Need help selecting a product? Use our new filter tool to help you find the right product.
Most Products Ship Same Day
with Free Shipping
Prime Deals From Our Partners!
Grab Yours Today: Click Here!
Ohaus Buy Get Promotion: Centrifuges & Balances.

| Readability | 1 mg / 0.01% |
| Weighing Capacity | 40 g |
| Typical Reproducibility of the Weighing System | Starting at an initial sample weight of approx. 1 g: ± 0.2% Starting at an initial sample weight of approx. 5 g: ± 0.05% |
| Method of Measurement | Thermogravimetric; loss on drying |
| Recommended Moisture Range | 1.00–99.90% |
| Heat Source | Four parallel infrared quartz cylinders |
| Modular Extension | Optional; up to 2 heater modules connectable |
| Data Printer | Optional internal thermal printer; 40 characters |
| Temperature Range and Adjustment | 30–210°C in one-degree increments |
| Temperature Steps | Programmable; one or two |
| Standby Temperature | Standby temperature selectable from 30–160°C |
| Temperature Display | Display of target temperature and actual temperature during the measurement and in standby mode |
| Display Modes | Weight loss in mg, % moisture, % dry weight, % volatiles |
| Modes of Operation | Standard or concentration mode |
| Endpoint Determination | Timer mode; when value falls below a defined weight loss per time unit (%/min); trend shutoff |
| Program | 60 programs; battery-backed memory |
| Data Storage | Results with statistics of the last 999 measurements: average, SD, RSD, min and max |
| Temperature Adjustment | Optional set for internal electronic two-point adjustment |
| Adjustment of the Weighing System | Manual calibration and adjustment using an external weight |
| Ideal Initial Weight | Audio and visual display for programmable weighing of a sample to an initial target |
| Pass-Fail Function | Programmable target value, including limits; pass-fail information at the end of a measurement |
| Display | Backlit VGA display |
| Real-Time Curves | Real-time curves of the loss in weight (% or grams) as well of the temperature curves during and after the measurement |
| System Status Indicator Lights | Two tricolor LEDs (balance & heater) on front of heater module |
| Interfaces | Serial and Ethernet; USB for service |
| Weighing System | Monolithic weighing system for high-precision results |
| Dimensions (W x D x H) | 16.3 x 19.5 x 9.3 in. (41.3 x 49.5 x 23.5 cm), modules combined |
| Weight | 22 lb. (10 kg), modules combined |
| Electrical Requirements | 90-250 VAC, 50/60Hz, self-adjusting power supply |

| Readability | 0.1 mg / 0.001% |
| Weighing Capacity | 100 g |
| Typical Reproducibility of the Weighing System | Starting at an initial sample weight of approx. 1 g: ± 0.1% Starting at an initial sample weight of approx. 5 g: ± 0.02% |
| Method of Measurement | Thermogravimetric; loss on drying |
| Recommended Moisture Range | 0.001 - 99.999% |
| Heat Source | Four parallel infrared quartz cylinders |
| Modular Extension | Optional; up to 4 heater modules connectable |
| Data Printer | Integrated thermal printer; 40 characters |
| Temperature Range and Adjustment | 30-210°C in one-degree increments |
| Temperature Steps | Programmable; one or two with selectable ramp rate |
| Standby Temperature | Standby temperature selectable from 30-160°C |
| Temperature Display | Display of target temperature and actual temperature during the measurement and in standby mode |
| Display Modes | Weight loss in mg, % moisture, % dry weight, % volatiles, ppm moisture, ppm dry weight, concentration mg/L |
| Modes of Operation | Standard, syringe, concentration or 2-phase drying mode |
| Endpoint Determination | Timer mode; when value falls below a defined weight loss per time unit (%/min); trend shutoff |
| Program | 300 programs; battery-backed memory |
| Data Storage | Results with statistics of the last 999 measurements: average, SD, RSD, min and max |
| Temperature Adjustment | Optional set for internal electronic two-point adjustment |
| Adjustment of the Weighing System | Internal calibration weight or manual calibration and adjustment using an external weight |
| Ideal Initial Weight | Audio and visual display for programmable weighing of a sample to an initial target |
| Pass-Fail Function | Programmable target value including limits; pass-fail information at the end of a measurement |
| Display | Backlit VGA display |
| Real-Time Curves | Real-time curves of the loss in weight (% or grams) as well of the temperature curve during and after the measurement |
| System Status Indicator Lights | Two tricolor LEDs (balance & heater) on front of heater module |
| Interfaces | Serial and Ethernet; USB for service |
| Weighing System | Monolithic weighing system for high-precision results |
| Dimensions (W x D x H) | 16.3 x 19.5 x 9.3 in. (41.3 x 49.5 x 23.5 cm), modules combined |
| Weight | 22 lb.(10 kg), modules combined |
| Electrical Requirements | 90-250 VAC, 50/60Hz, self-adjusting power supply |