{"title":"Real-Time PCR Systems","description":"","products":[{"product_id":"applied-biosystems-7500-real-time-pcr-system","title":"Applied Biosystems 7500 Real-Time PCR System","description":"\u003cdiv class=\"productdescriptiontables\"\u003e\n\t\u003ch1\u003eApplied Biosystems 7500 Real-Time PCR System\u003c\/h1\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-section\"\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eBlock Configuration\u003c\/b\u003e\u003cbr\u003e96-Well\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eMaximum Ramp Rate\u003c\/b\u003e\u003cbr\u003e2.5°C\/second\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eTemperature Uniformity\u003c\/b\u003e\u003cbr\u003e± 0.5°C\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"features-section\"\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cspan class=\"features-header\"\u003eFeatures\u003c\/span\u003e\n\t\t\t\u003cul\u003e\n\t\t\t\t\u003cli\u003eHighly suitable for a variety of applications including gene expression analysis and DNA quantification\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eIntegrated real-time PCR solutions with optimized reagents and customizable assays\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eCapable of delivering results in less than 2 hours\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eOptical system includes CCD camera and halogen lamp with five excitation and emission filters\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eSupports multiplexing of up to five targets per well\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eFeatures a dynamic range of nine logs\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eSensitivity to detect one copy of a template in 50 uL reactions with 99.7% confidence\u003c\/li\u003e\n\t\t\t\u003c\/ul\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AB-7500F_36e391f5-c726-4d39-b288-8f0b1b307268.jpg?v=1779986097\"\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003eThe Applied Biosystems 7500 Real-Time PCR System is designed for advanced PCR applications, ideal for genetic analysis and molecular diagnostics. This system features a robust 96-well block, supporting reaction volumes from 20 to 100 uL, optimized for precise and efficient thermal cycling. Key characteristics of the system include a temperature range of 4°C to 100°C, ensuring broad flexibility for various assays. The temperature uniformity is maintained at ± 0.5°C, achieved 30 seconds after the cycle starts, with an accuracy of ± 0.25°C, measured three minutes after the cycle begins. This precision is critical for consistent results across all wells.\n\t\u003cbr\u003e\u003cbr\u003e\n\tThe system boasts a maximum ramp rate of 2.5°C per second, enabling completion of runs in less than two hours. Its optical setup includes a CCD camera and a halogen lamp for excitation, accompanied by five excitation and emission filters that allow for sensitive multiplex detection of up to five targets per well. With a dynamic range spanning nine logs, the 7500 system can detect a single copy of a template in a 50 uL reaction volume with 99.7% confidence. This sensitivity makes it an indispensable tool for laboratories requiring reliable, high-throughput PCR capabilities. \u003cb\u003ePlease Note: We recommend performing a Dye Calibration for the Dye you plan on using for your application(s). Please refer to the Operator's Manual for instructions.\u003c\/b\u003e\n\t\u003cbr\u003e\u003cbr\u003eAll of our equipment is fully tested to perform at factory specifications before being shipped.\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"included-box\"\u003e\n\t\t\u003cspan class=\"included-header\"\u003eINCLUDED:\u003c\/span\u003e\u003cbr\u003eThe Applied Biosystems 7500 Real-Time PCR System includes:\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003e96-Well Block\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eNew Halogen Lamp\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eBackground Calibration Report\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eROI Calibration Report\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eOptical Calibration Report\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eWindows 11 Professional 64-Bit Data Station\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eApplied Biosystems 7500 Software Installed\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003ePower Cord\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eOperator's Manual\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eFull 180 Day Parts and Labor Warranty\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\n\t\u003ch2\u003eApplied Biosystems 7500 Real-Time PCR System Specifications\u003c\/h2\u003e\n\t\u003ctable\u003e\n\t\u003ctbody\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tBlock Configuration\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t96-Well (20 to 100 uL reactions)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tTemperature Range\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t4°C to 100°C\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tTemperature Uniformity\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t± 0.5°C (30 seconds after clock start)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tTemperature Accuracy\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t± 0.25°C of setpoint\/display temperature (measured at 3 minutes after clock start)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tMaximum Ramp Rate\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t2.5°C\/second\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tRun Time\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u0026lt; 2 hours\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tOptical System\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tCCD camera with halogen lamp excitation; five-exciation and five-emission filters\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDynamic Range\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t9 logs of linear dynamic range\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tSensitivity\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tDetection of 1 copy of template in 50 uL reaction for a single reporter TaqMan assay, with 99.7% confidence\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tMultiplexing\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tUp to 5 targets per well\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDye Compatibility\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tFAM\/SYBR Green, VIC\/JOE, NED\/TAMRA\/Cy3, ROX\/Texas Red, and Cy5 (Calibration for new dyes within the wavelength range is possible by following the custom dye calibration procedure in the user’s manual)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tPassive Reference Dyes\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tROX dye or any calibrated dye\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDimensions (W x D x H)\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t13.9 x 17.7 x 19.3 in. (34 x 45 x 49 cm)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tWeight\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t75 lb. (34 kg)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tElectrical Requirements\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t100-240V, 50\/60Hz, 1080W\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\t\u003c\/table\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003ctable\u003e\n\t\u003ctbody\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd colspan=\"2\"\u003e\n\t\t\t\u003ccenter\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t\tComputer Specifications\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003c\/center\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\tProcessor\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\tIntel Core I5-8350U CPU\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\tRAM\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t16.0 GB\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\tHard Drive\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\t512GB Internal SSD\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\tOperating System\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\tWindows 11 Professional, 64-bit\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\t\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cspan class=\"downloads-header\"\u003eDownloads\u003c\/span\u003e\n\u003cdiv class=\"downloads-section\"\u003e\n\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Applied_Biosystems_7500_Fast_Real-Time_PCR_System_-_Marshall_Scientific.pdf?v=1779986124\" target=\"blank\"\u003e\n\t\tTechnical Specification Download\n\t\t\u003c\/a\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Applied_Biosystems_7500_Fast_Real-Time_PCR_System_Manual_-_Marshall_Scientific.pdf?v=1779986120\" target=\"blank\"\u003e\n\t\tOperator's Manual Download\n\t\t\u003c\/a\u003e\n\t\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"formalquote2\"\u003e\n\t\u003ca class=\"formalquote2link\" href=\"\/formal_quote_a\/2884.htm\" target=\"blank\"\u003eRequest a Formal Quote\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cspan class=\"windows11\"\u003e\u003c\/span\u003e","brand":"My Store","offers":[{"title":"Default Title","offer_id":42474430791770,"sku":"AB-7500","price":7495.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AB-7500-2.jpg?v=1761203746"},{"product_id":"applied-biosystems-7500-fast-real-time-pcr-system","title":"Applied Biosystems 7500 Fast Real-Time PCR System","description":"\u003cdiv class=\"productdescriptiontables\"\u003e\n\t\u003ch1\u003eApplied Biosystems 7500 Fast Real-Time PCR System\u003c\/h1\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-section\"\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eBlock Configuration\u003c\/b\u003e\u003cbr\u003e96-Well Fast\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eMaximum Ramp Rate\u003c\/b\u003e\u003cbr\u003e5.5°C\/second\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eTemperature Uniformity\u003c\/b\u003e\u003cbr\u003e± 0.5°C\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"features-section\"\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cspan class=\"features-header\"\u003eFeatures\u003c\/span\u003e\n\t\t\t\u003cul\u003e\n\t\t\t\t\u003cli\u003eFast cycling technology allows for more runs to be completed per day\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eFaster ramp rates enable quick temperature changes without sacrificing performance\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eHighly suitable for a variety of applications including gene expression analysis and DNA quantification\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eIntegrated real-time PCR solutions with optimized reagents and customizable assays\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eCapable of delivering results in less than 30 minutes\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eOptical system includes CCD camera and halogen lamp with five excitation and emission filters\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eSupports multiplexing of up to five targets per well\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eFeatures a dynamic range of nine logs\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eSensitivity to detect one copy of a template in 20 µL reactions with 99.7% confidence\u003c\/li\u003e\n\t\t\t\u003c\/ul\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AB-7500F_36e391f5-c726-4d39-b288-8f0b1b307268.jpg?v=1779986097\"\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003eThe Applied Biosystems 7500 Fast Real-Time PCR System stands at the forefront of PCR technology, offering unparalleled speed and precision for the detection and quantification of nucleic acids. This system, built on over ten years of real-time PCR innovation, is tailored for high-throughput environments requiring both speed and accuracy. It features a unique 96-well Fast block that accommodates reaction volumes from 5 to 30 uL, but is optimized for 10 uL, ensuring consistent thermal uniformity across all samples.\n\t\u003cbr\u003e\u003cbr\u003e\n\tThe system's rapid ramp rates accelerate the processing times to deliver results in less than 30 minutes without compromising the extension times or the quality of the assay. This efficiency is matched by the system’s robust temperature controls, maintaining a uniformity of ± 0.5°C and an accuracy of ± 0.25°C, which are crucial for precise thermal cycling. Additionally, the optical system uses a CCD camera coupled with a halogen lamp for excitation, along with five excitation and emission filters, enabling sensitive multiplex detection of up to five targets per well.\n\t\u003cbr\u003e\u003cbr\u003e\n\tWith a dynamic range extending over nine logs, the 7500 Fast can detect as little as one copy of a template in a 20 uL reaction with 99.7% confidence. This system is not only a testament to Applied Biosystems' legacy of quality and innovation but also an essential tool for modern laboratories focused on genetic analysis and molecular diagnostics. \u003cb\u003ePlease Note: We recommend performing a Dye Calibration for the Dye you plan on using for your application(s). Please refer to the Operator's Manual for instructions.\u003c\/b\u003e\n\t\u003cbr\u003e\u003cbr\u003eAll of our equipment is fully tested to perform at factory specifications before being shipped.\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"included-box\"\u003e\n\t\t\u003cspan class=\"included-header\"\u003eINCLUDED:\u003c\/span\u003e\u003cbr\u003eThe Applied Biosystems 7500 Fast Real-Time PCR System includes:\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003e96-Well Fast Block\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eNew Halogen Lamp\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eBackground Calibration Report\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eROI Calibration Report\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eOptical Calibration Report\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eWindows 11 Professional 64-Bit Data Station\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eApplied Biosystems 7500 Software Installed\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003ePower Cord\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eOperator's Manual\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eFull 180 Day Parts and Labor Warranty\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\n\t\u003ch2\u003eApplied Biosystems 7500 Fast Real-Time PCR System Specifications\u003c\/h2\u003e\n\t\u003ctable\u003e\n\t\u003ctbody\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tBlock Configuration\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t96-Well Fast (5 to 30 uL reactions, optimized for 10 uL reactions)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tTemperature Range\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t4°C to 100°C\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tTemperature Uniformity\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t± 0.5°C (30 seconds after clock start)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tTemperature Accuracy\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t± 0.25°C of setpoint\/display temperature (measured at 3 minutes after clock start)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tMaximum Ramp Rate\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t5.5°C\/second\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tRun Time\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u0026lt; 30 minutes\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tOptical System\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tCCD camera with halogen lamp excitation; five-exciation and five-emission filters\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDynamic Range\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t9 logs of linear dynamic range\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tSensitivity\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tDetection of 1 copy of template in 20 uL reaction for a single reporter TaqMan assay, with 99.7% confidence\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tMultiplexing\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tUp to 5 targets per well\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDye Compatibility\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tFAM\/SYBR Green, VIC\/JOE, NED\/TAMRA\/Cy3, ROX\/Texas Red, and Cy5 (Calibration for new dyes within the wavelength range is possible by following the custom dye calibration procedure in the user’s manual)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tPassive Reference Dyes\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tROX dye or any calibrated dye\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDimensions (W x D x H)\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t13.9 x 17.7 x 19.3 in. (34 x 45 x 49 cm)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tWeight\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t75 lb. (34 kg)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tElectrical Requirements\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t100-240V, 50\/60Hz, 1080W\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\t\u003c\/table\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003ctable\u003e\n\t\u003ctbody\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd colspan=\"2\"\u003e\n\t\t\t\u003ccenter\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t\tComputer Specifications\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003c\/center\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\tProcessor\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\tIntel Core I5-8350U CPU\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\tRAM\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t16.0 GB\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\tHard Drive\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\t512GB Internal SSD\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\tOperating System\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\tWindows 11 Professional, 64-bit\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\t\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cspan class=\"downloads-header\"\u003eDownloads\u003c\/span\u003e\n\u003cdiv class=\"downloads-section\"\u003e\n\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Applied_Biosystems_7500_Real-Time_PCR_System_-_Marshall_Scientific.pdf?v=1779986115\" target=\"blank\"\u003e\n\t\tTechnical Specification Download\n\t\t\u003c\/a\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Applied_Biosystems_7500_Fast_Real-Time_PCR_System_Manual_-_Marshall_Scientific.pdf?v=1779986120\" target=\"blank\"\u003e\n\t\tOperator's Manual Download\n\t\t\u003c\/a\u003e\n\t\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"formalquote2\"\u003e\n\t\u003ca class=\"formalquote2link\" href=\"\/formal_quote_a\/2882.htm\" target=\"blank\"\u003eRequest a Formal Quote\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cspan class=\"windows11\"\u003e\u003c\/span\u003e","brand":"My Store","offers":[{"title":"Default Title","offer_id":42474431053914,"sku":"AB-7500F","price":8995.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AB-7500F-2.jpg?v=1761203774"},{"product_id":"applied-biosystems-quantstudio-12k-flex-real-time-pcr-system-w-96-well-fast-sample-block","title":"Applied Biosystems QuantStudio 12K Flex Real-Time PCR System w\/ 96-Well Fast Sample Block","description":"\u003cdiv class=\"productdescriptiontables\"\u003e\n\t\u003ch1\u003eApplied Biosystems QuantStudio 12K Flex Real-Time PCR System w\/ 96-Well Fast Sample Block\u003c\/h1\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-section\"\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eBlock Configuration\u003c\/b\u003e\u003cbr\u003e96-Well Fast (15 to 30 uL reactions)\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eMaximum Ramp Rate\u003c\/b\u003e\u003cbr\u003e3.0°C\/second\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eWell-to-Well Variability\u003c\/b\u003e\u003cbr\u003e± 0.25°C\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"features-section\"\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cspan class=\"features-header\"\u003eFeatures\u003c\/span\u003e\n\t\t\t\u003cul\u003e\n\t\t\t\t\u003cli\u003eProcesses up to 110,000 data points in an 8-hour day with minimal hands-on time\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eFive interchangeable block formats for maximum workflow flexibility\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eCompatible with automation systems like the Thermo Scientific Orbitor RS2 Microplate Mover\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eEnhanced OptiFlex system enables multiplex detection of up to six targets\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eSupports 21 CFR Part 11 compliance with integrated security and audit features\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eRapid block changes in under one minute without the need for tools\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eHigh sensitivity detection down to a single copy with a dynamic range of nine logarithmic units\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eIdeal for diverse applications such as drug discovery, pharmacogenomics, and agricultural testing\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eDigital PCR capability for precise detection of rare genetic targets\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eStreamlined workflow with just 20 minutes of hands-on time per run\u003c\/li\u003e\n\t\t\t\u003c\/ul\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AB-QS12KF_1fe43c8f-2808-4bcd-9252-e42f9b7c445d.jpg?v=1779986147\"\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003eThe Applied Biosystems QuantStudio 12K Flex Real-Time PCR System w\/ 96-Well Fast Sample Block is a high-throughput, versatile platform designed to meet diverse laboratory needs in gene expression, genotyping, and various PCR applications. This system offers unmatched scalability and efficiency, capable of processing up to four 3,072-reaction OpenArray plates in approximately four hours, producing up to 110,000 data points within an eight-hour workday when paired with the QuantStudio 12K Flex OpenArray AccuFill System. With just 20 minutes of hands-on time per run, it maximizes productivity while minimizing labor.\n\t\u003cbr\u003e\u003cbr\u003e\n\tEngineered for flexibility, the QuantStudio 12K Flex features five interchangeable block formats - OpenArray plate, TaqMan Array Card, 384-well, and both 0.1 mL and 0.2 mL 96-well blocks - allowing seamless transitions between workflows without the need for tools. The instrument supports high-throughput environments with laboratory information management system (LIMS) compatibility and built-in features that facilitate 21 CFR Part 11 compliance, including integrated sample tracking, security, auditing, and electronic signature (SAE) modules for enhanced data integrity and quality control.\n\t\u003cbr\u003e\u003cbr\u003e\n\tAdvanced OptiFlex technology with six independent excitation and emission filter channels enables superior fluorescence detection and multiplexing, supporting up to six targets per reaction. This adaptability makes the system ideal for applications such as drug discovery, pharmacogenomics research, microRNA profiling, agricultural molecular testing, CFTR mutation analysis, and vaginal microbiota studies. The QuantStudio 12K Flex system is automation-compatible, integrating seamlessly with the Thermo Scientific Orbitor RS2 Microplate Mover to streamline workflows and reduce manual handling. It also supports digital PCR with QuantStudio digital PCR kits and DigitalSuite Software, enabling precise detection of rare targets, including cancer mutations and viruses.\n\t\u003cbr\u003e\u003cbr\u003e\n\tBuilt for speed and accuracy, the system offers a maximum block ramp rate of 3.0°C\/second, well-to-well temperature variability of ± 0.25°C, and demonstrated sensitivity down to a single copy. The enhanced OptiFlex system utilizes a white LED excitation source and decoupled detection channels for high-resolution results with dynamic range spanning nine logarithmic units and singleplex resolution as low as a 1.5-fold change. Designed for both current and future research demands, the QuantStudio 12K Flex Real-Time PCR System delivers unparalleled throughput, flexibility, and precision - empowering laboratories to expand the boundaries of their research with confidence. \u003cb\u003ePlease Note: We recommend performing a Dye Calibration for the Dye you plan on using for your application(s). Please refer to the Operator's Manual for instructions.\u003c\/b\u003e\n\t\u003cbr\u003e\u003cbr\u003eAll of our equipment is fully tested to perform at factory specifications before being shipped.\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"included-box\"\u003e\n\t\t\u003cspan class=\"included-header\"\u003eINCLUDED:\u003c\/span\u003e\u003cbr\u003eThe Applied Biosystems QuantStudio 12K Flex Real-Time PCR System w\/ 96-Well Fast Sample Block includes:\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003e96-Well Fast Block\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003e96-Well Fast Heated Cover\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eBackground Calibration Report\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eROI Calibration Report\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eUniformity Calibration Report\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eWindows 11 Professional 64-Bit Data Station with Flatscreen Monitor\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eQuantStudio 12K Flex Software Installed\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003ePower Cord\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eOperator's Manual\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eFull 180 Day Parts and Labor Warranty\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\n\t\u003ch2\u003eApplied Biosystems QuantStudio 12K Flex Real-Time PCR System w\/ 96-Well Fast Sample Block Specifications\u003c\/h2\u003e\n\t\u003ctable\u003e\n\t\u003ctbody\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tBlock Configuration\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t96-Well Fast (15 to 30 uL reactions)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tBlock Change Design\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tBlock change from front in less than 1 minute; no tools required\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tMaximum Block Ramp Rate\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t3.0°C\/second\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tWell-to-Well Variability\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t± 0.25°C\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tRun Time\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t30 minutes expected (96-Well Fast block)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tExcitation Source\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tEnhanced OptiFlex system, white LED\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDetection Channels\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tDecoupled: 6 emission, 6 excitation\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDemonstrated Sensitivity\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tTo 1 copy\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDynamic Range\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tTo 9 logarithmic units\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tResolution\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tAs low as 1.5-fold change for singleplex reaction\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tRemote Monitoring\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tAvailable to monitor up to 15 networked instruments simultaneously\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDimensions (H x W x D)\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t29.1 x 19.7 x 26 in. (73.8 x 50.1 x 66.1 cm)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tWeight\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t154.3 lb. (70 kg)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tElectrical Requirements\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t100-240V, 50\/60Hz, 12.5A\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\t\u003c\/table\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003ctable\u003e\n\t\u003ctbody\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd colspan=\"2\"\u003e\n\t\t\t\u003ccenter\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t\tComputer Specifications\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003c\/center\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\tProcessor\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\tIntel Core I5-8500 CPU\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\tRAM\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\t32.0 GB\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\tHard Drive\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\t500GB Internal SSD\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\tOperating System\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\tWindows 11 Professional, 64-bit\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\t\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cspan class=\"downloads-header\"\u003eDownloads\u003c\/span\u003e\n\u003cdiv class=\"downloads-section\"\u003e\n\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Applied_Biosystems_QuantStudio_12K_Flex_Real-Time_PCR_System_-_Marshall_Scientific.pdf?v=1779986136\" target=\"blank\"\u003e\n\t\tTechnical Specification Download\n\t\t\u003c\/a\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Applied_Biosystems_QuantStudio_12K_Flex_Real-Time_PCR_System_Manual_-_Marshall_Scientific.pdf?v=1779986155\" target=\"blank\"\u003e\n\t\tOperator's Manual Download\n\t\t\u003c\/a\u003e\n\t\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"formalquote2\"\u003e\n\t\u003ca class=\"formalquote2link\" href=\"\/formal_quote_a\/2862.htm\" target=\"blank\"\u003eRequest a Formal Quote\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cspan class=\"windows11\"\u003e\u003c\/span\u003e\n\n\u003cstyle\u003e\n .fpt-container {\n  width: 50%;\n }\n .fpt-box {\n   width: 45%;\n }\n\u003c\/style\u003e","brand":"My Store","offers":[{"title":"Default Title","offer_id":42474434068570,"sku":"AB-QS12KF","price":19995.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AB-QS12KF-2.jpg?v=1761203961"},{"product_id":"applied-biosystems-quantstudio-5-real-time-pcr-system-w-384-well-sample-block","title":"Applied Biosystems QuantStudio 5 Real-Time PCR System w\/ 384-Well Sample Block","description":"\u003cdiv class=\"productdescriptiontables\"\u003e\n\t\u003ch1\u003eApplied Biosystems QuantStudio 5 Real-Time PCR System w\/ 384-Well Sample Block\u003c\/h1\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-section\"\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eBlock Configuration\u003c\/b\u003e\u003cbr\u003e384-Well (5 to 20 uL reactions)\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eMaximum Ramp Rate\u003c\/b\u003e\u003cbr\u003e6.0°C\/second\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eTemperature Uniformity\u003c\/b\u003e\u003cbr\u003e± 0.4°C\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"features-section\"\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cspan class=\"features-header\"\u003eFeatures\u003c\/span\u003e\n\t\t\t\u003cul\u003e\n\t\t\t\t\u003cli\u003eAverage sample ramp rate of 2.92°C\/second for efficient operations\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eEquipped with bright white LED and five coupled filters for a broad range of detection (450 to 650 nm excitation and 500 to 700 nm detection)\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eAllows multiplexing of up to five targets, enhancing assay capability\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eDynamic range over 10 logarithmic units for excellent sensitivity and precision\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eOnboard memory capacity of 10 GB, storing between 2,000 to 5,000 run files\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eDesktop and web-based software supports 21 CFR Part 11 compliance for security and e-signature\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eIntegrated with Connect cloud-based platform for remote data access and management\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eDesigned for quick installation and immediate use, facilitating seamless integration into lab workflows\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eFeatures pre-optimized protocol templates to minimize training requirements for new users\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eOffers locked workflow options to ensure experimental consistency across runs\u003c\/li\u003e\n\t\t\t\u003c\/ul\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AB-QS5384_4c2e7456-ab57-48a4-b811-fa9f317db57d.jpg?v=1779986159\"\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003eThe Applied Biosystems QuantStudio 5 Real-Time PCR System w\/ 384-Well Sample Block offers high-performance, adaptable configurations suitable for any laboratory setting. It supports sample reactions ranging from 5 to 20 µL and achieves rapid thermal cycling with a maximum ramp rate of 6.0°C\/second, along with an average sample ramp rate of 2.92°C\/second. The system ensures precise temperature uniformity (± 0.4°C), essential for consistent results. Featuring a bright white LED excitation source and five coupled filters, the QuantStudio 5 spans an excitation range of 450 to 650 nm and a detection range of 500 to 700 nm, enabling efficient multiplexing of up to five targets simultaneously.\n\t\u003cbr\u003e\u003cbr\u003e\n\tWith a dynamic range that extends over 10 logarithmic units, this system is capable of detecting subtle differences as small as 1.5-fold in target quantities in singleplex reactions, offering superior sensitivity and resolution. The onboard memory supports up to 10 GB, accommodating between 2,000 to 5,000 run files, which simplifies data management and accessibility.\n\t\u003cbr\u003e\u003cbr\u003e\n\tThis system also features comprehensive software that includes desktop and web-based analysis options. The software supports critical security measures, including auditing, e-signature capabilities, and compliance with 21 CFR Part 11, ensuring that your experimental data and run information are securely managed. Additionally, the QuantStudio 5 integrates seamlessly with the Connect cloud-based platform, allowing for remote data access and management anytime and anywhere, enhancing the convenience and efficiency of your research operations. \u003cb\u003ePlease Note: We recommend performing a Dye Calibration for the Dye you plan on using for your application(s). Please refer to the Operator's Manual for instructions.\u003c\/b\u003e\n\t\u003cbr\u003e\u003cbr\u003eAll of our equipment is fully tested to perform at factory specifications before being shipped.\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"included-box\"\u003e\n\t\t\u003cspan class=\"included-header\"\u003eINCLUDED:\u003c\/span\u003e\u003cbr\u003eThe Applied Biosystems QuantStudio 5 Real-Time PCR System w\/ 384-Well Sample Block includes:\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003e384-Well Block\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eBackground Calibration Report\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eROI Calibration Report\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eUniformity Calibration Report\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eWindows 11 Professional 64-Bit Data Station\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eQuantStudio Design \u0026amp; Analysis Desktop Software Installed\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003ePower Cord\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eOperator's Manual\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eFull 180 Day Parts and Labor Warranty\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\n\t\u003ch2\u003eApplied Biosystems QuantStudio 5 Real-Time PCR System w\/ 384-Well Sample Block Specifications\u003c\/h2\u003e\n\t\u003ctable\u003e\n\t\u003ctbody\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tBlock Configuration\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t384-Well (5 to 20 uL reactions)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tMaximum Ramp Rate\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t6.0°C\/second\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tAverage Sample Ramp Rate\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t2.92°C\/second\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tTemperature Uniformity\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t± 0.4°C\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tRun Time\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tLess than 30 minutes\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tHeating and Cooling Method\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tPeltier\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tExcitation (Light Source)\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tBright white LED\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tFilters or Colors\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t5 coupled filters\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tExcitation and Detection Range\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t450 to 650 nm and 500 to 700 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tMultiplexing\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tUp to 5 targets\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDynamic Range\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t10 logarithmic units\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tSensitivity (Resolution)\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tDetect differences as small as 1.5-fold in target quantities in a singleplex reaction\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tData Acquisition\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tWhole-plate imaging\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tOnboard Memory\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t10 GB, which translates to approximately 2,000 to 5,000 run files\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDye Compatibility\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tFAM™\/SYBR™ Green, VIC™\/JOE™\/HEX™\/TET™, ABY™\/NED™\/TAMRA™\/Cy®3, JUN™, ROX™\/Texas Red™, Mustang Purple™, Cy®5\/LIZ™, Cy®5.5\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDimensions (W x D x H)\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t10.6 x 19.7 x 15.7 in. (27 x 50 x 40 cm)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tWeight\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t57.3 lb. (26 kg)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tElectrical Requirements\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t100-240V, 50\/60Hz\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\t\u003c\/table\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003ctable\u003e\n\t\u003ctbody\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd colspan=\"2\"\u003e\n\t\t\t\u003ccenter\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t\tComputer Specifications\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003c\/center\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\tProcessor\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\tIntel Core I5-8350U CPU\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\tRAM\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t16.0 GB\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\tHard Drive\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\t512GB Internal SSD\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\tOperating System\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\tWindows 11 Professional, 64-bit\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\t\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cspan class=\"downloads-header\"\u003eDownloads\u003c\/span\u003e\n\u003cdiv class=\"downloads-section\"\u003e\n\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Applied_Biosystems_QuantStudio_5_Real-Time_PCR_System_w_384-Well_Sample_Block_-_Marshall_Scientific.pdf?v=1779986171\" target=\"blank\"\u003e\n\t\tTechnical Specification Download\n\t\t\u003c\/a\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Applied_Biosystems_QuantStudio_5_Real-Time_PCR_System_w_384-Well_Sample_Block_Manual_-_Marshall_Scientific.pdf?v=1779986176\" target=\"blank\"\u003e\n\t\tOperator's Manual Download\n\t\t\u003c\/a\u003e\n\t\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"formalquote2\"\u003e\n\t\u003ca class=\"formalquote2link\" href=\"\/formal_quote_a\/2879.htm\" target=\"blank\"\u003eRequest a Formal Quote\u003c\/a\u003e\n\u003c\/div\u003e\n\n\u003cstyle\u003e\n.fpt-container {\n  width: 50%;\n}\n.fpt-box {\n   width: 45%;\n}\na.fpt-button {\n  margin-top: 28px;\n}\n\u003c\/style\u003e\n\u003cspan class=\"windows11\"\u003e\u003c\/span\u003e","brand":"My Store","offers":[{"title":"Default Title","offer_id":42474434396250,"sku":"AB-QS5384","price":13995.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AB-QS5384-2.jpg?v=1761203997"},{"product_id":"applied-biosystems-quantstudio-5-real-time-pcr-system-w-96-well-sample-block","title":"Applied Biosystems QuantStudio 5 Real-Time PCR System w\/ 96-Well Sample Block","description":"\u003cdiv class=\"productdescriptiontables\"\u003e\n\t\u003ch1\u003eApplied Biosystems QuantStudio 5 Real-Time PCR System w\/ 96-Well Sample Block\u003c\/h1\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-section\"\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eBlock Configuration\u003c\/b\u003e\u003cbr\u003e96-Well (10 to 100 uL reactions)\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eMaximum Ramp Rate\u003c\/b\u003e\u003cbr\u003e6.5°C\/second\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eTemperature Uniformity\u003c\/b\u003e\u003cbr\u003e± 0.4°C\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"features-section\"\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cspan class=\"features-header\"\u003eFeatures\u003c\/span\u003e\n\t\t\t\u003cul\u003e\n\t\t\t\t\u003cli\u003eSix decoupled optical channels with 21 filter combinations support precise multiplex detection\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eVeriFlex technology enables independent temperature control across six zones for flexible assay development\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eBright white LED ensures consistent excitation for reliable fluorescence detection\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eOptical scanning system delivers accurate, high-sensitivity results across diverse fluorophores\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eTouchscreen interface with intuitive navigation simplifies setup and run monitoring\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eCloud connectivity enables secure remote data access, storage, and collaboration\u003c\/li\u003e\n\t\t\t\t\u003cli\u003ePreprogrammed protocol templates streamline workflow for common real-time PCR applications\u003c\/li\u003e\n\t\t\t\u003c\/ul\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AB-QS5384_4c2e7456-ab57-48a4-b811-fa9f317db57d.jpg?v=1779986159\"\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003eThe Applied Biosystems QuantStudio 5 Real-Time PCR System w\/ 96-Well Sample Block is designed to deliver high-performance results for a wide range of molecular biology applications. With six independently controlled temperature zones through VeriFlex technology, it allows for precise thermal cycling and flexible assay development. The system supports up to six-target multiplexing with 21 filter combinations and decoupled optical channels—making it ideal for complex gene expression studies and SNP genotyping.\n\t\u003cbr\u003e\u003cbr\u003e\n\tA bright white LED provides consistent excitation, while whole-plate imaging captures accurate and reproducible data without mechanical scanning. Its intuitive touchscreen interface enables real-time monitoring and simplified program setup, and the system integrates with a cloud-based platform for secure data access and collaboration. With fast ramp rates, preoptimized protocol templates, and 21 CFR Part 11–ready software features including auditing and e-signatures, the QuantStudio 5 streamlines workflows without sacrificing precision or traceability. \u003cb\u003ePlease Note: We recommend performing a Dye Calibration for the Dye you plan on using for your application(s). Please refer to the Operator's Manual for instructions.\u003c\/b\u003e\n\t\u003cbr\u003e\u003cbr\u003eAll of our equipment is fully tested to perform at factory specifications before being shipped.\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"included-box\"\u003e\n\t\t\u003cspan class=\"included-header\"\u003eINCLUDED:\u003c\/span\u003e\u003cbr\u003eThe Applied Biosystems QuantStudio 5 Real-Time PCR System w\/ 96-Well Sample Block includes:\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003e0.2ml 96-Well Block\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eBackground Calibration Report\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eROI Calibration Report\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eUniformity Calibration Report\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eWindows 11 Professional 64-Bit Data Station\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eQuantStudio Design \u0026amp; Analysis Desktop Software Installed\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003ePower Cord\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eOperator's Manual\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eFull 180 Day Parts and Labor Warranty\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\n\t\u003ch2\u003eApplied Biosystems QuantStudio 5 Real-Time PCR System w\/ 96-Well Sample Block Specifications\u003c\/h2\u003e\n\t\u003ctable\u003e\n\t\u003ctbody\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tBlock Configuration\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t96-Well (10 to 100 uL reactions)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tMaximum Ramp Rate\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t6.5°C\/second\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tAverage Sample Ramp Rate\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t3.66°C\/second\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tTemperature Uniformity\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t± 0.4°C\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tRun Time\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tLess than 30 minutes\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tHeating and Cooling Method\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tPeltier\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tExcitation (Light Source)\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tBright white LED\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tFilters or Colors\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t6 decoupled filters\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tExcitation and Detection Range\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t450 to 680 nm and 500 to 730 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tMultiplexing\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tUp to 6 targets\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDynamic Range\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t10 logarithmic units\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tSensitivity (Resolution)\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tDetect differences as small as 1.5-fold in target quantities in a singleplex reaction\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tData Acquisition\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tWhole-plate imaging\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tOnboard Memory\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t10 GB, which translates to approximately 2,000 to 5,000 run files\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDye Compatibility\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tFAM™\/SYBR™ Green, VIC™\/JOE™\/HEX™\/TET™, ABY™\/NED™\/TAMRA™\/Cy®3, JUN™, ROX™\/Texas Red™, Mustang Purple™, Cy®5\/LIZ™, Cy®5.5\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDimensions (W x D x H)\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t10.6 x 19.7 x 15.7 in. (27 x 50 x 40 cm)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tWeight\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t57.3 lb. (26 kg)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tElectrical Requirements\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t100-240V, 50\/60Hz\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\t\u003c\/table\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003ctable\u003e\n\t\u003ctbody\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd colspan=\"2\"\u003e\n\t\t\t\u003ccenter\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t\tComputer Specifications\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003c\/center\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\tProcessor\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\tIntel Core I5-8350U CPU\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\tRAM\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t16.0 GB\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\tHard Drive\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\t512GB Internal SSD\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\tOperating System\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\tWindows 11 Professional, 64-bit\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\t\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cspan class=\"downloads-header\"\u003eDownloads\u003c\/span\u003e\n\u003cdiv class=\"downloads-section\"\u003e\n\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Applied_Biosystems_QuantStudio_5_Real-Time_PCR_System_w_96-Well_Sample_Block_-_Marshall_Scientific.pdf?v=1779986182\" target=\"blank\"\u003e\n\t\tTechnical Specification Download\n\t\t\u003c\/a\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Applied_Biosystems_QuantStudio_5_Real-Time_PCR_System_w_96-Well_Sample_Block_Manual_-_Marshall_Scientific.pdf?v=1779986186\" target=\"blank\"\u003e\n\t\tOperator's Manual Download\n\t\t\u003c\/a\u003e\n\t\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"formalquote2\"\u003e\n\t\u003ca class=\"formalquote2link\" href=\"\/formal_quote_a\/2941.htm\" target=\"blank\"\u003eRequest a Formal Quote\u003c\/a\u003e\n\u003c\/div\u003e\n\n\u003cstyle\u003e\n.fpt-container {\n  width: 50%;\n}\n.fpt-box {\n   width: 45%;\n}\na.fpt-button {\n  margin-top: 28px;\n}\n\u003c\/style\u003e\n\u003cspan class=\"windows11\"\u003e\u003c\/span\u003e","brand":"My Store","offers":[{"title":"Default Title","offer_id":42474434789466,"sku":"AB-QS596","price":14995.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AB-QS596-2.jpg?v=1761204029"},{"product_id":"applied-biosystems-quantstudio-7-flex-real-time-pcr-system-w-384-well-sample-block","title":"Applied Biosystems QuantStudio 7 Flex Real-Time PCR System w\/ 384-Well Sample Block","description":"\u003cdiv class=\"productdescriptiontables\"\u003e\n\t\u003ch1\u003eApplied Biosystems QuantStudio 7 Flex Real-Time PCR System w\/ 384-Well Sample Block\u003c\/h1\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-section\"\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eRamp-Up Rate\u003c\/b\u003e\u003cbr\u003e3.5°C\/second\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eRamp-Down Rate\u003c\/b\u003e\u003cbr\u003e3.0°C\/second\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eWell-to-Well Variability\u003c\/b\u003e\u003cbr\u003e± 0.25°C\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"features-section\"\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cspan class=\"features-header\"\u003eFeatures\u003c\/span\u003e\n\t\t\t\u003cul\u003e\n\t\t\t\t\u003cli\u003eAdvanced multiplexing capabilities with interchangeable block formats for diverse applications\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eAccommodates four different block types including 96-well, 96-well Fast, 384-well, and TaqMan Array Card (384-well block included)\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eCompatible with over 8 million TaqMan assays for comprehensive experimental flexibility\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eSimplified workflow with intuitive software and touch-screen interface\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eTool-free block exchange enhances ease of use and operational efficiency\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eOptiFlex system features six decoupled excitation and emission filter channels with 21 filter combinations\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eDetects changes in target quantity as small as 1.5-fold in single-plex reactions\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eOffers a linear dynamic range of 10 logs for precise quantification\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eDesigned for high throughput with automation capabilities for streamlined processing\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eSupports a wide range of applications, including gene expression, SNP genotyping, and protein thermal shift experiments\u003c\/li\u003e\n\t\t\t\u003c\/ul\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AB-QS7F2_65de61c0-9df8-4555-9997-6cb4d8d6fbf2.jpg?v=1779986190\"\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003eThe Applied Biosystems QuantStudio 7 Flex Real-Time PCR System w\/ 384-Well Sample Block represents a significant advancement in PCR technology, offering extensive multiplexing capabilities and interchangeable block formats to support a wide array of real-time PCR applications. This system is designed to enhance research flexibility and precision, accommodating four different block types: 96-well, 96-well Fast, 384-well, and TaqMan Array Card blocks. The inclusion of over 8 million compatible TaqMan assays for diverse experiments, such as gene expression and protein expression, underscores its application versatility. Moreover, the system's intuitive touch-screen interface, combined with automation-friendly features and tool-free block exchange, simplifies workflows and promotes efficiency in the laboratory setting.\n\t\u003cbr\u003e\u003cbr\u003e\n\tKey to the QuantStudio 7 Flex system's reliability are its advanced optical and thermal components, which ensure minimal variability both within and across instruments. The OptiFlex system, which consists of six independent excitation and emission filter channels with 21 filter combinations, allows for high flexibility in multiplexing and chemical reactions. This system is particularly effective in detecting subtle changes in target quantity, achieving a linear dynamic range over ten logs and facilitating sensitive data analysis in single-plex reactions.\n\t\u003cbr\u003e\u003cbr\u003e\n\tFor laboratories aiming to streamline their processes and increase throughput, the QuantStudio 7 Flex system is an ideal solution. It supports a variety of applications from gene regulation studies to protein thermal shift assays. Its high ramp-up and ramp-down rates of 3.5°C\/second and 3.0°C\/second respectively, along with low well-to-well variability (± 0.25°C), ensure rapid and consistent performance. Additionally, the system is designed for easy integration with robotics for automated setups, making it a powerful tool for high-throughput environments where precision and reliability are paramount. \u003cb\u003ePlease Note: We recommend performing a Dye Calibration for the Dye you plan on using for your application(s). Please refer to the Operator's Manual for instructions.\u003c\/b\u003e\n\t\u003cbr\u003e\u003cbr\u003eAll of our equipment is fully tested to perform at factory specifications before being shipped.\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"included-box\"\u003e\n\t\t\u003cspan class=\"included-header\"\u003eINCLUDED:\u003c\/span\u003e\u003cbr\u003eThe Applied Biosystems QuantStudio 7 Flex Real-Time PCR System w\/ 384-Well Sample Block includes:\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003e384-Well Block\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003e384-Well Heated Cover\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eNew Lamp\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eBackground Calibration Report\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eROI Calibration Report\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eUniformity Calibration Report\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eWindows 11 Professional 64-Bit Data Station with Flatscreen Monitor\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eQuantStudio Real-Time PCR Software Version 1.7.2 Installed\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003ePower Cord\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eOperator's Manual\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eFull 180 Day Parts and Labor Warranty\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\n\t\u003ch2\u003eApplied Biosystems QuantStudio 7 Flex Real-Time PCR System w\/ 384-Well Sample Block Specifications\u003c\/h2\u003e\n\t\u003ctable\u003e\n\t\u003ctbody\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tBlock Configuration\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t384-well\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tBlock Change Design\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tBlock change from front in less than 1 minute; no tools required\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tRamp-Up Rate\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t3.5°C\/second\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tRamp-Down Rate\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t3.0°C\/second\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tWell-to-Well Variability\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t± 0.25°C\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tExcitation Source\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tOptiFlex system lamp\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDetection Channels\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tExcitation: 455 to 672 nm\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tEmission: 505 to 723 nm\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDimensions (H x W x D)\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t29.1 x 19.7 x 26 in. (73.8 x 50.1 x 66.1 cm)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tWeight\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t154.3 lb. (70 kg)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tElectrical Requirements\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t100-240V, 50\/60Hz, 12.5A\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\t\u003c\/table\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003ctable\u003e\n\t\u003ctbody\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd colspan=\"2\"\u003e\n\t\t\t\u003ccenter\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t\tComputer Specifications\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003c\/center\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\tProcessor\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\tIntel Core I5-8500 CPU\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\tRAM\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\t32.0 GB\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\tHard Drive\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\t500GB Internal SSD\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\tOperating System\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\tWindows 11 Professional, 64-bit\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\t\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cspan class=\"downloads-header\"\u003eDownloads\u003c\/span\u003e\n\u003cdiv class=\"downloads-section\"\u003e\n\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Applied_Biosystems_QuantStudio_7_Flex_Real-Time_PCR_System_-_Marshall_Scientific.pdf?v=1779986206\" target=\"blank\"\u003e\n\t\tTechnical Specification Download\n\t\t\u003c\/a\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Applied_Biosystems_QuantStudio_7_Flex_Real-Time_PCR_System_Manual_-_Marshall_Scientific.pdf?v=1779986210\" target=\"blank\"\u003e\n\t\tOperator's Manual Download\n\t\t\u003c\/a\u003e\n\t\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"formalquote2\"\u003e\n\t\u003ca class=\"formalquote2link\" href=\"\/formal_quote_a\/2834.htm\" target=\"blank\"\u003eRequest a Formal Quote\u003c\/a\u003e\n\u003c\/div\u003e\n\n\u003cstyle\u003e\n.fpt-container {\n  width: 50%;\n}\n.fpt-box {\n   width: 45%;\n}\na.fpt-button {\n  margin-top: 28px;\n}\n.fpt-box p {\n   height: 49px;\n}\n\u003c\/style\u003e\n\u003cspan class=\"windows11\"\u003e\u003c\/span\u003e","brand":"My Store","offers":[{"title":"Default Title","offer_id":42474436591706,"sku":"AB-QS7F","price":16495.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AB-QS7F-2.jpg?v=1761204069"},{"product_id":"applied-biosystems-quantstudio-7-flex-real-time-pcr-system-w-96-well-fast-sample-block","title":"Applied Biosystems QuantStudio 7 Flex Real-Time PCR System w\/ 96-Well Fast Sample Block","description":"\u003cdiv class=\"productdescriptiontables\"\u003e\n\t\u003ch1\u003eApplied Biosystems QuantStudio 7 Flex Real-Time PCR System w\/ 96-Well Fast Sample Block\u003c\/h1\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-section\"\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eRamp-Up Rate\u003c\/b\u003e\u003cbr\u003e6.5°C\/second\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eRamp-Down Rate\u003c\/b\u003e\u003cbr\u003e6.0°C\/second\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eWell-to-Well Variability\u003c\/b\u003e\u003cbr\u003e± 0.25°C\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"features-section\"\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cspan class=\"features-header\"\u003eFeatures\u003c\/span\u003e\n\t\t\t\u003cul\u003e\n\t\t\t\t\u003cli\u003eAdvanced multiplexing capabilities with interchangeable block formats for diverse applications\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eAccommodates four different block types including 96-well, 96-well Fast, 384-well, and TaqMan Array Card (96-well Fast block included)\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eCompatible with over 8 million TaqMan assays for comprehensive experimental flexibility\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eSimplified workflow with intuitive software and touch-screen interface\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eTool-free block exchange enhances ease of use and operational efficiency\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eOptiFlex system features six decoupled excitation and emission filter channels with 21 filter combinations\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eDetects changes in target quantity as small as 1.5-fold in single-plex reactions\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eOffers a linear dynamic range of 10 logs for precise quantification\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eDesigned for high throughput with automation capabilities for streamlined processing\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eSupports a wide range of applications, including gene expression, SNP genotyping, and protein thermal shift experiments\u003c\/li\u003e\n\t\t\t\u003c\/ul\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AB-QS7F2_65de61c0-9df8-4555-9997-6cb4d8d6fbf2.jpg?v=1779986190\"\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003eThe Applied Biosystems QuantStudio 7 Flex Real-Time PCR System w\/ 96-Well Fast Sample Block represents a significant advancement in PCR technology, offering extensive multiplexing capabilities and interchangeable block formats to support a wide array of real-time PCR applications. This system is designed to enhance research flexibility and precision, accommodating four different block types: 96-well, 96-well Fast, 384-well, and TaqMan Array Card blocks. The inclusion of over 8 million compatible TaqMan assays for diverse experiments, such as gene expression and protein expression, underscores its application versatility. Moreover, the system's intuitive touch-screen interface, combined with automation-friendly features and tool-free block exchange, simplifies workflows and promotes efficiency in the laboratory setting.\n\t\u003cbr\u003e\u003cbr\u003e\n\tKey to the QuantStudio 7 Flex system's reliability are its advanced optical and thermal components, which ensure minimal variability both within and across instruments. The OptiFlex system, which consists of six independent excitation and emission filter channels with 21 filter combinations, allows for high flexibility in multiplexing and chemical reactions. This system is particularly effective in detecting subtle changes in target quantity, achieving a linear dynamic range over ten logs and facilitating sensitive data analysis in single-plex reactions.\n\t\u003cbr\u003e\u003cbr\u003e\n\tFor laboratories aiming to streamline their processes and increase throughput, the QuantStudio 7 Flex system is an ideal solution. It supports a variety of applications from gene regulation studies to protein thermal shift assays. Its high ramp-up and ramp-down rates of 6.5°C\/second and 6.0°C\/second respectively, along with low well-to-well variability (± 0.25°C), ensure rapid and consistent performance. Additionally, the system is designed for easy integration with robotics for automated setups, making it a powerful tool for high-throughput environments where precision and reliability are paramount. \u003cb\u003ePlease Note: We recommend performing a Dye Calibration for the Dye you plan on using for your application(s). Please refer to the Operator's Manual for instructions.\u003c\/b\u003e\n\t\u003cbr\u003e\u003cbr\u003eAll of our equipment is fully tested to perform at factory specifications before being shipped.\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"included-box\"\u003e\n\t\t\u003cspan class=\"included-header\"\u003eINCLUDED:\u003c\/span\u003e\u003cbr\u003eThe Applied Biosystems QuantStudio 7 Flex Real-Time PCR System w\/ 96-Well Fast Sample Block Sample Block includes:\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003e96-Well Fast Block\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003e96-Well Fast Heated Cover\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eNew Lamp\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eBackground Calibration Report\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eROI Calibration Report\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eUniformity Calibration Report\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eWindows 11 Professional 64-Bit Data Station with Flatscreen Monitor\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eQuantStudio Real-Time PCR Software Version 1.7.2 Installed\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003ePower Cord\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eOperator's Manual\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eFull 180 Day Parts and Labor Warranty\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\n\t\u003ch2\u003eApplied Biosystems QuantStudio 7 Flex Real-Time PCR System w\/ 96-Well Fast Sample Block Sample Block Specifications\u003c\/h2\u003e\n\t\u003ctable\u003e\n\t\u003ctbody\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tBlock Configuration\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t96-well Fast\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tBlock Change Design\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tBlock change from front in less than 1 minute; no tools required\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tRamp-Up Rate\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t6.5°C\/second\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tRamp-Down Rate\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t6.0°C\/second\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tWell-to-Well Variability\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t± 0.25°C\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tExcitation Source\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tOptiFlex system lamp\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDetection Channels\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tExcitation: 455 to 672 nm\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tEmission: 505 to 723 nm\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDimensions (H x W x D)\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t29.1 x 19.7 x 26 in. (73.8 x 50.1 x 66.1 cm)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tWeight\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t154.3 lb. (70 kg)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tElectrical Requirements\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t100-240V, 50\/60Hz, 12.5A\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\t\u003c\/table\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003ctable\u003e\n\t\u003ctbody\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd colspan=\"2\"\u003e\n\t\t\t\u003ccenter\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t\tComputer Specifications\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003c\/center\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\tProcessor\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\tIntel Core I5-8500 CPU\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\tRAM\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\t32.0 GB\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\tHard Drive\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\t500GB Internal SSD\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\tOperating System\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\tWindows 11 Professional, 64-bit\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\t\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cspan class=\"downloads-header\"\u003eDownloads\u003c\/span\u003e\n\u003cdiv class=\"downloads-section\"\u003e\n\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Applied_Biosystems_QuantStudio_7_Flex_Real-Time_PCR_System_-_Marshall_Scientific.pdf?v=1779986206\" target=\"blank\"\u003e\n\t\tTechnical Specification Download\n\t\t\u003c\/a\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Applied_Biosystems_QuantStudio_7_Flex_Real-Time_PCR_System_Manual_-_Marshall_Scientific.pdf?v=1779986210\" target=\"blank\"\u003e\n\t\tOperator's Manual Download\n\t\t\u003c\/a\u003e\n\t\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"formalquote2\"\u003e\n\t\u003ca class=\"formalquote2link\" href=\"\/formal_quote_a\/2861.htm\" target=\"blank\"\u003eRequest a Formal Quote\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cspan class=\"windows11\"\u003e\u003c\/span\u003e","brand":"My Store","offers":[{"title":"Default Title","offer_id":42474437640282,"sku":"AB-QS7F96F","price":17495.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AB-QS7F96F-2.jpg?v=1761204108"},{"product_id":"applied-biosystems-viia-7-real-time-pcr-system-w-384-well-sample-block","title":"Applied Biosystems ViiA 7 Real-Time PCR System w\/ 384-Well Sample Block","description":"\u003cdiv class=\"productdescriptiontables\"\u003e\n\t\u003ch1\u003eApplied Biosystems ViiA 7 Real-Time PCR System w\/ 384-Well Sample Block\u003c\/h1\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-section\"\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eBlock Configuration\u003c\/b\u003e\u003cbr\u003e384-Well (5 to 20 uL reactions)\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eRun Time\u003c\/b\u003e\u003cbr\u003e~ 35 Minutes\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eExcitation\/Detection Wavelengths\u003c\/b\u003e\u003cbr\u003eEX: 450 to 670 nm \/ EM: 500 to 720 nm (Filter-based)\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"features-section\"\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cspan class=\"features-header\"\u003eFeatures\u003c\/span\u003e\n\t\t\t\u003cul\u003e\n\t\t\t\t\u003cli\u003eOptiFlex system with six excitation and six emission filters for high-resolution detection\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eDetects as little as 1.5-fold changes in singleplex target quantities\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eFront-access block change in under one minute with no tools required\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eIntuitive 7\" touchscreen interface with one-touch protocol setup\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eCompatible with TaqMan Array Micro Fluidic Cards for high-throughput workflows\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eSupports up to nine logs of linear dynamic range and single-copy sensitivity\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eAutomation-ready and integrates with the Twister II Robot for scalable throughput\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eBuilt-in data recovery for over 100 runs ensures workflow continuity\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eFully configurable data export formats for flexible downstream analysis\u003c\/li\u003e\n\t\t\t\u003c\/ul\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AB-VIIA384_64ce3954-0b8d-42b1-b7ef-de29a8e9ec4c.jpg?v=1779986217\"\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003eThe Applied Biosystems ViiA 7 Real-Time PCR System with 384-Well Sample Block is a high-throughput qPCR platform designed to deliver exceptional performance, reliability, and flexibility for demanding research environments. Engineered with a front-access interchangeable block system, it allows for rapid block changes in under one minute without tools or disconnecting peripherals. The 384-well format supports reaction volumes from 5 to 20 µL and enables fast run times of approximately 35 minutes, making it ideal for medium- to high-throughput applications. At the core of the system is the advanced OptiFlex fluorescence detection module, featuring six independent excitation (450 - 670 nm) and six emission (500 - 720 nm) filters, offering unmatched multiplexing capabilities and precise quantification, detecting target changes as small as 1.5-fold in singleplex reactions.\n\t\u003cbr\u003e\u003cbr\u003e\n\tThe ViiA 7 System supports a fully integrated workflow, with compatibility for standard and fast 96-well plates, 384-well plates, as well as TaqMan® Array Micro Fluidic Cards, allowing users to perform hundreds of assays without the need for liquid-handling robotics. A user-friendly 7\" color touchscreen interface, one-touch protocols, and automation readiness via the Twister II Robot (not included) ensure streamlined operation and scalability. Enhanced software tools include customizable export formats, ramp rate detection flexibility, and robust data recovery capabilities for over 100 runs. With a dynamic range extending up to nine logs and the sensitivity to detect down to a single copy, the ViiA 7 delivers high-quality, reproducible results instrument to instrument and run to run, empowering researchers to achieve more, faster. \u003cb\u003ePlease Note: We recommend performing a Dye Calibration for the Dye you plan on using for your application(s). Please refer to the Operator's Manual for instructions.\u003c\/b\u003e\n\t\u003cbr\u003e\u003cbr\u003eAll of our equipment is fully tested to perform at factory specifications before being shipped.\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"included-box\"\u003e\n\t\t\u003cspan class=\"included-header\"\u003eINCLUDED:\u003c\/span\u003e\u003cbr\u003eThe Applied Biosystems ViiA 7 Real-Time PCR System w\/ 384-Well Sample Block includes:\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003e384-Well Block\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003e384-Well Heated Cover\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eBackground Calibration Report\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eROI Calibration Report\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eUniformity Calibration Report\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eWindows 11 Professional 64-Bit Data Station with Flatscreen Monitor\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eQuantStudio Real-Time PCR Software Version 1.6.1 Installed\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003ePower Cord\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eOperator's Manual\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eFull 180 Day Parts and Labor Warranty\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\n\t\u003ch2\u003eApplied Biosystems ViiA 7 Real-Time PCR System w\/ 384-Well Sample Block Specifications\u003c\/h2\u003e\n\t\u003ctable\u003e\n\t\u003ctbody\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tBlock Configuration\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t384-Well (5 to 20 uL reactions)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tBlock Change Design\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tBlock change from front of instrument in less than 1 minute; no secondary tools required\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tRun Time\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t~ 35 minutes for 384-Well\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDemonstrated Sensitivity\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tDown to 1 copy\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDynamic Range\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tUp to 9 logs of linear dynamic range\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tResolution\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tDetect changes as little as 1.5-fold in target quantities in singleplex reaction\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tExcitation\/Detection Wavelengths\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t6 Excitation: 450 to 670 nm\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t6 Emission: 500 to 720 nm\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tData Export Format\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tFully configurable by user\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDimensions (W x D x H)\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t21 x 25 x 25.4 in. (53.3 x 63.5 x 64.5 cm)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tWeight\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t148 lb. (66.9 kg)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tElectrical Requirements\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t100-240V, 50\/60Hz, 12.5A\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\t\u003c\/table\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003ctable\u003e\n\t\u003ctbody\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd colspan=\"2\"\u003e\n\t\t\t\u003ccenter\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t\tComputer Specifications\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003c\/center\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\tProcessor\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\tIntel Core I5-8500 CPU\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\tRAM\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\t32.0 GB\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\tHard Drive\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\t500GB Internal SSD\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\tOperating System\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\tWindows 11 Professional, 64-bit\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\t\u003c\/table\u003e\n\t\u003cspan class=\"downloads-header\"\u003eDownloads\u003c\/span\u003e\n\t\u003cdiv class=\"downloads-section\"\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Applied_Biosystems_ViiA_7_Real-Time_PCR_System_with_384-Well_Sample_Block_-_Marshall_Scientific.pdf?v=1779986221\" target=\"blank\"\u003e\n\t\t\tTechnical Specification Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Applied_Biosystems_ViiA_7_Real-Time_PCR_System_with_384-Well_Sample_Block_Manual_-_Marshall_Scientific.pdf?v=1779986226\" target=\"blank\"\u003e\n\t\t\tOperator's Manual Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"formalquote2\"\u003e\n\t\t\u003ca class=\"formalquote2link\" href=\"\/formal_quote_a\/2902.htm\" target=\"blank\"\u003eRequest a Formal Quote\u003c\/a\u003e\n\t\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cspan class=\"windows11\"\u003e\u003c\/span\u003e","brand":"My Store","offers":[{"title":"Default Title","offer_id":42474438885466,"sku":"AB-VIIA384","price":7995.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AB-VIIA384-2.jpg?v=1761204262"},{"product_id":"applied-biosystems-7500-fast-dx-real-time-pcr-system","title":"Applied Biosystems 7500 Fast Dx Real-Time PCR System","description":"\u003cdiv class=\"productdescriptiontables\"\u003e\n\u003ch1\u003eApplied Biosystems 7500 Fast Dx Real-Time PCR System\u003c\/h1\u003e\n\u003cbr\u003e\u003cbr\u003e\n\u003cdiv class=\"highlights-divider\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"highlights-section\"\u003e\n\u003cdiv class=\"inner-highlight-div\"\u003e\n\u003cp class=\"inner-highlight\"\u003e\u003cb\u003eBlock Configuration\u003c\/b\u003e\u003cbr\u003e96-Well Fast\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"inner-highlight-div\"\u003e\n\u003cp class=\"inner-highlight\"\u003e\u003cb\u003ePeak Block Heating Rate\u003c\/b\u003e\u003cbr\u003e5.5°C\/second\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"inner-highlight-div\"\u003e\n\u003cp class=\"inner-highlight\"\u003e\u003cb\u003eTemperature Uniformity\u003c\/b\u003e\u003cbr\u003e± 1°C\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"highlights-divider\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"features-section\"\u003e\n\u003cdiv class=\"features-side\"\u003e\n\u003cspan class=\"features-header\"\u003eFeatures\u003c\/span\u003e\n\u003cul\u003e\n\u003cli\u003eFast cycling technology allows for more runs to be completed per day\u003c\/li\u003e\n\u003cli\u003eFaster ramp rates enable quick temperature changes without sacrificing performance\u003c\/li\u003e\n\u003cli\u003eHighly suitable for a variety of applications including gene expression analysis and DNA quantification\u003c\/li\u003e\n\u003cli\u003eIntegrated real-time PCR solutions with optimized reagents and customizable assays\u003c\/li\u003e\n\u003cli\u003eCapable of delivering results in less than 40 minutes\u003c\/li\u003e\n\u003cli\u003eOptical system includes CCD camera and halogen lamp with five excitation and emission filters\u003c\/li\u003e\n\u003cli\u003eSupports multiplexing of up to five targets per well\u003c\/li\u003e\n\u003cli\u003eFeatures a dynamic range of nine logs\u003c\/li\u003e\n\u003cli\u003eSensitivity to detect one copy of a template in 20 µL reactions with 99.7% confidence\u003c\/li\u003e\n\u003cli\u003eFDA 510(k)-cleared for In Vitro Diagnostic (IVD) use\u003c\/li\u003e\n\u003cli\u003eSDS v1.4.1 software features Security, Auditing and E-Signature features, which support regulated environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"features-side\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AB-7500F_36e391f5-c726-4d39-b288-8f0b1b307268.jpg?v=1779986097\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cbr\u003eThe Applied Biosystems 7500 Fast Dx Real-Time PCR System, FDA-cleared for In Vitro Diagnostic (IVD) use, delivers reliable, high-throughput detection of nucleic acid targets with five-color fluorescence capability. This system, built on over ten years of real-time PCR innovation, is tailored for high-throughput environments requiring both speed and accuracy. It features a unique 96-well Fast block that accommodates reaction volumes from 10 to 30 uL, but is optimized for 10 uL, ensuring consistent thermal uniformity across all samples. \u003cbr\u003e\u003cbr\u003eThe system's rapid ramp rates accelerate the processing times to deliver results in less than 40 minutes without compromising the extension times or the quality of the assay. This efficiency is matched by the system’s robust temperature controls, maintaining a uniformity of ± 1°C and an accuracy of ± 0.5°C, which are crucial for precise thermal cycling. Additionally, the optical system uses a CCD camera coupled with a halogen lamp for excitation, along with five excitation and emission filters, enabling sensitive multiplex detection of up to five targets per well. \u003cbr\u003e\u003cbr\u003eWith a dynamic range extending over nine logs, the 7500 Fast Dx can detect as little as one copy of a template in a 20 uL reaction with 99.7% confidence. This system is not only a testament to Applied Biosystems' legacy of quality and innovation but also an essential tool for modern laboratories focused on genetic analysis and molecular diagnostics. The SDS v1.4.1 software on the 7500 Fast Dx has Security, Auditing and E-Signature features, which support regulated environments. \u003cb\u003ePlease Note: We recommend performing a Dye Calibration for the Dye you plan on using for your application(s). Please refer to the Operator's Manual for instructions. This instrument has been discontinued by the manufacturer but remains suitable for validated IVD applications and laboratory use.\u003c\/b\u003e \u003cbr\u003e\u003cbr\u003eAll of our equipment is fully tested to perform at factory specifications before being shipped.\u003cbr\u003e\u003cbr\u003e\n\u003cdiv class=\"included-box\"\u003e\n\u003cspan class=\"included-header\"\u003eINCLUDED:\u003c\/span\u003e\u003cbr\u003eThe Applied Biosystems 7500 Fast Dx Real-Time PCR System includes:\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003e96-Well Fast Block\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eNew Halogen Lamp\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eBackground Calibration Report\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eROI Calibration Report\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eOptical Calibration Report\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eWindows 11 Professional 64-Bit Data Station\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eApplied Biosystems 7500 Dx SDS Software Version 1.4.1 Installed\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003ePower Cord\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eOperator's Manual\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eFull 180 Day Parts and Labor Warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003ch2\u003eApplied Biosystems 7500 Fast Dx Real-Time PCR System Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlock Configuration\u003c\/td\u003e\n\u003ctd\u003e96-Well Fast (10 to 30 uL reactions, optimized for 10 uL reactions)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample Format\u003c\/td\u003e\n\u003ctd\u003eFast 96-Well plates (100 uL) or 8-tube strips (100 uL)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e4°C to 99.9°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Uniformity\u003c\/td\u003e\n\u003ctd\u003e± 1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e± 0.5°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample Ramp Rate\u003c\/td\u003e\n\u003ctd\u003eFast mode: 3.5°C\/sec \u003cbr\u003eStandard mode: 1.6°C\/sec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak Block Heating Rate\u003c\/td\u003e\n\u003ctd\u003e5.5°C\/second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRun Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 40 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptical System\u003c\/td\u003e\n\u003ctd\u003eCCD camera with halogen lamp excitation; five-exciation and five-emission filters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDynamic Range\u003c\/td\u003e\n\u003ctd\u003e9 logs of linear dynamic range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003eDetection of 1 copy of template in 20 uL reaction for a single reporter TaqMan assay, with 99.7% confidence\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMultiplexing\u003c\/td\u003e\n\u003ctd\u003eUp to 5 targets per well\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDye Compatibility\u003c\/td\u003e\n\u003ctd\u003eFAM\/SYBR Green, VIC\/JOE, NED\/TAMRA\/Cy3, ROX\/Texas Red, and Cy5 (Calibration for new dyes within the wavelength range is possible by following the custom dye calibration procedure in the user’s manual)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePassive Reference Dyes\u003c\/td\u003e\n\u003ctd\u003eROX dye or any calibrated dye (use of a passive reference dye is optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e13.9 x 17.7 x 19.3 in. (34 x 45 x 49 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e75 lb. (34 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Requirements\u003c\/td\u003e\n\u003ctd\u003e100-240V, 50\/60Hz, 1080W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cspan class=\"downloads-header\"\u003eDownloads\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"downloads-section\"\u003e\n\u003cdiv class=\"pdf-button\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Applied_Biosystems_7500_Fast_Dx_Real-Time_PCR_System_-_Marshall_Scientific.pdf?v=1779986102\"\u003e Technical Specification Download \u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"pdf-button\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Applied_Biosystems_7500_Fast_Dx_Real-Time_PCR_System_Manual_-_Marshall_Scientific.pdf?v=1779986108\"\u003e Operator's Manual Download \u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"formalquote2\"\u003e\u003ca class=\"formalquote2link\" href=\"\/formal_quote_a\/3025.htm\"\u003eRequest a Formal Quote\u003c\/a\u003e\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Marshall scientific","offers":[{"title":"Default Title","offer_id":42502151962714,"sku":"AB-7500FDX","price":9995.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AB-7500FDX-2T.jpg?v=1780430591"},{"product_id":"applied-biosystems-openarray-accufill-system","title":"Applied Biosystems OpenArray AccuFill System","description":"\u003cdiv class=\"productdescriptiontables\"\u003e\n\t\u003ch1\u003eApplied Biosystems OpenArray AccuFill System\u003c\/h1\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-section\"\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eFill Rate\u003c\/b\u003e\u003cbr\u003e99.25%\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eMaximum Allowable Sample Carryover\u003c\/b\u003e\u003cbr\u003e\u0026lt; 1%\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eMaximum Allowable Assay Carryover\u003c\/b\u003e\u003cbr\u003e\u0026lt; 1%\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"features-section\"\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cspan class=\"features-header\"\u003eFeatures\u003c\/span\u003e\n\t\t\t\u003cul\u003e\n\t\t\t\t\u003cli\u003eAutomated transfer of samples and PCR master mix from 384-well plates to OpenArray plates\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eCapillary-based loading with self-metering through-holes for consistent reaction volumes\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eBubble-free dispensing enabled by an open-well, through-hole plate design\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eOptimized for high-throughput real-time PCR and genotyping workflows\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eCompatible with SYBR, OpenArray Real-Time PCR, TaqMan OpenArray Real-Time PCR, and TaqMan OpenArray Genotyping chemistries\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eHigh throughput equivalent to eight traditional 384-well plates per OpenArray plate\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eAbility to process up to four OpenArray plates per run for large-scale studies\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eIntuitive software for plate setup, sample mapping, file generation, and data integration\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eHigh performance metrics including a typical 99.25% fill rate and minimal sample or assay carryover\u003c\/li\u003e\n\t\t\t\u003c\/ul\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AB-OAAF.jpg?v=1779986129\"\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003eThe Applied Biosystems OpenArray AccuFill System is an automated, high-throughput sample loading platform designed to precisely transfer DNA samples and PCR master mix from standard 384-well plates onto OpenArray Plates for real-time PCR analysis. The system uses capillary action to draw samples into AccuFill tips and dispense them evenly across the OpenArray plate surface, where self-metering through-holes automatically fill to the correct reaction volume without the need for pressure-based dispensing or manual volume control. Because the OpenArray format contains no closed wells, air bubbles are not trapped during loading, resulting in highly uniform fills and excellent data consistency.\n\t\u003cbr\u003e\u003cbr\u003e\n\tOptimized specifically for downstream real-time PCR workflows, the AccuFill System supports SYBR, OpenArray Real-Time PCR, TaqMan OpenArray Real-Time PCR, and TaqMan OpenArray Genotyping chemistries. OpenArray technology significantly increases throughput and efficiency: a single QuantStudio™ 12K Flex OpenArray plate is equivalent to eight conventional 384-well plates, and the system can process up to four OpenArray plates per run. This enables laboratories to analyze up to 1,728 genotyping samples or 2,304 gene expression samples within an 8-hour workday, with the option for offline thermal cycling to further optimize instrument utilization.\n\t\u003cbr\u003e\u003cbr\u003e\n\tThe accompanying OpenArray AccuFill v2.0 software provides end-to-end workflow control, including sample plate setup, mapping from 96-well to 384-well formats, support for multi-sample loading, and generation of all required plate files (TPF, SPF, loaded files, and CSV outputs) for compatible Applied Biosystems™ real-time PCR instruments. The software also includes plate orientation correction, loading history tracking, and sample integration capabilities to streamline data management. Designed for reliability and reproducibility, the system delivers a typical fill rate of 99.25%, with maximum allowable sample and assay carryover below 1% and less than 5% data loss due to evaporation, making it a robust solution for high-density, high-confidence qPCR applications\n\t\u003cbr\u003e\u003cbr\u003eAll of our equipment is fully tested to perform at factory specifications before being shipped.\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"included-box\"\u003e\n\t\t\u003cspan class=\"included-header\"\u003eINCLUDED:\u003c\/span\u003e\u003cbr\u003eThe Applied Biosystems OpenArray AccuFill System includes:\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eOpenArray Plate Press 2\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eWaste Bin\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eWindows 11 Professional 64-Bit Data Station with Flatscreen Monitor\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eOpenArray AccuFill v2.0 Software Installed\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003ePower Cord\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eOperator's Manual\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eFull 180 Day Parts and Labor Warranty\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\n\t\u003ch2\u003eApplied Biosystems OpenArray AccuFill System Specifications\u003c\/h2\u003e\n\t\u003ctable\u003e\n\t\u003ctbody\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tFill Rate\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t99.25%\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tMaximum Allowable Sample Carryover\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u0026lt; 1%\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tMaximum Allowable Assay Carryover\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u0026lt; 1%\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tMaximum Number of Through-Hole Data Points Lost Due to Evaporation\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u0026lt; 5%\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDimensions (H x D x W)\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t34.5 x 40 x 42 in. (87.6 x 101.6 x 106.7 cm)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tWeight\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t243 lb. (110.2 kg)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tElectrical Requirements\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t100 to 240VAC, 50\/60Hz, 4A\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\t\u003c\/table\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003ctable\u003e\n\t\u003ctbody\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd colspan=\"2\"\u003e\n\t\t\t\u003ccenter\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t\tComputer Specifications\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003c\/center\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\tProcessor\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\tIntel Core I5-8500 CPU\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\tRAM\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\t32.0 GB\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\tHard Drive\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\t500GB Internal SSD\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\tOperating System\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\tWindows 11 Professional, 64-bit\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\t\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cspan class=\"downloads-header\"\u003eDownloads\u003c\/span\u003e\n\u003cdiv class=\"downloads-section\"\u003e\n\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Applied_Biosystems_QuantStudio_12K_Flex_Real-Time_PCR_System_-_Marshall_Scientific.pdf?v=1779986136\" target=\"blank\"\u003e\n\t\tTechnical Specification Download\n\t\t\u003c\/a\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Applied_Biosystems_OpenArray_AccuFill_System_Manual_-_Marshall_Scientific.pdf?v=1779986141\" target=\"blank\"\u003e\n\t\tOperator's Manual Download\n\t\t\u003c\/a\u003e\n\t\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"formalquote2\"\u003e\n\t\u003ca class=\"formalquote2link\" href=\"\/formal_quote_a\/3118.htm\" target=\"blank\"\u003eRequest a Formal Quote\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cspan class=\"windows11\"\u003e\u003c\/span\u003e\n\n\u003cstyle\u003e\n .fpt-container {\n  width: 50%;\n }\n .fpt-box {\n   width: 45%;\n }\n\u003c\/style\u003e","brand":"Marshall scientific","offers":[{"title":"Default Title","offer_id":43428344561754,"sku":"AB-OAAF","price":12840.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AB-OAAF-2T.jpg?v=1779979759"},{"product_id":"applied-biosystems-quantstudio-6-flex-real-time-pcr-system-w-384-well-sample-block","title":"Applied Biosystems QuantStudio 6 Flex Real-Time PCR System w\/ 384-Well Sample Block","description":"\u003cdiv class=\"productdescriptiontables\"\u003e\n\t\u003ch1\u003eApplied Biosystems QuantStudio 6 Flex Real-Time PCR System w\/ 384-Well Sample Block\u003c\/h1\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-section\"\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eRamp-Up Rate\u003c\/b\u003e\u003cbr\u003e3.5°C\/second\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eRamp-Down Rate\u003c\/b\u003e\u003cbr\u003e3.0°C\/second\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eWell-to-Well Variability\u003c\/b\u003e\u003cbr\u003e± 0.25°C\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"features-section\"\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cspan class=\"features-header\"\u003eFeatures\u003c\/span\u003e\n\t\t\t\u003cul\u003e\n\t\t\t\t\u003cli\u003eAdvanced multiplexing capabilities with interchangeable block formats for diverse applications\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eAccommodates four different block types including 96-well, 96-well Fast, 384-well (384-well block included)\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eSimplified workflow with intuitive software and touch-screen interface\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eTool-free block exchange enhances ease of use and operational efficiency\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eOptiFlex system features six decoupled excitation and emission filter channels with 21 filter combinations\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eDetects changes in target quantity as small as 1.5-fold in single-plex reactions\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eOffers a linear dynamic range of 10 logs for precise quantification\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eDesigned for high throughput with automation capabilities for streamlined processing\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eSupports a wide range of applications, including gene expression, SNP genotyping, and protein thermal shift experiments\u003c\/li\u003e\n\t\t\t\u003c\/ul\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AB-QS7F2_65de61c0-9df8-4555-9997-6cb4d8d6fbf2.jpg?v=1779986190\"\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003eThe Applied Biosystems QuantStudio 6 Flex Real-Time PCR System w\/ 384-Well Sample Block represents a significant advancement in PCR technology, offering extensive multiplexing capabilities and interchangeable block formats to support a wide array of real-time PCR applications. This system is designed to enhance research flexibility and precision, accommodating three different block types: 96-well, 96-well Fast, and 384-well. Moreover, the system's intuitive touch-screen interface, combined with automation-friendly features and tool-free block exchange, simplifies workflows and promotes efficiency in the laboratory setting.\n\t\u003cbr\u003e\u003cbr\u003e\n\tKey to the QuantStudio 6 Flex system's reliability are its advanced optical and thermal components, which ensure minimal variability both within and across instruments. The OptiFlex system, which consists of six independent excitation and emission filter channels with 21 filter combinations, allows for high flexibility in multiplexing and chemical reactions. This system is particularly effective in detecting subtle changes in target quantity, achieving a linear dynamic range over ten logs and facilitating sensitive data analysis in single-plex reactions.\n\t\u003cbr\u003e\u003cbr\u003e\n\tFor laboratories aiming to streamline their processes and increase throughput, the QuantStudio 6 Flex system is an ideal solution. It supports a variety of applications from gene regulation studies to protein thermal shift assays. Its high ramp-up and ramp-down rates of 3.5°C\/second and 3.0°C\/second respectively, along with low well-to-well variability (± 0.25°C), ensure rapid and consistent performance. Additionally, the system is designed for easy integration with robotics for automated setups, making it a powerful tool for high-throughput environments where precision and reliability are paramount. \u003cb\u003ePlease Note: We recommend performing a Dye Calibration for the Dye you plan on using for your application(s). Please refer to the Operator's Manual for instructions.\u003c\/b\u003e\n\t\u003cbr\u003e\u003cbr\u003eAll of our equipment is fully tested to perform at factory specifications before being shipped.\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"included-box\"\u003e\n\t\t\u003cspan class=\"included-header\"\u003eINCLUDED:\u003c\/span\u003e\u003cbr\u003eThe Applied Biosystems QuantStudio 6 Flex Real-Time PCR System w\/ 384-Well Sample Block includes:\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003e384-Well Block\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003e384-Well Heated Cover\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eNew Lamp\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eBackground Calibration Report\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eROI Calibration Report\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eUniformity Calibration Report\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eWindows 11 Professional 64-Bit Data Station with Flatscreen Monitor\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eQuantStudio Real-Time PCR Software Version 1.7.2 Installed\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003ePower Cord\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eOperator's Manual\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eFull 180 Day Parts and Labor Warranty\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\n\t\u003ch2\u003eApplied Biosystems QuantStudio 6 Flex Real-Time PCR System w\/ 384-Well Sample Block Specifications\u003c\/h2\u003e\n\t\u003ctable\u003e\n\t\u003ctbody\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tBlock Configuration\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t384-well\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tBlock Change Design\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tBlock change from front in less than 1 minute; no tools required\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tRamp-Up Rate\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t3.5°C\/second\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tRamp-Down Rate\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t3.0°C\/second\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tWell-to-Well Variability\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t± 0.25°C\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tRun Time\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t35 minutes\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tExcitation Source\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tOptiFlex system lamp\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDetection Channels\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tExcitation: 455 to 672 nm\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tEmission: 505 to 723 nm\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDimensions (H x W x D)\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t29.1 x 19.7 x 26 in. (73.8 x 50.1 x 66.1 cm)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tWeight\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t154.3 lb. (70 kg)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tElectrical Requirements\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t100-240V, 50\/60Hz, 12.5A\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\t\u003c\/table\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003ctable\u003e\n\t\u003ctbody\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd colspan=\"2\"\u003e\n\t\t\t\u003ccenter\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t\tComputer Specifications\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003c\/center\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\tProcessor\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\tIntel Core I5-8500 CPU\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\tRAM\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\t32.0 GB\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\tHard Drive\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\t500GB Internal SSD\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\tOperating System\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\tWindows 11 Professional, 64-bit\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\t\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cspan class=\"downloads-header\"\u003eDownloads\u003c\/span\u003e\n\u003cdiv class=\"downloads-section\"\u003e\n\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Applied_Biosystems_QuantStudio_6_Flex_Real-Time_PCR_System_-_Marshall_Scientific.pdf?v=1779986195\" target=\"blank\"\u003e\n\t\tTechnical Specification Download\n\t\t\u003c\/a\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Applied_Biosystems_QuantStudio_6_Flex_Real-Time_PCR_System_Manual_-_Marshall_Scientific.pdf?v=1779986201\" target=\"blank\"\u003e\n\t\tOperator's Manual Download\n\t\t\u003c\/a\u003e\n\t\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"formalquote2\"\u003e\n\t\u003ca class=\"formalquote2link\" href=\"\/formal_quote_a\/3128.htm\" target=\"blank\"\u003eRequest a Formal Quote\u003c\/a\u003e\n\u003c\/div\u003e\n\n\u003cstyle\u003e\n.fpt-container {\n  width: 50%;\n}\n.fpt-box {\n   width: 45%;\n}\na.fpt-button {\n  margin-top: 28px;\n}\n.fpt-box p {\n   height: 49px;\n}\n\u003c\/style\u003e\n\u003cspan class=\"windows11\"\u003e\u003c\/span\u003e","brand":"Marshall scientific","offers":[{"title":"Default Title","offer_id":43428346429530,"sku":"AB-QS6F384","price":16995.0,"currency_code":"USD","in_stock":true}]}],"url":"https:\/\/p2gnpt-0c.myshopify.com\/collections\/real-time-pcr-systems\/maximum-rt-pcr-ramp-rate_6-0c-per-second.oembed","provider":"Marshall Scientific","version":"1.0","type":"link"}