{"product_id":"agilent-1200-hplc-g1316c-column-compartment","title":"Agilent 1200 HPLC G1316C Column Compartment","description":"\u003cdiv class=\"productdescriptiontables\"\u003e\n\t\u003ch1\u003eAgilent 1200 HPLC G1316C Column Compartment\n\t\u003c\/h1\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-section\"\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eTemperature Range\u003c\/b\u003e\u003cbr\u003e Ambient -10°C to 100°C\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eTemperature Stability\u003c\/b\u003e\u003cbr\u003e± 0.05°C\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eColumn Capacity \u003c\/b\u003e\u003cbr\u003e3 x 30 cm Columns\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"features-section\"\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cspan class=\"features-header\"\u003eFeatures\u003c\/span\u003e\n\t\t\t\u003cul\u003e\n\t\t\t\t\u003cli\u003eStackable, thermostatted column compartment designed for Agilent 1200 Series LC systems\u003c\/li\u003e\n\t\t\t\t\u003cli\u003ePeltier-based heating and cooling architecture for controlled column environments\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eHolds up to three 30 cm columns within an optimized, low-dead-volume layout\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eTwo independently programmable, low-volume heat exchangers for solvent conditioning\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eHeat exchanger design promotes uniform thermal conditions between solvent and column\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eElectronic column identification module supports GLP documentation\u003c\/li\u003e\n\t\t\t\t\u003cli\u003e\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003eDesigned for stable, reproducible chromatographic performance\u003c\/span\u003e\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eCompatible with standalone operation or integrated Agilent 1200 Series configurations\u003c\/li\u003e\n\t\t\t\u003c\/ul\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cimg src=\"https:\/\/www.marshallscientific.com\/v\/vspfiles\/feature-images\/.jpg\"\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\n\tThe Agilent 1200 HPLC G1316C Column Compartment is a thermostatted, stackable column compartment designed to deliver precise and stable temperature control for liquid chromatography applications where retention time reproducibility is critical. Engineered as part of the Agilent 1200 Series, the G1316C supports both heating and cooling using Peltier technology, allowing columns and mobile phase to be maintained under tightly controlled thermal conditions for consistent chromatographic performance.\n\t\u003cbr\u003e\t\u003cbr\u003e\n\tThe compartment accommodates up to three 30 cm columns and features an optimized internal design that minimizes dead volume while maintaining high efficiency. Temperature regulation is achieved through two independently programmable, low-volume heat exchangers that condition the solvent before it reaches the column. These heat exchangers are designed to closely match solvent and column temperatures through a combination of direct thermal contact, convection, and radiation, helping ensure uniform temperature conditions throughout the column.\n\t\u003cbr\u003e\t\u003cbr\u003e\n\tActual temperature control occurs at the heat exchanger level, with the system accounting for temperature offsets between the exchanger and column inlet. The displayed temperature reflects this corrected value, providing an accurate representation of operating conditions. An integrated electronic column identification module supports GLP documentation by recording column-specific information, while the overall thermal design allows rapid equilibration and stable operation across a wide range of flow rates and ambient conditions. Together, these features make the Agilent 1200 HPLC G1316C Column Compartment a reliable solution for applications requiring precise temperature control and reproducible chromatographic results.\n\t\u003cbr\u003e\u003cbr\u003eAll of our equipment is fully tested to perform at factory specifications before being shipped.\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"included-box\"\u003e\n\t\t\u003cspan class=\"included-header\"\u003eINCLUDED:\u003c\/span\u003e\u003cbr\u003eThe Agilent 1200 HPLC G1316C Column Compartment includes:\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eFirmware Version 07.02 (Can be changed upon request)\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eLab Advisor Diagnostic Report\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eSwitching Valve\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003ePower Cord\/Lan Cable\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eFront Cover\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eOperator's Manual\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eFull 180 Day Parts and Labor Warranty\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\n\t\u003ch2\u003eAgilent 1200 HPLC G1316C Column Compartment Specifications \u003c\/h2\u003e\n\t\u003ctable\u003e\n\t\u003ctbody\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tTemperature Range\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tAmbient -10°C to 100°C\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tTemperature Stability\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t± 0.05°C\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tTemperature Accuracy\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t± 0.8°C\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tColumn Capacity\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tThree 30 cm columns\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tWarm-Up \/ Cool-Down Time\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t5 minutes from ambient to 40°C \n\t\t\t\u003cbr\u003e10 minutes from 40°C to 20°C\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDead Volume\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t3 ul heat left heat exchanger\n\t\t\t\u003cbr\u003e 6 ul right heat exchanger\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDimensions (W x D x H)\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t16.1 x 17 x 5.5 in. (41 x 43.5 x 14 cm)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tWeight\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t22.5 lb. (10.2 kg.)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tElectrical Requirements\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t100-240V, 50\/60Hz, 320VA\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\t\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cspan class=\"downloads-header\"\u003eDownloads\u003c\/span\u003e\n\u003cdiv class=\"downloads-section\"\u003e\n\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_1200_HPLC_G1316C_Column_Compartment_-_Marshall_Scientific.pdf?v=1779984701\" target=\"blank\"\u003e\n\t\tTechnical Specification Download\n\t\t\u003c\/a\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_1200_HPLC_G1316_Series_Column_Compartments_Manual_-_Marshall_Scientific.pdf?v=1779984706\" target=\"blank\"\u003e\n\t\tOperator's Manual Download\n\t\t\u003c\/a\u003e\n\t\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"formalquote2\"\u003e\n\t\u003ca class=\"formalquote2link\" href=\"\/formal_quote_a\/3089.htm\" target=\"blank\"\u003eRequest a Formal Quote\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Marshall scientific","offers":[{"title":"Default Title","offer_id":43428346953818,"sku":"AG-1200COLC","price":2995.0,"currency_code":"USD","in_stock":false}],"url":"https:\/\/p2gnpt-0c.myshopify.com\/products\/agilent-1200-hplc-g1316c-column-compartment","provider":"Marshall Scientific","version":"1.0","type":"link"}