument directs ions perpendicularly to their original trajectory before they enter the flight tube, reducing entrance velocity effects and enhancing resolution. With its ability to capture a full mass spectrum scan up to 20,000 m\/z, the 6230A delivers superior analytical capabilities, allowing for accurate identification of unknown compounds, advanced statistical analysis, and in-depth biomolecule characterization. Equipped with Agilent Jet Stream (AJS) electrospray ionization (ESI) technology, the system enhances ion generation and transmission efficiency through a super-heated sheath gas, significantly increasing sensitivity while maintaining low detection limits. The 6230A ensures high-throughput sample screening with superior mass accuracy, reducing false positives with a precision of better than 1 ppm. This precision is maintained even in demanding workflows, supported by a high spectral acquisition rate of up to 30 spectra per second, enabling robust performance for fast ultra-high-performance liquid chromatography (UHPLC) separations. \u003cbr\u003e\u003cbr\u003eThe Agilent 6230A also offers advanced molecular profiling tools through the intuitive MassHunter software suite, featuring Find by Formula for compound identification based on accurate mass, isotopic abundance, and chemical composition. Additionally, the system supports high-resolution separation of complex mixtures, enabling confident elemental formula determination. With a broad dynamic range of up to five orders of magnitude, this TOF mass spectrometer can detect trace-level analytes even in complex matrices, making it a powerful tool for impurity profiling and advanced biological analysis. Designed for versatility, the 6230A supports multiple ionization sources, including ESI, atmospheric pressure chemical ionization (APCI), atmospheric pressure photoionization (APPI), multimode (ESI and APCI), HPLC-Chip\/MS interface, and AP\/MALDI PDF+ sources. It incorporates a dual-sprayer orthogonal ESI source with a built-in calibrant delivery system, allowing for real-time internal reference mass correction. The system's single-point data control integrates HPLC and TOF operations, automatically stopping sample injections if errors or leaks occur, improving workflow efficiency and reducing operational risks. \u003cbr\u003e\u003cbr\u003eWith a resolving power of 22,000 full width at half maximum (FWHM) and a mass accuracy stability of 2 ppm even with temperature fluctuations, the Agilent 6230A provides consistently high-quality data. The system’s automated tuning and calibration capabilities optimize ion optics and TOF-MS mass axis alignment, ensuring peak performance with minimal user intervention. For laboratories requiring untargeted screening, the system offers optional in-source dissociation for fragmentation data, further expanding its analytical capabilities. Built to streamline laboratory operations, the Agilent 6230A features MassHunter software, simplifying workflows and minimizing administrative tasks while enabling efficient, expert-level analysis without the need for extensive LC\/MS expertise. Whether analyzing monoclonal antibodies, glycoforms, truncations, or other biologic compounds, the Agilent 6230A provides unparalleled accuracy, resolution, and sensitivity, making it an essential instrument for laboratories seeking cutting-edge mass spectrometry performance. \u003cbr\u003e\u003cbr\u003e\u003cb\u003eThis Agilent LC\/MS system was recertified and calibrated by a factory trained engineer and is ready to ship on demand. This system comes with everything needed for easy installation and setup. All of our equipment is fully tested to perform at factory specifications before being shipped.\u003c\/b\u003e \u003cbr\u003e\u003cbr\u003e\n\u003cdiv class=\"included-box\"\u003e\n\u003cspan class=\"included-header\"\u003eINCLUDED:\u003c\/span\u003e\u003cbr\u003eThe Agilent 6230A Accurate-Mass TOF Mass Spectrometer w\/ 1260 Infinity I LC System includes:\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eAgilent 6230A Single Quadrupole Mass Spectrometer\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eAgilent MS40+ Rotary Vane Vacuum Pump\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eAgilent G1958B Jet Stream Electrospray Ionization Source\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eG1312B Binary Pump (G1311B Quaternary Pump available, please inquire)\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eG1329B Autosampler\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eG1330B ALS Thermostat\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eG1316A TCC\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eG1379B Degasser\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eG4212B DAD Detector\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eWindows 10 Professional 64-Bit Data Station with Flatscreen Monitor\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eAgilent MassHunter B.09.01 Acquisition and Data Analysis Software Installed\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eAgilent MassHunter BioConfirm Software Installed\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eAll Power Cords\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eCan\/Crossover Cables\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eAgilent Lan Interface Card Built-In\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eSolvent Tubing\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eCapillaries\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eAgilent 4 Peak Test w\/ Lab Advisor Diagnostics Report \u0026amp; Mass Spec Tuning Report\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eFull 180 Day Parts and Labor Warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\n\u003cdiv class=\"agilent-tests\"\u003e\n\u003cspan class=\"agilent-tests-title\"\u003eBelow is a List of Diagnostic Tests Performed On This LC System\u003c\/span\u003e\u003cbr\u003e\u003cspan class=\"agilent-tests-header\"\u003eG4212B Diode Array Detector Diagnostic Tests:\u003c\/span\u003e\n\u003cul\u003e\n\u003cli\u003eFilter Test: The test moves the filter into the light path and measures the relative absorbance in the filter position.\u003c\/li\u003e\n\u003cli\u003eDark Current Test: The test measures the dark current from the detector optic.\u003c\/li\u003e\n\u003cli\u003eHolmium Oxide Test: The test measures the Holmium spectrum from the built-in Holmium filter. The spectrum is evaluated for peaks at different wavelengths.\u003c\/li\u003e\n\u003cli\u003eLamp Intensity Test: The test verifies functionality of the UV lamp at various wavelengths.\u003c\/li\u003e\n\u003cli\u003eWavelength Intensity Test: The test confirms the accuracy of wavelengths measured.\u003c\/li\u003e\n\u003cli\u003eBaseline Noise Test: The test measures the amount of baseline noise drift identified by the detector.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cspan class=\"agilent-tests-header\"\u003eG1312B Binary Pump Diagnostic Tests:\u003c\/span\u003e\n\u003cul\u003e\n\u003cli\u003ePressure Test: The pressure test is a quick, built-in test designed to demonstrate the pressure tightness (up to 400 bar) of the system.\u003c\/li\u003e\n\u003cli\u003eLeak Test: The leak test is a built-in troubleshooting designed to demonstrate the leak-tightness of the pump.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cspan class=\"agilent-tests-header\"\u003eG1316A Column Compartment Diagnostic Tests:\u003c\/span\u003e\n\u003cul\u003e\n\u003cli\u003eThermostat Test: Evaluates the cooling and heating performance of the two Peltier elements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cspan class=\"agilent-tests-header\"\u003eG1329B Autosampler Diagnostic Tests:\u003c\/span\u003e\n\u003cul\u003e\n\u003cli\u003eInjector Steps: Performs each movement of the sampling sequence under manual control. This is useful for confirming autosampler functionality.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cspan class=\"agilent-tests-header\"\u003eSystem Tests:\u003c\/span\u003e\n\u003cul\u003e\n\u003cli\u003e4 Peak Test (Isocratic Standard): Standard test published by Agilent to confirm complete functionality of the 1260 Infinity I LC System.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\u003cbr\u003e\n\u003ch2\u003eAgilent 6230A Accurate-Mass TOF Mass Spectrometer Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMS Sensitivity with AJS (Included)\u003c\/td\u003e\n\u003ctd\u003eSignal-to-noise ratio \u0026gt; 50:1, Noise = 1 × RMS (1 pg reserpine injected on-column, measured at m\/z 609.2807)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMS Sensitivity with ESI (Option 200)\u003c\/td\u003e\n\u003ctd\u003eSignal-to-noise ratio \u0026gt; 10:1, Noise = 1 × RMS (1 pg reserpine injected on-column, measured at m\/z 609.2807)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMass Resolving Power\u003c\/td\u003e\n\u003ctd\u003e22,000 FWHM (measured at m\/z 1,522 after automatic tuning procedure)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMass Accuracy - MS Mode\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 1 ppm (measured at m\/z 609.2807 using an internal reference mass)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpectral Acquisition Rate - MS Mode\u003c\/td\u003e\n\u003ctd\u003e30 spectra\/second (spectra acquisition from m\/z 100 to 3,200)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDynamic Range\u003c\/td\u003e\n\u003ctd\u003eUp to 5 decades (in-scan dynamic range on co-eluting components)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMass Range\u003c\/td\u003e\n\u003ctd\u003em\/z 25 to 20,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePolarity Switching\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 1 sec (pos\/neg switching)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMass Accuracy Temperature Stability - MS Mode\u003c\/td\u003e\n\u003ctd\u003eMaintain 2 ppm mass accuracy within 2°C drift per hour (temperature: 15°C to 35°C (59°F to 95°F) at constant temperature while setting autotune at 25°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle Point of Control\u003c\/td\u003e\n\u003ctd\u003eSingle point data system method capability with full control for HPLC system and TOF, stopping sample injection if errors or leaks occur\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIonization sources\u003c\/td\u003e\n\u003ctd\u003eElectrospray (ESI), Atmospheric pressure chemical ionization (APCI), Atmospheric pressure photoionization (APPI), Multimode source (ESI and APCI), HPLC-Chip\/MS interface, AP\/MALDI PDF+ source\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransparent Introduction of Reference Masses\u003c\/td\u003e\n\u003ctd\u003eDual-sprayer orthogonal ESI source, built-in calibrant delivery system, real-time internal reference mass correction for MS operation and heated sources\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutotune\u003c\/td\u003e\n\u003ctd\u003eAutomated optimization of ion optics and full TOF MS mass axis calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Mining Tools\u003c\/td\u003e\n\u003ctd\u003eOne-button extraction of compound-specific spectral and chromatographic information using find compounds algorithms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMolecular Profiling Tools\u003c\/td\u003e\n\u003ctd\u003eMeasurement of molecular features from LC\/MS analyses (MassHunter), differential expression analysis with optional MassHunter Mass Profiler\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound Emission\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 70 db\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (L x W x H)\u003c\/td\u003e\n\u003ctd\u003e32.7 x 28.7 x 52.4 in. (83 x 73 x 133 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e260 lb. (117.9 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Requirements\u003c\/td\u003e\n\u003ctd\u003e200-220VAC, 50\/60Hz, 15A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003cdiv class=\"show-hidden-table\"\u003eClick Here to View Specifications for the Agilent 1260 Infinity I LC System\u003c\/div\u003e\n\u003cbr\u003e\n\u003cdiv class=\"hidden-table\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDAD Detector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection Type\u003c\/td\u003e\n\u003ctd\u003e1024-element photodiode array\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Source\u003c\/td\u003e\n\u003ctd\u003eDeuterium and tungsten lamps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength Range\u003c\/td\u003e\n\u003ctd\u003e190 - 640 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort Term Noise (ASTM) Single and Multi-Wavelength\u003c\/td\u003e\n\u003ctd\u003e± 3 × 10 \u003csup\u003e-6\u003c\/sup\u003e AU at 230 nm\/4 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrift\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.5 × 10 \u003csup\u003e-3\u003c\/sup\u003e AU\/hr at 230 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinear Absorbance Range\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 2.0 AU (5%) at 265 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength Accuracy\u003c\/td\u003e\n\u003ctd\u003e± 1 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength Bunching\u003c\/td\u003e\n\u003ctd\u003e1 - 400 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlit Width\u003c\/td\u003e\n\u003ctd\u003e4 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiode Width\u003c\/td\u003e\n\u003ctd\u003e~ 0.5 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow Cell\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eStandard: 13 µL volume, 10 mm cell path length and 120 bar (1740 psi) pressure maximum\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBinary Pump\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHydraulic System\u003c\/td\u003e\n\u003ctd\u003eTwo dual piston in series pumps with proprietary servo-controlled variable stroke drive, power transmission by gears and ball screws, floating pistons\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSetable Flow Range\u003c\/td\u003e\n\u003ctd\u003e0.001 – 5 ml\/min, in 0.001 ml\/min increments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow Range\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0.5 - 5.0 mL\/min\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow Precision\u003c\/td\u003e\n\u003ctd\u003e≤ 0.07% RSD or ≤ 0.02 min SD, whatever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow Accuracy\u003c\/td\u003e\n\u003ctd\u003e± 1% or 10 µl\/min, what ever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure Operating Range\u003c\/td\u003e\n\u003ctd\u003eOperating range 0 to 600 bar (0 – 7800 psi) up to 5 ml\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure Pulsation\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 2 % amplitude (typically \u0026lt; 1.3 %), or \u0026lt; 0.3 MPa (3 bar), whatever is greater, at 1 mL\/min isopropanol, at all pressures \u0026gt; 1 MPa (10 bar, 147 psi)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressibility Compensation\u003c\/td\u003e\n\u003ctd\u003eUser-selectable, based on mobile phase compressibility\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended pH Range\u003c\/td\u003e\n\u003ctd\u003e1.0 - 12.5, solvents with pH \u0026lt; 2.3 should not contain acids which attack stainless stee\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGradient Formation\u003c\/td\u003e\n\u003ctd\u003eHigh-pressure binary mixing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDelay Volume\u003c\/td\u003e\n\u003ctd\u003e600 to 800 µl, dependent on back pressure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eComposition Range\u003c\/td\u003e\n\u003ctd\u003e0 to 100% (1 to 99% or 5 µl\/min per channel, whatever is greater is recommended)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eComposition Precision\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.15% RSD or \u0026lt; 0.04 min SD whatever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eComposition Accuracy\u003c\/td\u003e\n\u003ctd\u003e± 0.35% absolute at 2 mL\/min, at 10 MPa (100 bar)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAutosampler\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInjection Range\u003c\/td\u003e\n\u003ctd\u003e0.1 - 100 µl in 0.1 µl increments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrecision\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u0026lt; 0.25 % RSD of peak areas from 5 to 100 µl\u003c\/p\u003e\n\u003cp\u003e\u0026lt; 1 % RSD of peak areas from 1 to 5 µl\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure Range\u003c\/td\u003e\n\u003ctd\u003eOperating range 0 - 60 MPa (0 - 600 bar, 0 - 8850 psi)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample Viscosity Range\u003c\/td\u003e\n\u003ctd\u003e0.2 to 50 cp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample Capacity\u003c\/td\u003e\n\u003ctd\u003e100 × 2 mL vials in 1 tray \u003cbr\u003e40 × 2 mL vials in ½ tray\u003cbr\u003e15 × 6 mL vials in ½ tray (Agilent vials only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInjection Cycle Time\u003c\/td\u003e\n\u003ctd\u003e50 s for draw speed 200 µL\/min, ejection speed 200 µL\/min, injection volume 5 µL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarryover\u003c\/td\u003e\n\u003ctd\u003eTypically \u0026lt; 0.1 %, \u0026lt; 0.05 % with external needle cleaning\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eALS Thermostat\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e4°C to 40°C in 1°C increments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy at Ambient Temperatures \u0026lt; 25°C and Humidity \u0026lt; 50%\u003c\/td\u003e\n\u003ctd\u003e3°C to +8°C at a setpoint of 4°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy at Ambient Temperatures \u0026gt; 30°C and Humidity \u0026gt; 60%\u003c\/td\u003e\n\u003ctd\u003e3°C to +9°C at a setpoint of 4°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eColumn Compartment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003eAmbient -10°C to 80°C at flow rates up to 5 mL\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Stability\u003c\/td\u003e\n\u003ctd\u003e± 0.15 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e± 0.8°C (± 0.5°C with calibration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColumn Capacity\u003c\/td\u003e\n\u003ctd\u003eThree 30 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarm-Up\/Cool-Down Time\u003c\/td\u003e\n\u003ctd\u003e5 minutes from ambient to 40°C \u003cbr\u003e10 minutes from 40°C to 20°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDead Volume\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e3 µl left heat exchanger\u003c\/p\u003e\n\u003cp\u003e6 µl right heat exchanger\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDegasser\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Solvent Channels\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Flow Rate\u003c\/td\u003e\n\u003ctd\u003e0 - 5 mL\/min per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Volume Per Channel\u003c\/td\u003e\n\u003ctd\u003eTypically 1 ml per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaterials in Contact with Solvent\u003c\/td\u003e\n\u003ctd\u003ePTFE, PEEK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e1 - 14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\u003cbr\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" width=\"623\"\u003e\n\u003cp style=\"text-align: center;\"\u003eComputer Specifications\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eModel\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eDell Optiplex 7010 Desktop PC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eProcessor\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIntel Core i5-6500 Processor 3.2GHz\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRAM\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e16GB\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eHard Drive\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e250GB Internal SSD\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOperating System\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eWindows 10 Professional, 64bit\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cspan class=\"downloads-header\"\u003eDownloads\u003c\/span\u003e\n\u003cdiv class=\"downloads-section\"\u003e\n\u003cdiv class=\"pdf-button\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_6230A_Accurate-Mass_TOF_Mass_Spectrometer_-_Marshall_Scientific.pdf?v=1779985761\"\u003e Technical Specification Download \u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"pdf-button\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_6230A_Accurate-Mass_TOF_Mass_Spectrometer_Manual_-_Marshall_Scientific.pdf?v=1779985766\"\u003e Operator's Manual Download \u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"pdf-button\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_6200_Series_TOF_Mass_Spectrometers_Site_Preparation_Guide_-_Marshall_Scientific.pdf?v=1779985769\"\u003e Site Prep Guide Download \u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"formalquote2\"\u003e\u003ca class=\"formalquote2link\" href=\"\/formal_quote_a\/2952.htm\"\u003eRequest a Formal Quote\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"My Store","offers":[{"title":"Default Title","offer_id":42474494951514,"sku":"AG-6230AMS1260","price":94995.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-6230AMS1260-2T.jpg?v=1780432956"},{"product_id":"agilent-6230b-accurate-mass-tof-mass-spectrometer-w-1260-infinity-i-lc-system","title":"Agilent 6230B Accurate-Mass TOF Mass Spectrometer w\/ 1260 Infinity I LC System","description":"\u003cdiv class=\"productdescriptiontables\"\u003e\n\t\u003ch1\u003eAgilent 6230B Accurate-Mass TOF Mass Spectrometer w\/ 1260 Infinity I LC System\u003c\/h1\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-section\"\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eMass Range\u003c\/b\u003e\u003cbr\u003em\/z 25 to 20,000\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eMass Accuracy\u003c\/b\u003e\u003cbr\u003e\u0026lt; 1 ppm (measured at m\/z 609.2807)\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eSpectral Acquisition Rate\u003c\/b\u003e\u003cbr\u003e30 spectra\/second (from m\/z 100 to 3,200)\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"features-section\"\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cspan class=\"features-header\"\u003eFeatures\u003c\/span\u003e\n\t\t\t\u003cul\u003e\n\t\t\t\t\u003cli\u003eOrthogonal acceleration TOF design for enhanced resolution and minimized entrance velocity effects\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eAgilent Jet Stream ESI technology for increased ionization efficiency and low picogram sensitivity\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eDynamic range spanning five orders of magnitude for detecting trace-level compounds in complex matrices\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eAutomated tuning and calibration for consistent performance and reduced user intervention\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eReal-time internal reference mass correction with built-in calibrant delivery system\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eResolving power of 22,000 FWHM for separating closely related compounds\u003c\/li\u003e\n\t\t\t\t\u003cli\u003ePolarity switching in under 1 second for versatile positive and negative ion analysis\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eSingle-point data control for seamless integration with HPLC systems and error management\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eOptional in-source dissociation for untargeted screening and enhanced fragmentation data\u003c\/li\u003e\n\t\t\t\u003c\/ul\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-6230.jpg?v=1779985757\"\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\n\tThe Agilent 6230B Accurate-Mass TOF Mass Spectrometer w\/ 1260 Infinity I LC System is a high-performance time-of-flight (TOF) system designed to provide precise, high-resolution mass measurements for a wide range of applications, including drug discovery, metabolomics, and environmental analysis. Utilizing orthogonal acceleration (oa-TOF) technology, this instrument directs ions perpendicularly to their original trajectory before they enter the flight tube, reducing entrance velocity effects and enhancing resolution. With its ability to capture a full mass spectrum scan up to 20,000 m\/z, the 6230B delivers superior analytical capabilities, allowing for accurate identification of unknown compounds, advanced statistical analysis, and in-depth biomolecule characterization. Equipped with Agilent Jet Stream (AJS) electrospray ionization (ESI) technology, the system enhances ion generation and transmission efficiency through a super-heated sheath gas, significantly increasing sensitivity while maintaining low detection limits. The 6230B ensures high-throughput sample screening with superior mass accuracy, reducing false positives with a precision of better than 1 ppm. This precision is maintained even in demanding workflows, supported by a high spectral acquisition rate of up to 30 spectra per second, enabling robust performance for fast ultra-high-performance liquid chromatography (UHPLC) separations.\n\t\u003cbr\u003e\u003cbr\u003e\n\tThe Agilent 6230B also offers advanced molecular profiling tools through the intuitive MassHunter software suite, featuring Find by Formula for compound identification based on accurate mass, isotopic abundance, and chemical composition. Additionally, the system supports high-resolution separation of complex mixtures, enabling confident elemental formula determination. With a broad dynamic range of up to five orders of magnitude, this TOF mass spectrometer can detect trace-level analytes even in complex matrices, making it a powerful tool for impurity profiling and advanced biological analysis. Designed for versatility, the 6230B supports multiple ionization sources, including ESI, atmospheric pressure chemical ionization (APCI), atmospheric pressure photoionization (APPI), multimode (ESI and APCI), HPLC-Chip\/MS interface, and AP\/MALDI PDF+ sources. It incorporates a dual-sprayer orthogonal ESI source with a built-in calibrant delivery system, allowing for real-time internal reference mass correction. The system's single-point data control integrates HPLC and TOF operations, automatically stopping sample injections if errors or leaks occur, improving workflow efficiency and reducing operational risks.\n\t\u003cbr\u003e\u003cbr\u003e\n\tWith a resolving power of 22,000 full width at half maximum (FWHM) and a mass accuracy stability of 2 ppm even with temperature fluctuations, the Agilent 6230B provides consistently high-quality data. The system’s automated tuning and calibration capabilities optimize ion optics and TOF MS mass axis alignment, ensuring peak performance with minimal user intervention. For laboratories requiring untargeted screening, the system offers optional in-source dissociation for fragmentation data, further expanding its analytical capabilities. Built to streamline laboratory operations, the Agilent 6230B features MassHunter software, simplifying workflows and minimizing administrative tasks while enabling efficient, expert-level analysis without the need for extensive LC\/MS expertise. Whether analyzing monoclonal antibodies, glycoforms, truncations, or other biologic compounds, the Agilent 6230B provides unparalleled accuracy, resolution, and sensitivity, making it an essential instrument for laboratories seeking cutting-edge mass spectrometry performance.\n\t\u003cbr\u003e\u003cbr\u003e\u003cb\u003eThis Agilent LC\/MS system was recertified and calibrated by a factory trained engineer and is ready to ship on demand. This system comes with everything needed for easy installation and setup. All of our equipment is fully tested to perform at factory specifications before being shipped.\u003c\/b\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"included-box\"\u003e\n\t\t\u003cspan class=\"included-header\"\u003eINCLUDED:\u003c\/span\u003e\u003cbr\u003eThe Agilent 6230B Accurate-Mass TOF Mass Spectrometer w\/ 1260 Infinity I LC System includes:\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eAgilent 6230B Single Quadrupole Mass Spectrometer\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eAgilent MS40+ Rotary Vane Vacuum Pump\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eAgilent G1958B Jet Stream Electrospray Ionization Source\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eG1312B Binary Pump (G1311B Quaternary Pump available, please inquire)\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eG1329B Autosampler\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eG1330B ALS Thermostat\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eG1316A TCC \u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eG1379B Degasser\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eG4212B DAD Detector\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eWindows 10 Professional 64-Bit Data Station with Flatscreen Monitor\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eAgilent MassHunter B.09.01 Acquisition and Data Analysis Software Installed\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eAgilent MassHunter BioConfirm Software Installed\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eAll Power Cords\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eCan\/Crossover Cables\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eAgilent Lan Interface Card Built-In\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eSolvent Tubing\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eCapillaries\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eAgilent 4 Peak Test w\/ Lab Advisor Diagnostics Report \u0026amp; Mass Spec Tuning Report\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eFull 180 Day Parts and Labor Warranty\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"agilent-tests\"\u003e\n\t\t\u003cspan class=\"agilent-tests-title\"\u003eBelow is a List of Diagnostic Tests Performed On This LC System\u003c\/span\u003e\u003cbr\u003e\n\t\t\u003cspan class=\"agilent-tests-header\"\u003eG4212B Diode Array Detector Diagnostic Tests:\u003c\/span\u003e\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003eFilter Test: The test moves the filter into the light path and measures the relative absorbance in the filter position.\u003c\/li\u003e\n\t\t\t\u003cli\u003eDark Current Test: The test measures the dark current from the detector optic.\u003c\/li\u003e\n\t\t\t\u003cli\u003eHolmium Oxide Test: The test measures the Holmium spectrum from the built-in Holmium filter. The spectrum is evaluated for peaks at different wavelengths.\u003c\/li\u003e\n\t\t\t\u003cli\u003eLamp Intensity Test: The test verifies functionality of the UV lamp at various wavelengths.\u003c\/li\u003e\n\t\t\t\u003cli\u003eWavelength Intensity Test: The test confirms the accuracy of wavelengths measured.\u003c\/li\u003e\n\t\t\t\u003cli\u003e Baseline Noise Test: The test measures the amount of baseline noise drift identified by the detector.\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\t\u003cspan class=\"agilent-tests-header\"\u003eG1312B Binary Pump Diagnostic Tests:\u003c\/span\u003e\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003ePressure Test: The pressure test is a quick, built-in test designed to demonstrate the pressure tightness (up to 400 bar) of the system.\u003c\/li\u003e\n\t\t\t\u003cli\u003eLeak Test: The leak test is a built-in troubleshooting designed to demonstrate the leak-tightness of the pump.\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\t\u003cspan class=\"agilent-tests-header\"\u003eG1316A Column Compartment Diagnostic Tests:\u003c\/span\u003e\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003eThermostat Test: Evaluates the cooling and heating performance of the two Peltier elements.\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\t\u003cspan class=\"agilent-tests-header\"\u003eG1329B Autosampler Diagnostic Tests:\u003c\/span\u003e\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e Injector Steps: Performs each movement of the sampling sequence under manual control. This is useful for confirming autosampler functionality.\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\t\u003cspan class=\"agilent-tests-header\"\u003eSystem Tests:\u003c\/span\u003e\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e4 Peak Test (Isocratic Standard): Standard test published by Agilent to confirm complete functionality of the 1260 Infinity I LC System.\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003ch2\u003eAgilent 6230B Accurate-Mass TOF Mass Spectrometer Specifications\u003c\/h2\u003e\n\t\u003ctable\u003e\n\t\u003ctbody\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tMS Sensitivity with AJS (Included)\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tSignal-to-noise ratio \u0026gt; 50:1, Noise = 1 × RMS (1 pg reserpine injected on-column, measured at m\/z 609.2807)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tMS Sensitivity with ESI (Option 200)\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tSignal-to-noise ratio \u0026gt; 10:1, Noise = 1 × RMS (1 pg reserpine injected on-column, measured at m\/z 609.2807)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tMass Resolving Power\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t22,000 FWHM (measured at m\/z 1,522 after automatic tuning procedure)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tMass Accuracy - MS Mode\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u0026lt; 1 ppm (measured at m\/z 609.2807 using an internal reference mass)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tSpectral Acquisition Rate - MS Mode\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t30 spectra\/second (spectra acquisition from m\/z 100 to 3,200)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDynamic Range\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tUp to 5 decades (in-scan dynamic range on co-eluting components)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tMass Range\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tm\/z 25 to 20,000\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tPolarity Switching\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u0026lt; 1 sec (pos\/neg switching)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tMass Accuracy Temperature Stability - MS Mode\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tMaintain 2 ppm mass accuracy within 2°C drift per hour (temperature: 15°C to 35°C (59°F to 95°F) at constant temperature while setting autotune at 25°C)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tSingle Point of Control\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tSingle point data system method capability with full control for HPLC system and TOF, stopping sample injection if errors or leaks occur\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tIonization sources\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tElectrospray (ESI), Atmospheric pressure chemical ionization (APCI), Atmospheric pressure photoionization (APPI), Multimode source (ESI and APCI), HPLC-Chip\/MS interface, AP\/MALDI PDF+ source\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tTransparent Introduction of Reference Masses\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tDual-sprayer orthogonal ESI source, built-in calibrant delivery system, real-time internal reference mass correction for MS operation and heated sources\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tAutotune\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tAutomated optimization of ion optics and full TOF MS mass axis calibration\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tData Mining Tools\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tOne-button extraction of compound-specific spectral and chromatographic information using find compounds algorithms\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tMolecular Profiling Tools\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tMeasurement of molecular features from LC\/MS analyses (MassHunter), differential expression analysis with optional MassHunter Mass Profiler\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tSound Emission\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u0026lt; 70 db\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDimensions (L x W x H)\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t32.7 x 28.7 x 52.4 in. (83 x 73 x 133 cm)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tWeight\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t260 lb. (117.9 kg)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tElectrical Requirements\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t200-220VAC, 50\/60Hz, 15A\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\t\u003c\/table\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"show-hidden-table\"\u003e\nClick Here to View Specifications for the Agilent 1260 Infinity I LC System\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\n\t\u003cdiv class=\"hidden-table\"\u003e\n\t\t\u003ctable\u003e\n\t\t\u003ctbody\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cstrong\u003eDAD Detector\u003c\/strong\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cstrong\u003eSpecification\u003c\/strong\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tDetection Type\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t1024-element photodiode array\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tLight Source\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tDeuterium and tungsten lamps\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tWavelength Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t190 - 640 nm\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tShort Term Noise (ASTM) Single and Multi-Wavelength\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t± 3 × 10 \n\t\t\t\t\u003csup\u003e-6\u003c\/sup\u003e AU at 230 nm\/4 nm\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tDrift\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u0026lt; 0.5 × 10 \n\t\t\t\t\u003csup\u003e-3\u003c\/sup\u003e AU\/hr at 230 nm\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tLinear Absorbance Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u0026gt; 2.0 AU (5%) at 265 nm\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tWavelength Accuracy\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t± 1 nm\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tWavelength Bunching\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t1 - 400 nm\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tSlit Width\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t4 nm\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tDiode Width\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t~ 0.5 nm\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tFlow Cell\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cp\u003e\n\t\t\t\t\tStandard: 13 µL volume, 10 mm cell path length and 120 bar (1740 psi) pressure maximum\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cstrong\u003eBinary Pump\u003c\/strong\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cstrong\u003eSpecification\u003c\/strong\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tHydraulic System\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tTwo dual piston in series pumps with proprietary servo-controlled variable stroke drive, power transmission by gears and ball screws, floating pistons\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tSetable Flow Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t0.001 – 5 ml\/min, in 0.001 ml\/min increments\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tFlow Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cp\u003e\n\t\t\t\t\t0.5 - 5.0 mL\/min\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tFlow Precision\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t≤ 0.07% RSD or ≤ 0.02 min SD, whatever is greater\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tFlow Accuracy\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t± 1% or 10 µl\/min, what ever is greater\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tPressure Operating Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tOperating range 0 to 600 bar (0 – 7800 psi) up to 5 ml\/min\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tPressure Pulsation\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u0026lt; 2 % amplitude (typically \u0026lt; 1.3 %), or \u0026lt; 0.3 MPa (3 bar), whatever is greater, at 1 mL\/min isopropanol, at all pressures \u0026gt; 1 MPa (10 bar, 147 psi)\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tCompressibility Compensation\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tUser-selectable, based on mobile phase compressibility\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tRecommended pH Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t1.0 - 12.5, solvents with pH \u0026lt; 2.3 should not contain acids which attack stainless stee\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tGradient Formation\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tHigh-pressure binary mixing\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tDelay Volume\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t600 to 800 µl, dependent on back pressure\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tComposition Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t0 to 100% (1 to 99% or 5 µl\/min per channel, whatever is greater is recommended)\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tComposition Precision\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u0026lt; 0.15% RSD or \u0026lt; 0.04 min SD whatever is greater\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tComposition Accuracy\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t± 0.35% absolute at 2 mL\/min, at 10 MPa (100 bar)\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cstrong\u003eAutosampler\u003c\/strong\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cstrong\u003eSpecification\u003c\/strong\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tInjection Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t0.1 - 100 µl in 0.1 µl increments\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tPrecision\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cp\u003e\n\t\t\t\t\t\u0026lt; 0.25 % RSD of peak areas from 5 to 100 µl\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\t\u003cp\u003e\n\t\t\t\t\t\u0026lt; 1 % RSD of peak areas from 1 to 5 µl\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tPressure Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tOperating range 0 - 60 MPa (0 - 600 bar, 0 - 8850 psi)\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tSample Viscosity Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t0.2 to 50 cp\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tSample Capacity\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t100 × 2 mL vials in 1 tray\n\t\t\t\t\u003cbr\u003e40 × 2 mL vials in ½ tray\u003cbr\u003e15 × 6 mL vials in ½ tray (Agilent vials only)\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tInjection Cycle Time\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t50 s for draw speed 200 µL\/min, ejection speed 200 µL\/min, injection volume 5 µL\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tCarryover\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tTypically \u0026lt; 0.1 %, \u0026lt; 0.05 % with external needle cleaning\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cstrong\u003eALS Thermostat\u003c\/strong\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cstrong\u003eSpecification\u003c\/strong\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tTemperature Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t4°C to 40°C in 1°C increments\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tTemperature Accuracy at Ambient Temperatures \u0026lt; 25°C and Humidity \u0026lt; 50%\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t3°C to +8°C at a setpoint of 4°C\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tTemperature Accuracy at Ambient Temperatures \u0026gt; 30°C and Humidity \u0026gt; 60%\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t3°C to +9°C at a setpoint of 4°C\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cstrong\u003eColumn Compartment\u003c\/strong\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cstrong\u003eSpecification\u003c\/strong\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tTemperature Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tAmbient -10°C to 80°C at flow rates up to 5 mL\/min\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tTemperature Stability\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t± 0.15 °C\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tTemperature Accuracy\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t± 0.8°C (± 0.5°C with calibration)\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tColumn Capacity\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tThree 30 cm\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tWarm-Up\/Cool-Down Time\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t5 minutes from ambient to 40°C\n\t\t\t\t\u003cbr\u003e10 minutes from 40°C to 20°C\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tDead Volume\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cp\u003e\n\t\t\t\t\t3 µl left heat exchanger\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\t\u003cp\u003e\n\t\t\t\t\t6 µl right heat exchanger\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cstrong\u003eDegasser\u003c\/strong\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cstrong\u003eSpecification\u003c\/strong\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tNumber of Solvent Channels\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t4\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tMaximum Flow Rate\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t0 - 5 mL\/min per channel\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tInternal Volume Per Channel\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tTypically 1 ml per channel\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tMaterials in Contact with Solvent\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tPTFE, PEEK\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tpH Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t1 - 14\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003c\/tbody\u003e\n\t\t\u003c\/table\u003e\n\t\t\u003cbr\u003e\u003cbr\u003e\n\t\t\u003ctable\u003e\n\t\t\u003ctbody\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd colspan=\"2\" width=\"623\"\u003e\n\t\t\t\t\u003cp style=\"text-align: center;\"\u003e\n\t\t\t\t\tComputer Specifications\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cp\u003e\n\t\t\t\t\tModel\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cp\u003e\n\t\t\t\t\tDell Optiplex 7010 Desktop PC\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cp\u003e\n\t\t\t\t\tProcessor\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cp\u003e\n\t\t\t\t\tIntel Core i5-6500 Processor 3.2GHz\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cp\u003e\n\t\t\t\t\tRAM\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cp\u003e\n\t\t\t\t\t16GB\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cp\u003e\n\t\t\t\t\tHard Drive\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cp\u003e\n\t\t\t\t\t250GB Internal SSD\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cp\u003e\n\t\t\t\t\tOperating System\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cp\u003e\n\t\t\t\t\tWindows 10 Professional, 64bit\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003c\/tbody\u003e\n\t\t\u003c\/table\u003e\n\t\u003c\/div\u003e\n\t\u003cspan class=\"downloads-header\"\u003eDownloads\u003c\/span\u003e\n\t\u003cdiv class=\"downloads-section\"\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_6230B_Accurate-Mass_TOF_Mass_Spectrometer_-_Marshall_Scientific.pdf?v=1779985776\" target=\"blank\"\u003e\n\t\t\tTechnical Specification Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_6230B_Accurate-Mass_TOF_Mass_Spectrometer_Manual_-_Marshall_Scientific.pdf?v=1779985780\" target=\"blank\"\u003e\n\t\t\tOperator's Manual Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"formalquote2\"\u003e\n\t\t\u003ca class=\"formalquote2link\" href=\"\/formal_quote_a\/2875.htm\" target=\"blank\"\u003eRequest a Formal Quote\u003c\/a\u003e\n\t\u003c\/div\u003e\n\u003c\/div\u003e","brand":"My Store","offers":[{"title":"Default Title","offer_id":42474495148122,"sku":"AG-6230BLCMS1260","price":102995.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-6230BLCMS1260-2.jpg?v=1761206738"}],"url":"https:\/\/p2gnpt-0c.myshopify.com\/collections\/mass-spectrometry\/mass-range_10-to-1350-m-z.oembed","provider":"Marshall Scientific","version":"1.0","type":"link"}