{"product_id":"agilent-1200-hplc-system-w-vwd","title":"Agilent 1200 HPLC System w\/ VWD","description":"\u003cdiv class=\"productdescriptiontables\"\u003e\n\t\u003ch1\u003eAgilent 1200 HPLC System with Variable Wavelength Detector\u003c\/h1\u003e\n\t\u003cp class=\"MsoNormal\"\u003e\n\t\t\u003cbr\u003eThe Agilent 1200 HPLC System guarantees the most efficient\nmixing and pulse-free solvent delivery for consistently fast and accurate\nresults. The system’s optimized design using a quaternary pump allows variable\nstroke volumes for stable solvent flow. This electronically activated inlet\nvalve runs synchronous to the pistons to eliminate vapor formation in volatile\nsolvent, making the Agilent 1200 both remarkably easy-to-use and\nmaintenance-free. It also features a high-speed proportioning valve and a\npre-configured degasser, which allow convenient low-pressure mixing and a large\nsolvent choice flexibility. The HPLC System’s vacuum degasser ensures reduced\noperating costs without the use of helium and optimum instrument performance. \n\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\u003c\/p\u003e\n\t\u003cp class=\"MsoNormal\"\u003e\n\t\t\u003cbr\u003eThe Agilent 1200 VWD \u003cspan style=\"color: rgb(74, 74, 74); font-family: Roboto, sans-serif; font-size: 15px; background-color: rgb(250, 250, 250);\"\u003eoffers programmable wavelength switching for sensitivity and optimized selectivity optimized to each analyte’s elution, along with stop-flow wavelength scanning for quick wavelength optimization.\u003c\/span\u003e The Agilent 1200’s\ntemperature management system ensures optimum baseline stability-even under\nrough ambient conditions. This detector features superb illumination using\ncombined deuterium and tungsten lamps for the highest intensity and lowest\ndetection limit from 190 to 950 nm, 1024 diodes and 1-nm slit for highest\nspectral resolution. The programmable slit helps you explore the spectral\nlandscape for faster sample characterization, ensuring higher sensitivity or\nlower baseline noise as necessary on the 1200. Slit settings can be stored and\nreported from 1 – 16 nm with raw data for GLP traceability.\n\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\u003c\/p\u003e\n\t\u003cp class=\"MsoNormal\"\u003e\n\t\t\u003cbr\u003eThe unit can be operated with a hand-held controller or\ncomputer running Clarity software. The HPLC System features extensive\ndiagnostics with compatible data analysis software for on-site and remote\ntrouble-shooting.\n\t\u003c\/p\u003e\n\t\u003cp class=\"MsoNormal\"\u003e\n\t\t\u003cbr\u003eThis Agilent system is in excellent condition and will be fully tested to perform at factory\nspecifications before being shipped.\n\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\u003c\/p\u003e\n\t\u003cbr\u003e\n\t\u003cdiv class=\"included-box\"\u003e\n\t\t\u003cspan class=\"included-header\"\u003eINCLUDED:\u003c\/span\u003e\u003cbr\u003eThe Agilent 1200 HPLC System w\/ VWD includes:\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eG1311A Quaternary Pump or G1312A Binary Pump\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eG1329A Thermal Autosampler\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eG1330B Thermal Unit\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eG1314A VWD Detector\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eG1316A TCC \u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eG1379B Degasser\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eWindows 11 Professional 64-Bit Data Station with Flatscreen Monitor\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eChemstation version 4.3 Software installed\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eCan\/Crossover Cables\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eAgilent G1369 Lan Interface Card\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eSolvent Tubing\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003e4 x Bottles, Caps and Solvent Filters\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eNew Stainless Steel Capillaries\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003e1\/4\" Wrench \u0026amp; Mobile Phase Priming Syringe\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eWaste Tubing\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eAll Power Cords\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eAgilent 4 Peak Test w\/ Lab Advisor Diagnostics Report\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eFull 180 Day Parts and Labor Warranty\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"agilent-tests\"\u003e\n\t\t\u003cspan class=\"agilent-tests-title\"\u003eBelow is a List of Diagnostic Tests Performed On This System\u003c\/span\u003e\u003cbr\u003e\n\t\t\u003cspan class=\"agilent-tests-header\"\u003eG1314A Variable Wavelength Detector Diagnostic Tests:\u003c\/span\u003e\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003eFilter Test: The test moves the filter into the light path and measures the relative absorbance in the filter position.\u003c\/li\u003e\n\t\t\t\u003cli\u003eDark Current Test: The test measures the dark current from the detector optic.\u003c\/li\u003e\n\t\t\t\u003cli\u003eHolmium Oxide Test: The test measures the Holmium spectrum from the built-in Holmium filter. The spectrum is evaluated for peaks at different wavelengths.\u003c\/li\u003e\n\t\t\t\u003cli\u003eLamp Intensity Test: The test verifies functionality of the UV lamp at various wavelengths.\u003c\/li\u003e\n\t\t\t\u003cli\u003eWavelength Intensity Test: The test confirms the accuracy of wavelengths measured.\u003c\/li\u003e\n\t\t\t\u003cli\u003e Baseline Noise Test: The test measures the amount of baseline noise drift identified by the detector.\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\t\u003cspan class=\"agilent-tests-header\"\u003eG1311A Quaternary Pump Diagnostic Tests:\u003c\/span\u003e\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003ePressure Test: The pressure test is a quick, built-in test designed to demonstrate the pressure tightness (up to 400 bar) of the system.\u003c\/li\u003e\n\t\t\t\u003cli\u003eLeak Test: The leak test is a built-in troubleshooting designed to demonstrate the leak-tightness of the pump.\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\t\u003cspan class=\"agilent-tests-header\"\u003eG1316A Column Compartment Diagnostic Tests:\u003c\/span\u003e\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003eThermostat Test: Evaluates the cooling and heating performance of the two Peltier elements.\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\t\u003cspan class=\"agilent-tests-header\"\u003eG1329A Autosampler Diagnostic Tests:\u003c\/span\u003e\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e Injector Steps: Performs each movement of the sampling sequence under manual control. This is useful for confirming autosampler functionality.\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\t\u003cspan class=\"agilent-tests-header\"\u003eSystem Tests:\u003c\/span\u003e\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e4 Peak Test (Isocratic Standard): Standard test published by Agilent to confirm complete functionality of the 1200 HPLC System.\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\u003c\/div\u003e\n\t\u003ch2\u003eAgilent 1200 HPLC System with VWD Detector Specifications\u003c\/h2\u003e\n\t\u003ctable class=\"MsoNormalTable\" style=\"width:348pt; background-color: white;\" border=\"1\" cell=\"\" padding=\"0\" cellspacing=\"0\" width=\"464\"\u003e\n\t\u003c\/table\u003e\n\t\u003ctable border=\"1\"\u003e\n\t\u003ctbody\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cb\u003eType\u003c\/b\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cb\u003eSpecification\u003c\/b\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\tDetection type\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t1024-element photodiode array\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\tLight Source\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\tDeuterium and tungsten lamps\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\tWavelength Range\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t190 - 950 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\tShort term noise (ASTM) Single \n\t\t\t\u003cbr\u003eand Multi-Wavelength\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t± 1 × 10-5AU at 254 and 750 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\tDrift\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t 2 × 10-3AU\/hr at 254 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\tLinear Absorbance range\n\t\t\t\u003cbr\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\u0026gt; 2 AU (upper limit)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\tWavelength accuracy\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t ± 1 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\tSlit width\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t 1, 2, 4 , 8, 16 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cbr\u003eDiode Width\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\u0026lt; 1 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\tFlow Cell\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp class=\"MsoNormal\"\u003e\n\t\t\tStandard: 13 µl volume, 10 mm cell \n\t\t\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp class=\"MsoNormal\"\u003e\n\t\t\tpath length and 120 bar (1760 psi) \n\t\t\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp class=\"MsoNormal\"\u003e\n\t\t\tpressure maximum\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\tControl and Data Evaluation\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\tAgilent ChemStation for LC\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\tAnalog Outputs\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cspan style=\"font-size: 14px; background-color: initial;\"\u003eRecorder\/integrator: 100 mV or 1 V,\u003c\/span\u003e\n\t\t\t\u003cp class=\"MsoNormal\"\u003e\n\t\t\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp class=\"MsoNormal\"\u003e\n\t\t\toutput range 0.001 – 2 AU, two \n\t\t\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp class=\"MsoNormal\"\u003e\n\t\t\toutputs\n\t\t\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\tCommunications\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp class=\"MsoNormal\"\u003e\n\t\t\tController-area network (CAN), GPIB, \n\t\t\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp class=\"MsoNormal\"\u003e\n\t\t\tRS-232C, APG Remote: ready, start, \n\t\t\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp class=\"MsoNormal\"\u003e\n\t\t\tstop and shut-down signals, LAN \n\t\t\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp class=\"MsoNormal\"\u003e\n\t\t\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cspan style=\"font-size: 14px; background-color: initial;\"\u003eoptional\u003c\/span\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\tSafety and Maintenance\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cspan style=\"font-size: 14px; background-color: initial;\"\u003eExtensive diagnostics, error detection\u003c\/span\u003e\n\t\t\t\u003cp class=\"MsoNormal\"\u003e\n\t\t\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp class=\"MsoNormal\"\u003e\n\t\t\tand display (through control module \n\t\t\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp class=\"MsoNormal\"\u003e\n\t\t\tand ChemStation), leak detection, safe \n\t\t\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp class=\"MsoNormal\"\u003e\n\t\t\tleak handling, leak output signal for \n\t\t\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp class=\"MsoNormal\"\u003e\n\t\t\tshutdown of pumping system. Low \n\t\t\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp class=\"MsoNormal\"\u003e\n\t\t\tvoltages in major maintenance areas.\n\t\t\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\tGLP Features\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cspan style=\"font-size: 14px; background-color: initial;\"\u003eEarly maintenance feedback (EMF) for\u003c\/span\u003e\n\t\t\t\u003cp class=\"MsoNormal\"\u003e\n\t\t\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp class=\"MsoNormal\"\u003e\n\t\t\tcontinuous tracking of instrument \n\t\t\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp class=\"MsoNormal\"\u003e\n\t\t\tusage in terms of lamp burn time with \n\t\t\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp class=\"MsoNormal\"\u003e\n\t\t\tuser-settable limits and feedback \n\t\t\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp class=\"MsoNormal\"\u003e\n\t\t\tmessages. Electronic records of \n\t\t\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp class=\"MsoNormal\"\u003e\n\t\t\tmaintenance and errors. Verification of \n\t\t\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp class=\"MsoNormal\"\u003e\n\t\t\twavelength accuracy with built-in \n\t\t\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp class=\"MsoNormal\"\u003e\n\t\t\tholmium oxide filter.\n\t\t\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\tHousing\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\tAll Materials recyclable\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\t\u003c\/table\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003ctable\u003e\n\t\u003ctbody\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd colspan=\"2\"\u003e\n\t\t\t\u003ccenter\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tComputer Specifications\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003c\/center\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tProcessor\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tIntel Core I5-8500 CPU\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tRAM\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t32.0 GB\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tHard Drive\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t500GB Internal SSD\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tOperating System\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tWindows 11 Professional, 64-bit\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\t\u003c\/table\u003e\n\u003cbr\u003e\n\t\u003cspan class=\"downloads-header\"\u003eDownloads\u003c\/span\u003e\n\t\u003cdiv class=\"downloads-section\"\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Ag1100DADsystem_specs_5edb23b4-826d-468b-9318-db2028eefbed.pdf?v=1779984595\" target=\"blank\"\u003e\n\t\t\tTechnical Specification Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_1200_Series_-_Marshall_Scientific.pdf?v=1779985051\" target=\"blank\"\u003e\n\t\t\tOperator's Manual Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\u003cdiv class=\"formalquote2\"\u003e\n\t\u003ca class=\"formalquote2link\" href=\"\/formal_quote_a\/2195.htm\"\u003eRequest a Formal Quote\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cspan class=\"windows11\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e","brand":"My Store","offers":[{"title":"Agilent 1200 G1311A Quaternary Pump \/ No Additional Detector Needed","offer_id":42474458185818,"sku":"AG-1200VWD","price":21595.0,"currency_code":"USD","in_stock":true},{"title":"Agilent 1200 G1311A Quaternary Pump \/ Agilent 1200 HPLC G1362A RID Detector","offer_id":42474458218586,"sku":"AG-1200VWD","price":31590.0,"currency_code":"USD","in_stock":true},{"title":"Agilent 1200 G1312A Binary Pump \/ No Additional Detector Needed","offer_id":42474458251354,"sku":"AG-1200VWD","price":20395.0,"currency_code":"USD","in_stock":true},{"title":"Agilent 1200 G1312A Binary Pump \/ Agilent 1200 HPLC G1362A RID Detector","offer_id":42474458284122,"sku":"AG-1200VWD","price":30390.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-1200VWD-2.jpg?v=1761204848","url":"https:\/\/p2gnpt-0c.myshopify.com\/products\/agilent-1200-hplc-system-w-vwd","provider":"Marshall Scientific","version":"1.0","type":"link"}