{"product_id":"agilent-1200-hplc-g1367b-high-performance-autosampler","title":"Agilent 1200 HPLC G1367B High Performance Autosampler","description":"\u003cdiv class=\"productdescriptiontables\"\u003e\n\t\u003ch1\u003eAgilent 1200 HPLC G1367B High Performance Autosampler\u003c\/h1\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-section\"\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eInjection Range\u003c\/b\u003e\u003cbr\u003e 0.1 – 100 µl in 0.1 µl increments\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003ePrecision\u003c\/b\u003e\u003cbr\u003e\t\nTypically \u0026lt; 0.25 % RSD from 5 – 100 µl\n\t\t\t\t\u003cbr\u003eTypically \u0026lt; 1 % RSD from 1 – 5 µl\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003ePressure Range \u003c\/b\u003e\u003cbr\u003e400 bar (5800 psi)\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"features-section\"\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cspan class=\"features-header\"\u003eFeatures\u003c\/span\u003e\n\t\t\t\u003cul\u003e\n\t\t\t\t\u003cli\u003eOverlapped injections maximize productivity by reducing cycle times between runs\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eMinimal delay volumes enable rapid gradients and fast system equilibration after sample injection\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eFlexible sample handling supports various container types, including well plates, vials, and Eppendorf tubes\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eAdvanced GLP features include early maintenance feedback (EMF) and electronic records of maintenance and errors\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eMultiple communication options with CAN, RS232C, APG remote, and optional external contact closures for seamless integration\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eBuilt-in safety features like leak detection, safe leak handling, and low voltages in maintenance areas ensure operational safety\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eFast injection cycle time of under 30 seconds for high-throughput workflows\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eExceptional carry-over reduction, typically \u0026lt; 0.01%, for cleaner and more accurate results\u003c\/li\u003e\n\t\t\t\u003c\/ul\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/G1367B_6ac4308a-2c33-411e-8244-0e0b8196b6bd.jpg?v=1779984787\"\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003eThe Agilent 1200 HPLC G1367B High Performance Autosampler adds maximum flexibility and fast injection cycles to your Agilent HPLC system. Whenever high sample throughput and speed of analysis are points to consider, the G1367B is the autosampler to choose. Featuring a standard injection range from 0.1 to 100 μl, the G1367B Autosampler provides increased sample injection speed for high sample throughput. Other features include: \u003cspan style=\"background-color: initial;\"\u003eoverlapped injections for increased productivity, minimal delay volumes for \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003erapid gradients and fast equilibration when bypassing the autosampler after \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003esample injection, flexible and convenient sample handling with different types \u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eof sample containers.\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003cbr\u003eAll of our equipment is fully tested to perform at factory specifications before being shipped. \u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"included-box\"\u003e\n\t\t\u003cspan class=\"included-header\"\u003eINCLUDED:\u003c\/span\u003e\u003cbr\u003eThe Agilent 1200 HPLC G1367B High Performance Autosampler includes:\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eFirmware Version 07.02 (Can be changed upon request)\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003e Vial Tray\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003e Lab Advisor Documentation\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003e Lan Cable \/ Power Cord\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003e Operator's Manual\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003e Full 180 Day Parts and Labor Warranty\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\u003c\/div\u003e\n\t\u003ch2\u003eAgilent 1200 HPLC G1367B High Performance Autosampler Specifications\u003c\/h2\u003e\n\t\u003ctable class=\"MsoTableGrid\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\t\u003ctbody\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd width=\"222\" valign=\"top\" style=\"width: 166.25pt; border-width: 1pt; border-color: windowtext; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\n\t\t\t\tGLP Features\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd width=\"318\" valign=\"top\" style=\"width: 238.5pt; border-top-width: 1pt; border-right-width: 1pt; border-bottom-width: 1pt; border-top-color: windowtext; border-right-color: windowtext; border-bottom-color: windowtext; border-left: none; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\n\t\t\t\tEarly maintainece feedback (EMF), electronic records of maintainence\n  and errors\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd width=\"222\" valign=\"top\" style=\"width: 166.25pt; border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; border-top: none; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\n\t\t\t\tCommunications\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd width=\"318\" valign=\"top\" style=\"width: 238.5pt; border-top: none; border-left: none; border-bottom-width: 1pt; border-bottom-color: windowtext; border-right-width: 1pt; border-right-color: windowtext; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\n\t\t\t\tController-area network (CAN). RS232C, APG remote standard, optional\n  four external contact closures and BCD vial number output\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd width=\"222\" valign=\"top\" style=\"width: 166.25pt; border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; border-top: none; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\n\t\t\t\tSafety Features\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd width=\"318\" valign=\"top\" style=\"width: 238.5pt; border-top: none; border-left: none; border-bottom-width: 1pt; border-bottom-color: windowtext; border-right-width: 1pt; border-right-color: windowtext; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\n\t\t\t\tLeak detection and safe leak handling, low voltages in maintence\n  areas, error detection and display\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd width=\"222\" valign=\"top\" style=\"width: 166.25pt; border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; border-top: none; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\n\t\t\t\tInjection Range\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd width=\"318\" valign=\"top\" style=\"width: 238.5pt; border-top: none; border-left: none; border-bottom-width: 1pt; border-bottom-color: windowtext; border-right-width: 1pt; border-right-color: windowtext; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\n\t\t\t\t0.1 – 100 µl in 0.1 µl increments Up to 1500 µl with multiple draw\n  (hardware modification required)\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd width=\"222\" valign=\"top\" style=\"width: 166.25pt; border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; border-top: none; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\n\t\t\t\tPrecision\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd width=\"318\" valign=\"top\" style=\"width: 238.5pt; border-top: none; border-left: none; border-bottom-width: 1pt; border-bottom-color: windowtext; border-right-width: 1pt; border-right-color: windowtext; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\n\t\t\t\tTypically \u0026lt; 0.25 % RSD from 5 – 100 µl, Typically \u0026lt; 1 % RSD\n  from 1 – 5 µl\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd width=\"222\" valign=\"top\" style=\"width: 166.25pt; border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; border-top: none; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\n\t\t\t\tPressure Range\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd width=\"318\" valign=\"top\" style=\"width: 238.5pt; border-top: none; border-left: none; border-bottom-width: 1pt; border-bottom-color: windowtext; border-right-width: 1pt; border-right-color: windowtext; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\n\t\t\t\t400 bar (5800 psi)\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd width=\"222\" valign=\"top\" style=\"width: 166.25pt; border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; border-top: none; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\n\t\t\t\tSample Viscosity Range\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd width=\"318\" valign=\"top\" style=\"width: 238.5pt; border-top: none; border-left: none; border-bottom-width: 1pt; border-bottom-color: windowtext; border-right-width: 1pt; border-right-color: windowtext; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\n\t\t\t\t0.2 – 5 cp\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd width=\"222\" valign=\"top\" style=\"width: 166.25pt; border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; border-top: none; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\n\t\t\t\tSample Capacity\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd width=\"318\" valign=\"top\" style=\"width: 238.5pt; border-top: none; border-left: none; border-bottom-width: 1pt; border-bottom-color: windowtext; border-right-width: 1pt; border-right-color: windowtext; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\n\t\t\t\t2 × well-plates (MTP) + 10 × 2 ml vials 108 x 2 ml vials in 2 x\n  54 vial plate plus 10 additional 2 mL vials 30 x 6-mL vials in 2 x 15\n  vial plate plus 10 additional 2 mL vials 54 Eppendorf tubes\n  (0.5\/1.5\/2.0mL) in 2 x 27 Eppendorf tube plate\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd width=\"222\" valign=\"top\" style=\"width: 166.25pt; border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; border-top: none; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\n\t\t\t\tInjection Cycle Time\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd width=\"318\" valign=\"top\" style=\"width: 238.5pt; border-top: none; border-left: none; border-bottom-width: 1pt; border-bottom-color: windowtext; border-right-width: 1pt; border-right-color: windowtext; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\n\t\t\t\tTypically \u0026lt; 30 s using following standard conditions: Default draw\n  speed: 200 µl\/min Default eject speed: 200 µl\/min Injection volume: 5 µl\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd width=\"222\" valign=\"top\" style=\"width: 166.25pt; border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; border-top: none; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\n\t\t\t\tCarry-Over\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd width=\"318\" valign=\"top\" style=\"width: 238.5pt; border-top: none; border-left: none; border-bottom-width: 1pt; border-bottom-color: windowtext; border-right-width: 1pt; border-right-color: windowtext; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\n\t\t\t\tTypically \u0026lt; 0.01 % using the following conditions: Column: 125 x 4\n  mm Hypersil ODS, 5 µm Mobile phase: Water\/Acetonitrile = 80\/20 Flow rate: 1\n  ml\/min Injection volume: 1 µl caffeine (1 mg\/ml), 5 µl water to test\n  carryover Outside wash of needle before injection: 20 sec with water using\n  flush port\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\t\u003c\/table\u003e\n\t\u003cspan class=\"downloads-header\"\u003eDownloads\u003c\/span\u003e\n\t\u003cdiv class=\"downloads-section\"\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/ag1200_g1367b_specs.pdf?v=1779984791\" target=\"blank\"\u003e\n\t\t\tTechnical Specification Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/ag1200_autosampler_manual.pdf?v=1779984795\" target=\"blank\"\u003e\n\t\t\tOperator's Manual Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\u003cdiv class=\"formalquote2\"\u003e\n\t\u003ca class=\"formalquote2link\" href=\"\/formal_quote_a\/2059.htm\"\u003eRequest a Formal Quote\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"My Store","offers":[{"title":"Default Title","offer_id":42474486333530,"sku":"AG-1367B","price":6695.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-1367B-2.jpg?v=1761205988","url":"https:\/\/p2gnpt-0c.myshopify.com\/products\/agilent-1200-hplc-g1367b-high-performance-autosampler","provider":"Marshall Scientific","version":"1.0","type":"link"}