{"product_id":"agilent-1260-infinity-i-hplc-g1322a-degasser","title":"Agilent 1260 Infinity I HPLC G1322A Degasser","description":"\u003cdiv class=\"productdescriptiontables\"\u003e\n\t\u003ch1\u003eAgilent 1260 Infinity I HPLC G1322A Degasser\u003c\/h1\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-section\"\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eMaximum Flow Rate\u003c\/b\u003e\u003cbr\u003e 10 ml\/min per channel\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eNumber of Channels\u003c\/b\u003e\u003cbr\u003e\t4\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eInternal Volume per Channel\u003c\/b\u003e\u003cbr\u003eTypically 12 mL per channel\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"features-section\"\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cspan class=\"features-header\"\u003eFeatures\u003c\/span\u003e\n\t\t\t\u003cul\u003e\n\t\t\t\t\u003cli\u003eMembrane-based degassing design removes dissolved gases from mobile phases\u003c\/li\u003e\n\t\t\t\t\u003cli\u003ePressure sensor continuously monitors vacuum conditions during operation\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eAutomatic switching between operating modes to maintain effective degassing\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eBuilt-in diagnostics detect abnormal vacuum conditions and trigger protective responses\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eStatus indicators provide clear visual feedback on operating and error states\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eError output supports system monitoring and fault reporting\u003c\/li\u003e\n\t\t\t\t\u003cli\u003e\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003eDesigned to support stable baselines and reproducible chromatographic performance\u003c\/span\u003e\u003c\/li\u003e\n\t\t\t\u003c\/ul\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-1260IDG.jpg?v=1779985189\"\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\tThe Agilent 1260 Infinity I HPLC G1322A Degasser is designed to effectively remove dissolved gases from mobile phases, helping ensure stable pump performance and consistent chromatographic results. The system uses a four-channel vacuum container with tubular membrane technology, allowing solvents to pass through gas-permeable membranes where dissolved gases are efficiently removed under controlled vacuum conditions. Vacuum generation and regulation are automatically managed by an internal pump and pressure sensor, which maintain the appropriate vacuum level during operation. The degasser continuously monitors system pressure and adjusts pump activity as needed to keep the vacuum within defined operating limits. Multiple operating modes support reliable degassing under varying conditions, while integrated diagnostics detect abnormal vacuum levels and initiate protective responses in the event of a fault.\n\t\u003cbr\u003e\u003cbr\u003e\n\tBuilt for dependable day-to-day LC operation, the G1322A provides consistent solvent degassing with minimal user intervention. Its controlled vacuum management, membrane-based degassing design, and integrated monitoring functions make it a reliable component for maintaining baseline stability and reproducible performance in Agilent 1260 Infinity LC systems.\n\t\u003cbr\u003e\u003cbr\u003eAll of our equipment is fully tested to perform at factory specifications before being shipped.   \u003cbr\u003e\n\t\u003cbr\u003e\n\t\u003cdiv class=\"included-box\"\u003e\n\t\t\u003cspan class=\"included-header\"\u003eINCLUDED:\u003c\/span\u003e\u003cbr\u003eThe Agilent 1260 Infinity I HPLC G1322A Degasser includes:\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eFront Cover\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003ePower Cord\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eOperator's Manual\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eFull 180 Day Parts and Labor Warranty\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\n\t\u003ch2\u003eAgilent 1260 Infinity I HPLC G1322A Degasser Specifications\u003c\/h2\u003e\n\t\u003ctable\u003e\n\t\u003ctbody\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tMaximum Flow Rate\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t10 ml\/min per channel\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tNumber of Channels\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t4\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tInternal Volume per Channel\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tTypically 12 mL per channel\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tMaterials in Contact with Solvent\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t PTFE, PEEK\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tpH Range\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t1 to 14\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDimensions (H x W x D)\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t13.5 x 17 x 3.1 in. (34.5 x 43.5 x 8 cm)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tWeight\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t16 lb. (7 kg.)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tElectrical Requirements\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t100-240V, 50\/60Hz, 5W\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\t\u003c\/table\u003e\n\t\u003cspan class=\"downloads-header\"\u003eDownloads\u003c\/span\u003e\n\t\u003cdiv class=\"downloads-section\"\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_1260_Infinity_I_HPLC_G1322A_Degasser_-_Marshall_Scientific.pdf?v=1779985193\" target=\"blank\"\u003e\n\t\t\tTechnical Specification Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_1260_Infinity_I_HPLC_G1322A_Degasser_Manual_-_Marshall_Scientific.pdf?v=1779985197\" target=\"blank\"\u003e\n\t\t\tOperator's Manual Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"formalquote2\"\u003e\n\t\t\u003ca class=\"formalquote2link\" href=\"\/formal_quote_a\/3090.htm\" target=\"blank\"\u003eRequest a Formal Quote\u003c\/a\u003e\n\t\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Marshall scientific","offers":[{"title":"Default Title","offer_id":43428350591066,"sku":"AG-1260IDG","price":2995.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-1260IDG-2T.jpg?v=1779980153","url":"https:\/\/p2gnpt-0c.myshopify.com\/products\/agilent-1260-infinity-i-hplc-g1322a-degasser","provider":"Marshall Scientific","version":"1.0","type":"link"}