Find by Price
Find by Agilent HPLC Component Series
Find by Agilent HPLC System Series
Find by AKTA FPLC System Series
Find by Application Capabilities
Find by Aspiration Rate
Find by Aspiration Speed
Find by Autoclave Chamber Volume
Find by Balance Capacity
Find by Balance Readability
Find by Balance Type
Find by Block Configuration
Find by Blowdown Evaporator Capacity
Find by Brand
Find by Cell Size Range
Find by Cell Washing Capability
Find by Centrifugal Evaporator Compatibility
Find by Centrifugal Evaporator Maximum Speed
Find by Centrifugal Evaporator Refrigeration
Find by Centrifuge Compatibility
Find by Centrifuge RCF
Find by Centrifuge Refrigeration
Find by Centrifuge Type
Find by Chiller Cooling Capacity
Find by Chiller Flow Rate
Find by Chiller Lowest Temperature
Find by Cold Trap Temperature
Find by Concentration Range
Find by Detectors Included
Find by Dry Bath Heater Capacity
Find by Dry Bath Heater with Cooling
Find by FPLC Component Type
Find by FPLC System Flow Rate Range
Find by FPLC System Pressure Range
Find by Freeze Dryer Accessory Type
Find by Freeze Dryer Material
Find by Freeze Dryer Size
Find by Freeze Dryer Temperature
Find by Freeze Dryer Voltage
Find by Freezer Capacity
Find by Freezer Low Temperature
Find by Freezer Style
Find by Glassware Washer Style
Find by Gradient Function
Find by Head Type
Find by Histology Centrifuge Maximum Speed
Find by Hotplate Stirrer Maximum Temperature
Find by Hotplate Stirrer Speed Range
Find by Hotplate Stirrer Type
Find by HPLC Component Type
Find by Includes Stoppering or Bulk Tray Dryer
Find by Incubator Capacity
Find by Incubator Refrigeration
Find by Incubator Shaker Refrigeration
Find by Incubator Type
Find by Integrated Vacuum Pump
Find by Liquid Sterilization?
Find by Mass Range
Find by Maximum Current
Find by Maximum Dry Bath Heater Temperature
Find by Maximum Flask Size
Find by Maximum Heating Bath Flask Size
Find by Maximum Heating Bath Temperature
Find by Maximum Incubator Shaker Speed
Find by Maximum Incubator Shaker Temperature
Find by Maximum Incubator Temperature
Find by Maximum Mixer Speed
Find by Maximum Oven Temperature
Find by Maximum Pumping Speed
Find by Maximum Rotary Evaporator Temperature
Find by Maximum RT-PCR Ramp Rate
Find by Maximum Voltage
Find by Maximum Vortexer Speed
Find by Maximum Water Bath Temperature
Find by Maximum Watts
Find by Microplate Reader Capability
Find by Microplate Types
Find by Mixer Type
Find by Multiple Buffer Capability
Find by Oven Capacity
Find by Oven Type
Find by Peristaltic Pump Flow Rate Range
Find by Pipette Type
Find by Pipette Volume
Find by Refrigerator Capacity
Find by Refrigerator Low Temperature
Find by Refrigerator Style
Find by Reservoir Size
Find by Rotor Type
Find by Shaker Speed Control
Find by Shaker Type
Find by Spectrophotometer Absorbance Wavelength Range
Find by Spectrophotometer Capability
Find by Thermal Bead Compatibility
Find by Thermal Mixer Cooling Capability
Find by Thermal Mixer Maximum Speed
Find by Thermal Range
Find by Ultimate Vacuum
Find by Ultrasonic Capability
Find by Vacuum Pump Type
Find by Vortexer Type
Find by Water Bath Size
New Lab Equipment

Cytiva AKTA Pure 25 M FPLC System
Cytiva AKTA Pure 25 M FPLC System Specifications
|
|
|
|
Flow Rate Range |
0.001 to 25 ml/min (up to 50 ml/min during column packing) |
|
Flow Rate Accuracy |
± 1.2% |
|
Flow Rate Precision |
RSD <0.5% |
|
Pressure Range |
0 to 20 MPa (2900 psi) |
|
Pressure Limits |
Programmable upper and lower |
|
Viscosity Range |
0.35 to 10 cP (5 cP above 12.5 ml.min) |
|
|
|
|
Wavelength Range |
190 to 700 nm in steps of 1 nm, up to 3 wavelengths |
|
Absorbance Range |
-6 to 6 AU |
|
Resolution |
0.001 mAU |
|
Wavelength Reproducibility |
± 0.01 nm |
|
Linearity |
Within ± 2% at 0 to 2 AU |
|
Drift |
≤ | 0.2 mAU | AU/h (2 mm cell at 280 nm) |
|
Noise |
< 0.08 mAU |
|
Operating Pressure |
0 to 2 MPa |
|
Lamp Operating Time |
> 5000 hours |
|
Flow Cell |
Optical path length: 2 mm Cell volume: 2 ul Total volume: 11 ul |
|
|
|
|
Conductivity Range |
0.01 to 999.9 mS/cm |
|
Accuracy |
± 0.01 mS/cm or ± 2%, whichever is greater (within 0.3 to 300 mS/cm) |
|
Operating Pressure |
0 to 5 MPa |
|
Flow Cell Volume |
22 ul |
|
Temperature Monitor Range |
0°C to 99°C |
|
Temperature Monitor Accuracy |
± 1.5°C within 4°C to 45°C |
|
|
|
|
pH Reading Range |
0 to 14 |
|
Accuracy |
± 0.1 pH unit within pH 2 to 12, temperature within ± 3°C from calibration temperature |
|
Operating Pressure |
0 to 0.5 MPa |
|
Flow Cell Volume |
76 ul |
|
|
|
|
Number of Fractions |
Up to 576 |
|
Vessel Types |
Deep well plates, 96, 48, or 24 wells |
|
Fraction Volumes |
0.1 to 250 ml
|
|
Spillage-Free Mode |
Automatic, Drop Sync, or Accumulator |
|
Flammable Liquids |
No |
|
Delay Volume (UV-Dispenser Head) |
205 ul, 86 ul with optional tubing kit (i.d. 0.25 mm) |
|
Dimensions (W x D x H) |
15.4 x 23 x 12.6 (39 x 58.5 x 32 cm) |
|
Weight |
46.3 lb. (21 kg) |