{"product_id":"agilent-1100-hplc-g1321a-fld-detector","title":"Agilent 1100 HPLC G1321A FLD Detector","description":"\u003cdiv class=\"productdescriptiontables\"\u003e\n\t\u003ch1\u003eAgilent 1100 HPLC G1321A Fluorescence Detector\u003c\/h1\u003e\n\t\u003cbr\u003e\n\t\u003cp class=\"MsoNormal\"\u003e\n\tThe Agilent 1100 HPLC G1321A Fluorescence Detector brings high-sensitivity and selection through simultaneous multi-wavelength detection. This easy-to-use detector provides quantitative data and fluorescence spectra from a single run. The FD's spectral information can be used for rapid method optimization and verification of separation quality.  \n\t\t\u003cbr\u003e\u003cbr\u003eAll of our equipment is fully tested to perform at factory\nspecifications before being shipped. \n\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\u003c\/p\u003e\n\t\u003cbr\u003e\n\t\u003cdiv class=\"included-box\"\u003e\n\t\t\u003cspan class=\"included-header\"\u003eINCLUDED:\u003c\/span\u003e\u003cbr\u003eThe Agilent 1100 HPLC G1321A FLD Detector includes:\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eFirmware Version 07.02 (Can be changed upon request)\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eLab Advisor Calibration Report\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003e 8μl Flow Cell\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003e Power Cord\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003e Operator's Manual\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003e Full 180 Day Parts and Labor Warranty\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"productdescriptiontables\"\u003e\n\t\t\u003cb\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/b\u003e\n\t\t\u003ch2\u003eAgilent 1100 HPLC G1321A Fluorescence Detector Specifications\u003c\/h2\u003e\n\t\t\u003ctable class=\"MsoNormalTable\" style=\"width:348pt; background-color: white;\" border=\"1\" cell=\"\" padding=\"0\" cellspacing=\"0\" width=\"464\"\u003e\n\t\t\u003c\/table\u003e\n\t\t\u003ctable border=\"1\"\u003e\n\t\t\u003ctbody\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\tDetection type\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cp class=\"MsoNormal\"\u003e\n\t\t\t\tMulti-signal fluorescence detector with rapid on-line \n\t\t\t\t\t\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003escanning capabilities and spectral \u003c\/span\u003e\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003edata analysis\u003c\/span\u003e\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\tPerformance Specifications\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cp class=\"MsoNormal\"\u003e\n\t\t\t\t10 fg Anthracene, Ex=250 nm, Em=400 nm*\n\t\t\t\t\t\u003cbr\u003e\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003eRAMAN (H2O) \u0026gt; 200 (FLF rev A)\u003cbr\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003eRAMAN (H2O) \u0026gt; 400 (FLF rev \u0026gt;A)\u003cbr\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003eEx=350 nm, Em=397 nm, dark \u003c\/span\u003e\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003evalue 450 nm, standard flow cell \u003c\/span\u003e\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003etime constant=4 seconds \u003c\/span\u003e\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003e(8 seconds response time)\u003c\/span\u003e\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\tLight source\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cp class=\"MsoNormal\"\u003e\n\t\t\t\tXenon Flash Lamp, normal mode 20 W, \n\t\t\t\t\t\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003eeconomy mode 5 W\u003c\/span\u003e\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\tPulse frequency\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cp class=\"MsoNormal\"\u003e\n\t\t\t\t296 Hz for single signal mode, 74 Hz for spectral mode\n\t\t\t\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\t\u003cp class=\"MsoNormal\"\u003e\n\t\t\t\t\t\u003co:p\u003e \u003c\/o:p\u003e\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\tExcitation monochromator\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cp class=\"MsoNormal\"\u003e\n\t\t\t\tRange: 200 nm - 700 nm and zero-order\n\t\t\t\t\t\u003cbr\u003eBandwidth: 20 nm (fixed)\u003cbr\u003e\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003eMonochromator:concave holographic grating, F\/1.6, blaze: 300\nnm\n\t\t\t\t\t\u003c\/span\u003e\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\tEmission monochromator\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cp class=\"MsoNormal\"\u003e\n\t\t\t\tRange: 280 nm - 900 nm and zero-order\n\t\t\t\t\t\u003cbr\u003eBandwidth: 20 nm (fixed)\u003cbr\u003e\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003eMonochromator:concave holographic grating, F\/1.6, blaze: 400\nnm\n\t\t\t\t\t\u003c\/span\u003e\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\tReference System\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\tin-line excitation measurement\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\tTimetable programming\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cp class=\"MsoNormal\"\u003e\n\t\t\t\tup to 4 signal wavelengths, response time, PMT Gain, \n\t\t\t\t\t\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003ebaseline behavior (append, free, \u003c\/span\u003e\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003ezero), spectral parameters\u003c\/span\u003e\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\tSpectrum acquisition\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cp class=\"MsoNormal\"\u003e\n\t\t\t\tExcitation or Emission spectra \n\t\t\t\t\t\u003cbr\u003eScan speed: 28 ms per datapoint \u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003e(e.g. 0.6 s\/spectrum 200-400 nm, 10 nm step)\u003cbr\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003eStep size: 1-20 nm\u003cbr\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003eSpectra storage: All\u003c\/span\u003e\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\tWavelength characteristic\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cp class=\"MsoNormal\"\u003e\n\t\t\t\tRepeatability ±0.2 nm\n\t\t\t\t\t\u003cbr\u003eAccuracy ±3 nm setting\n\t\t\t\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\tFlow cells\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cp class=\"MsoNormal\"\u003e\n\t\t\t\tStandard: 8 µl volume and 20 bar (2 MPa) pressure maximum, \n\t\t\t\t\t\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003equartz\u003cbr\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003eOptional: \u003c\/span\u003e\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003eFluorescence cuvette for offline \u003c\/span\u003e\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003espectroscopic measurements \u003c\/span\u003e\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003ewith 1 ml syringe, 8 µl volume, \u003c\/span\u003e\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003equartz\u003c\/span\u003e\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\tControl and data evaluation\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cp class=\"MsoNormal\"\u003e\n\t\t\t\tAgilent ChemStation for LC, Agilent 1100 Control Module with \n\t\t\t\t\t\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003elimited spectral data analysis and \u003c\/span\u003e\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003eprinting of spectra\u003c\/span\u003e\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\tAnalog outputs\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cp class=\"MsoNormal\"\u003e\n\t\t\t\tRecorder\/integrator: 100 mV or 1 V, output range \u0026gt;102 \n\t\t\t\t\t\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003eluminescence units, two outputs\u003c\/span\u003e\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\tCommunications\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cp class=\"MsoNormal\"\u003e\n\t\t\tController-area network (CAN), \n\t\t\t\t\t\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003eGPIB, RS-232C, LAN, APG\u003cbr\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003eRemote: ready, start, stop and shut-down signals\u003c\/span\u003e\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\tSafety and Maintenance\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cp class=\"MsoNormal\"\u003e\n\t\t\t\t\t\u003cspan style=\"background-color: initial; font-size: 1em;\"\u003eExtensive diagnostics, error d\u003c\/span\u003eetection and display (through \u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003econtrol module and ChemStation), \u003c\/span\u003e\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003eleak detection, safe leak handling, \u003c\/span\u003e\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003eleak output signal for shutdown of \u003c\/span\u003e\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003epumping system. Low voltages in \u003c\/span\u003e\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003emajor maintenance areas.\u003c\/span\u003e\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\tGLP Features\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cp class=\"MsoNormal\"\u003e\n\t\t\t\tEarly Maintenance Feedback (EMF) for continuous tracking of \n\t\t\t\t\t\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003einstrument usage in terms of lamp \u003c\/span\u003e\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003eburn time with user-settable \u003c\/span\u003e\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003elimits and feedback messages. \u003c\/span\u003e\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003eElectronic records of \u003c\/span\u003e\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003emaintenance and errors. \u003c\/span\u003e\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003eVerification of wavelength \u003c\/span\u003e\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003eaccuracy, using the Raman band \u003c\/span\u003e\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003eof water\u003c\/span\u003e\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\tHousing\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\tAll materials recyclable\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\tEnvironment\n\t\t\t\t\u003cbr\u003e\u003cbr\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cp class=\"MsoNormal\"\u003e\n\t\t\t\t0 to 40 °C constant temperature at \u0026lt;95% humidity \n\t\t\t\t\t\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003e(non-condensing)\u003c\/span\u003e\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\tDimensions and Weight\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cp class=\"MsoNormal\"\u003e\n\t\t\t\t140 mm x 345 mm x 435 mm (5.5 x 13.5 x 17 inches) \n\t\t\t\t\t\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003e(height x width x depth)\u003cbr\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial; font-size: 1em;\"\u003e25.5 lbs \u003c\/span\u003e\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003c\/tbody\u003e\n\t\t\u003c\/table\u003e\n\t\t\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/agilent_1100_hplc_G1321A_FLD-manual.pdf?v=1779984491\"\u003eAgilent G1321A FLD Manual \u003c\/a\u003e\u003cbr\u003e\u003cb\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/G1321A_specs_21eef44a-d6c9-4429-b213-9606be280bc2.pdf?v=1779984495\" target=\"blank\"\u003e\u003cimg src=\"\/v\/vspfiles\/images\/marshdoc.png\"\u003eClick Here to View all the Technical Specs for the G1321A FLD\u003c\/a\u003e\u003c\/b\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"formalquote2\"\u003e\n\t\t\u003ca class=\"formalquote2link\" href=\"\/formal_quote_a\/1929.htm\"\u003eRequest a Formal Quote\u003c\/a\u003e\n\t\u003c\/div\u003e\n\u003c\/div\u003e","brand":"My Store","offers":[{"title":"Default Title","offer_id":42474447503450,"sku":"AG-1100FLD","price":5395.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-1100FLD-2.jpg?v=1761204514","url":"https:\/\/p2gnpt-0c.myshopify.com\/products\/agilent-1100-hplc-g1321a-fld-detector","provider":"Marshall Scientific","version":"1.0","type":"link"}