{"product_id":"agilent-1200-hplc-g1367c-high-performance-autosampler-sl","title":"Agilent 1200 HPLC G1367C High Performance Autosampler SL","description":"\u003cdiv class=\"productdescriptiontables\"\u003e\n\t\u003ch1\u003eAgilent 1200 HPLC G1367C High Performance Autosampler SL\n\t\u003c\/h1\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-section\"\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eInjection Range\u003c\/b\u003e\u003cbr\u003e 0.1 to 100 ul in 0.1 ul increments\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003ePrecision\u003c\/b\u003e\u003cbr\u003e\t\nTypically \u0026lt; 0.25% RSD of peak areas from 5 to 100 ul\n\t\t\t\t\u003cbr\u003e Typically \u0026lt; 1% RSD of peak areas from 1 to 5 ul\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003ePressure Range \u003c\/b\u003e\u003cbr\u003eUp to 600 bar (8700 psi)\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"features-section\"\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cspan class=\"features-header\"\u003eFeatures\u003c\/span\u003e\n\t\t\t\u003cul\u003e\n\t\t\t\t\u003cli\u003eFast injection cycle times typically under 30 seconds to improve sample throughput\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eLow carryover performance for reliable and reproducible analytical results\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eSupports a wide range of sample viscosities for versatile application use\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eFlexible sample capacity including well plates, standard vials, and Eppendorf tubes\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eGLP features with early maintenance feedback and electronic records of maintenance and errors\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eIntegrated safety features including leak detection and safe leak handling\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eBuilt-in error detection and display for simplified troubleshooting\u003c\/li\u003e\n\t\t\t\u003c\/ul\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cimg src=\"https:\/\/www.marshallscientific.com\/v\/vspfiles\/feature-images\/AG-1367C.jpg\"\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\tThe Agilent 1200 HPLC G1367C High Performance Autosampler SL is a high-performance autosampler engineered for precise, reproducible injections and efficient liquid chromatography workflows. Designed to operate at pressures up to 600 bar, this system delivers consistent performance across demanding applications while maintaining excellent injection precision and minimal carryover. With a flexible injection range from 0.1 to 100 uL and fast cycle times typically under 30 seconds, the G1367C enhances throughput without compromising analytical accuracy. Low carryover performance and the ability to handle a broad sample viscosity range ensure reliable results across different sample types. Communication interfaces, including CAN, and RS232C, enable smooth integration with existing HPLC systems and laboratory workflows.\n\t\u003cbr\u003e\u003cbr\u003e\n\tBuilt with reliability and compliance in mind, the Agilent 1200 HPLC G1367C High Performance Autosampler SL includes GLP-focused features such as early maintenance feedback and electronic tracking of maintenance and errors. Safety features like leak detection, safe leak handling, and low-voltage maintenance areas provide added protection during operation. Combined with fast injection cycles and robust performance, this autosampler is well-suited for laboratories requiring high precision, efficiency, and dependable operation.\u003cbr\u003e\u003cbr\u003eAll of our equipment is fully tested to perform at factory specifications before being shipped. \u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"included-box\"\u003e\n\t\t\u003cspan class=\"included-header\"\u003eINCLUDED:\u003c\/span\u003e\u003cbr\u003eThe Agilent 1200 HPLC G1367C High Performance Autosampler SL includes:\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eFirmware Version 07.02 (Can be changed upon request)\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003e Vial Tray\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003e Lab Advisor Documentation\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003e Lan Cable \/ Power Cord\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003e Operator's Manual\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003e Full 180 Day Parts and Labor Warranty\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\u003c\/div\u003e\n\t\u003ch2\u003eAgilent 1200 HPLC G1367C High Performance Autosampler SL\n Specifications\n\t\u003c\/h2\u003e\n\t\u003ctable\u003e\n\t\u003ctbody\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tPressure\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tUp to 600 bar (8700 psi)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tGLP Features\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tEarly maintenance feedback (EMF), electronic records of maintenance and errors\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tCommunications\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tController-area network (CAN). RS232C, APG-remote standard, optional four external contact closures and BCD vial number output\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tSafety Features\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tLeak detection and safe leak handling, low voltages in maintenance areas, error detection and display\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tInjection Range\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t0.1 to 100 ul in 0.1 ul increments\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tPrecision\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tTypically \u0026lt; 0.25% RSD of peak areas from 5 to 100 ul\n\t\t\t\u003cbr\u003e Typically \u0026lt; 1% RSD of peak areas from 1 to 5 ul\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tCarryover\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tTypically \u0026lt; 0.01 % using the following conditions: Column: 125 x 4 mm Hypersil ODS, 5 µm\n\t\t\t\u003cbr\u003e Mobile phase: Water\/Acetonitrile = 80\/20\u003cbr\u003e Flow rate: 1 ml\/min \u003cbr\u003eInjection volume: 1 ul caffeine (1 mg\/ml), 5 µl water to test carryover \u003cbr\u003eOutside wash of needle before injection: 20 sec with water using flush port\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tSample Viscosity Range\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t0.2 to 50 cp\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tSample Capacity\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t2 × well plates (MTP) + 10 × 2 ml vials\n\t\t\t\u003cbr\u003e 108 x 2-mL vials in 2 x 54 vial plate plus 10 additional 2 mL vials\u003cbr\u003e 30 x 6-mL vials in 2 x 15 vial plate plus 10 additional 2 mL vials \u003cbr\u003e54 Eppendorf tubes (0.5\/1.5\/2.0mL) in 2 x 27 Eppendorf tube plate\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tInjection Cycle Time\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tTypically \u0026lt; 30 s using following standard conditions: \n\t\t\t\u003cbr\u003eDefault draw speed: 200 ul\/min \u003cbr\u003eDefault eject speed: 200 ul\/min\u003cbr\u003e Injection volume: 5 ul\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tAmbient Operating Temperature\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t 4 to 55°C (41 to 131°F)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDimensions (H x W x D)\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t13.5 x 17 x 8 in. (34.5 x 44 x 20 cm)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tWeight\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t34.2 lbs. (15.5 kg)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tElectrical Requirements\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t100-120V \/ 220-240V, 50\/60Hz\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\t\u003c\/table\u003e\n\t\u003cspan class=\"downloads-header\"\u003eDownloads\u003c\/span\u003e\n\t\u003cdiv class=\"downloads-section\"\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_1200_HPLC_G1367C_High_Performance_Autosampler_SL_-_Marshall_Scientific.pdf?v=1779985029\" target=\"blank\"\u003e\n\t\t\tTechnical Specification Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/ag1200_autosampler_manual.pdf?v=1779984795\" target=\"blank\"\u003e\n\t\t\tOperator's Manual Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"formalquote2\"\u003e\n\t\t\u003ca class=\"formalquote2link\" href=\"\/formal_quote_a\/3148.htm\" target=\"blank\"\u003eRequest a Formal Quote\u003c\/a\u003e\n\t\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Marshall scientific","offers":[{"title":"Default Title","offer_id":43428368154714,"sku":"AG-1367C","price":6995.0,"currency_code":"USD","in_stock":true}],"url":"https:\/\/p2gnpt-0c.myshopify.com\/products\/agilent-1200-hplc-g1367c-high-performance-autosampler-sl","provider":"Marshall Scientific","version":"1.0","type":"link"}