{"product_id":"agilent-1260-infinity-i-hplc-g1321b-fld-detector","title":"Agilent 1260 Infinity I HPLC G1321B FLD Detector","description":"\u003cdiv class=\"productdescriptiontables\"\u003e\n\t\u003ch1\u003eAgilent 1260 Infinity I HPLC G1321B FLD Detector\u003c\/h1\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-section\"\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eDetection Type\u003c\/b\u003e\u003cbr\u003e Multi-Signal Fluorescence w\/ Rapid On-Line Scanning and Spectral Data Analysis\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eLight Source\u003c\/b\u003e\u003cbr\u003e\t\nXenon Flash Lamp\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eStandard Flow Cell \u003c\/b\u003e\u003cbr\u003e8 µl volume and 20 bar\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"features-section\"\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cspan class=\"features-header\"\u003eFeatures\u003c\/span\u003e\n\t\t\t\u003cul\u003e\n\t\t\t\t\u003cli\u003eSimultaneous multi-wavelength detection enables efficient data collection and analysis in a single run\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eTimetable programming allows control of up to four signal wavelengths with customizable response times and spectral parameters\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eHigh-speed spectrum acquisition with scan speeds of 28 ms per data point for rapid analysis\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eBuilt-in wavelength accuracy verification ensures consistent and reliable performance\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eEasy maintenance with front access for quick component replacement\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eCompact and lightweight design (7 x 13.5 x 17 in., 26 lb.) for easy integration into lab setups\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eGLP-compliant design supports laboratory quality standards and operational safety\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eOptional cuvette accessory available for off-line spectroscopic measurements\u003c\/li\u003e\n\t\t\t\u003c\/ul\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-1260FLD-3_4932f330-c8d0-4a28-98d4-67132535864c.jpg?v=1779985177\"\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\n\t\u003cp class=\"MsoNormal\"\u003e\n\tThe Agilent 1260 Infinity I HPLC G1321B FLD Detector brings high-sensitivity and selection through simultaneous multi-wavelength detection. This easy-to-use detector provides quantitative data and fluorescence spectra from a single run. The G1321B is also designed for the highest optical performance, GLP compliance, and easy maintenance. Some of the features of the G1321B FLD Detector include; a flash lamp for highest intensity and lowest detection limit, multi-wavelength mode for on-line spectra, spectra acquisition and simultaneous multi-signal detection, easy front access to the flow cell for fast replacement, and built-in wavelength accuracy verification. Users may also use an optional cuvette for off-line measurements.\n\t\t\u003cbr\u003e\u003cbr\u003eAll of our equipment is fully tested to perform at factory\nspecifications before being shipped.\n\t\t\u003cbr\u003e\u003cbr\u003e\n\t\u003c\/p\u003e\n\t\u003cdiv class=\"included-box\"\u003e\n\t\t\u003cspan class=\"included-header\"\u003eINCLUDED:\u003c\/span\u003e\u003cbr\u003eThe Agilent 1260 Infinity I HPLC G1321B FLD Detector includes:\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eFirmware Version 07.02 (Can be changed upon request)\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003e Calibration Report\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003e 8μl Flow Cell\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003e Lab Advisor Calibration Report\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003e Lan Cable \/ Power Cord\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003e Operator's Manual\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003e Full 180 Day Parts and Labor Warranty\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\n\t\u003ch2\u003eAgilent 1260 Infinity I HPLC G1321B FLD Detector Specifications\u003c\/h2\u003e\n\t\u003ctable\u003e\n\t\u003ctbody\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tDetection Type\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tMulti-signal fluorescence detector with rapid on-line scanning capabilities and spectral data analysis\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tPerformance Specifications\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tSingle wavelength operation: • RAMAN (H2O) \u0026gt; 500 (noise reference measured at signal) Ex=350 nm, Em=397 nm, dark value 450 nm, standard flow cell • RAMAN (H2O) \u0026gt; 3000 (noise reference measured at dark value) Ex=350 nm, Em=397 nm, dark value 450 nm, standard flow cell Dual wavelength operation: RAMAN (H2O) \u0026gt; 300 Ex 350 nm, Em 397 nm and Ex 350 nm, Em 450 nm, standard flow cell.\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tLight source\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tXenon Flash Lamp, normal mode 20 W, economy mode 5 W, lifetime 4000 h\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tPulse frequency\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t296 Hz for single signal mode 74 Hz for economy mode\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tExcitation Monochromator\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tRange: settable 200 nm - 1200 nm and zero-order Bandwidth: 20 nm (fixed) Monochromator: concave holographic grating, F\/1.6, blaze: 300 nm\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tEmission Monochromator\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tRange: settable 200 nm - 1200 nm and zero-order Bandwidth: 20 nm (fixed) Monochromator: concave holographic grating, F\/1.6, blaze: 400 nm\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tReference System:\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tin-line excitation measurement\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tTimetable programing\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tup to 4 signal wavelengths, response time, PMT Gain, baseline behavior (append, free, zero), spectral parameters\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tSpectrum acquisition:\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tExcitation or Emission spectra Scan speed: 28 ms per datapoint (e.g. 0.6 s\/spectrum 200 – 400 nm, 10 nm step) Step size: 1 – 20 nm Spectra storage: All\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tWavelength characteristic\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tRepeatability+\/- 0.2 nm Accuracy+\/- 3 nm setting\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tFlow cells\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tStandard: 8 µl volume and 20 bar (2 MPa) pressure maximum, quartz Optional: Fluorescence cuvette for offline spectroscopic measurements with 1 ml syringe, 8 µl volume, quartz\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDimensions (H x W x D)\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t7 x 13.5 x 17 in. (14 x 34.5 x 43.5 cm)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tWeight\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t26 lb. (11.5 kg.)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\t\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cspan class=\"downloads-header\"\u003eDownloads\u003c\/span\u003e\n\u003cdiv class=\"downloads-section\"\u003e\n\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_1260_Infinity_I_G1321B_FLD_Detector_-_Marshall_Scientific.pdf?v=1779985180\" target=\"blank\"\u003e\n\t\tTechnical Specification Download\n\t\t\u003c\/a\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_1260_Infinity_I_G1321B_FLD_Detector_Manual_-_Marshall_Scientific.pdf?v=1779985185\" target=\"blank\"\u003e\n\t\tOperator's Manual Download\n\t\t\u003c\/a\u003e\n\t\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"formalquote2\"\u003e\n\t\u003ca class=\"formalquote2link\" href=\"\/formal_quote_a\/2413.htm\" target=\"blank\"\u003eRequest a Formal Quote\u003c\/a\u003e\n\u003c\/div\u003e","brand":"My Store","offers":[{"title":"Default Title","offer_id":42474472013914,"sku":"AG-1260FLD","price":9995.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-1260FLD-2.jpg?v=1761205072","url":"https:\/\/p2gnpt-0c.myshopify.com\/products\/agilent-1260-infinity-i-hplc-g1321b-fld-detector","provider":"Marshall Scientific","version":"1.0","type":"link"}