{"product_id":"agilent-1260-infinity-i-hplc-g1329b-autosampler","title":"Agilent 1260 Infinity I HPLC G1329B Autosampler","description":"\u003cdiv class=\"productdescriptiontables\"\u003e\n\t\u003ch1\u003eAgilent 1260 Infinity I HPLC G1329B Autosampler\u003c\/h1\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-section\"\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eInjection Range\u003c\/b\u003e\u003cbr\u003e0.1 – 100 µl\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eInjection Precision\u003c\/b\u003e\u003cbr\u003e\n\t\t\t\t0.25 % RSD of peak areas from 5 to 100 µl\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003ePressure Range\u003c\/b\u003e\u003cbr\u003e\n\t\t\t\t0 - 60 Mpa\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"features-section\"\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cspan class=\"features-header\"\u003eFeatures\u003c\/span\u003e\n\t\t\t\u003cul\u003e\n\t\t\t\t\u003cli\u003eTransport mechanism uses an X-Z-Theta movement to optimize vial pick-up and return.\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eLeak detection and safe leak handling, low voltages in maintenance areas, error detection and display.\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eEarly maintenance feedback (EMF), electronic records of maintenance and errors.\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eThe autosampler continuous flow-through design ensures that sample loop, needle inside, seat capillary, and the mainpass of the injection valve is always in the flow line.\u003c\/li\u003e\n\t\t\t\u003c\/ul\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/1329B_-_Marshall_Scientific.jpg?v=1779985203\"\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003eThe Agilent 1260 Infinity I HPLC G1329B Autosampler is designed to offer the well-established flow-through design with variable volume injection and to achieve extremely low carryover, providing increased analysis speed with sensitivity, resolution, and precision. This autosampler features a sample capacity of up to 100 samples. The 1260 Infinity G1329B Autosampler is designed for use with other modules of the Agilent 1200 Infinity Series, 1200 Series, or 1100 Series LC, or with other LC systems if adequate remote control inputs and outputs are available. The autosampler is controlled by the Agilent Instant Pilot or by Agilent control software\u003cbr\u003e\u003cbr\u003eThe G1329B's transport mechanism uses an X-Z-Theta movement to optimize vial pick-up and return. A gripper arm picks up the vials and positions them below the sampling unit. Movement is also monitored by optical sensors and optical encoders to ensure correct operation. The metering device is always flushed after injection to ensure minimum carry-over. The standard analytical head of the metering device provides injection volumes from 0.1 to 100 µl, and can be operated up to 600 bar. For applications that require temperature control, this module can be paired with the Agilent 1290 Infinity Thermostat (G1330B). \u003cbr\u003e\u003cbr\u003eAll of our equipment is fully tested to perform at factory specifications before being shipped.   \u003cbr\u003e\n\t\u003cbr\u003e\n\t\u003cdiv class=\"included-box\"\u003e\n\t\t\u003cspan class=\"included-header\"\u003eINCLUDED:\u003c\/span\u003e\u003cbr\u003eThe Agilent 1260 Infinity I HPLC G1329B Autosampler includes:\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eFirmware Version 07.02 (Can be changed upon request)\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eFront Cover\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003e100 Vial Tray\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eOperator's Guide\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eLab Advisor Documentation\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003ePower Cord\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eFull 180 Day Parts and Labor Warranty\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\n\t\u003ch2\u003eAgilent 1260 Infinity I HPLC G1329B Autosampler Specifications\u003c\/h2\u003e\n\t\u003ctable class=\"MsoTableGrid\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\t\u003ctbody\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd width=\"199\" valign=\"top\" style=\"width: 149.4pt; border-width: 1pt; border-color: windowtext; padding: 0in 5.4pt;\"\u003e\n\t\t\tPressure\n\t\t\u003c\/td\u003e\n\t\t\u003ctd width=\"439\" valign=\"top\" style=\"width: 329.4pt; border-top-width: 1pt; border-right-width: 1pt; border-bottom-width: 1pt; border-top-color: windowtext; border-right-color: windowtext; border-bottom-color: windowtext; border-left: none; padding: 0in 5.4pt;\"\u003e\n\t\t\tOperating range 0 - 60 MPa (0 - 600 bar, 0 - 8850 psi)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd width=\"199\" valign=\"top\" style=\"width: 149.4pt; border-width: 1pt; border-color: windowtext; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\nGLP Features\n\t\t\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd width=\"439\" valign=\"top\" style=\"width: 329.4pt; border-top-width: 1pt; border-right-width: 1pt; border-bottom-width: 1pt; border-top-color: windowtext; border-right-color: windowtext; border-bottom-color: windowtext; border-left: none; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\nEarly maintenance feedback (EMF), electronic records of maintenance\nand errors\n\t\t\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd width=\"199\" valign=\"top\" style=\"width: 149.4pt; border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; border-top: none; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\nCommunications\n\t\t\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd width=\"439\" valign=\"top\" style=\"width: 329.4pt; border-top: none; border-left: none; border-bottom-width: 1pt; border-bottom-color: windowtext; border-right-width: 1pt; border-right-color: windowtext; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\nController-area network (CAN), RS232C, APG-remote standard, optional four external contact closures and BCD vial number output\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd width=\"199\" valign=\"top\" style=\"width: 149.4pt; border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; border-top: none; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\nSafety Features\n\t\t\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd width=\"439\" valign=\"top\" style=\"width: 329.4pt; border-top: none; border-left: none; border-bottom-width: 1pt; border-bottom-color: windowtext; border-right-width: 1pt; border-right-color: windowtext; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\nLeak detection and safe leak handling, low voltages in maintenance\nareas, error detection and display\n\t\t\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd width=\"199\" valign=\"top\" style=\"width: 149.4pt; border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; border-top: none; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\nInjection Range\n\t\t\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd width=\"439\" valign=\"top\" style=\"width: 329.4pt; border-top: none; border-left: none; border-bottom-width: 1pt; border-bottom-color: windowtext; border-right-width: 1pt; border-right-color: windowtext; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\n0.1 – 100 µl in 0.1 µl increments (recommended 1 \n\t\t\t\t\u003cspan style=\"background-color: initial; font-size: 1em;\"\u003eµl increments)\u003c\/span\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\n\t\t\t\tUp to 1500 \n\t\t\t\t\u003cspan style=\"background-color: initial; font-size: 1em;\"\u003eµl with multiple draw (hardware modification required)\u003c\/span\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd width=\"199\" valign=\"top\" style=\"width: 149.4pt; border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; border-top: none; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\nReplicate Injections\n\t\t\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd width=\"439\" valign=\"top\" style=\"width: 329.4pt; border-top: none; border-left: none; border-bottom-width: 1pt; border-bottom-color: windowtext; border-right-width: 1pt; border-right-color: windowtext; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\n1 – 99 from one vial\n\t\t\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd width=\"199\" valign=\"top\" style=\"width: 149.4pt; border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; border-top: none; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\nPrecision\n\t\t\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd width=\"439\" valign=\"top\" style=\"width: 329.4pt; border-top: none; border-left: none; border-bottom-width: 1pt; border-bottom-color: windowtext; border-right-width: 1pt; border-right-color: windowtext; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\nTypically \u0026lt; 0.25 % RSD of peak areas from 5 to 100 µl\n\t\t\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\nTypically \u0026lt; 1 % RSD of peak areas from 1 to 5 µl\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd width=\"199\" valign=\"top\" style=\"width: 149.4pt; border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; border-top: none; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\nMinimum Sample Volume\n\t\t\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd width=\"439\" valign=\"top\" style=\"width: 329.4pt; border-top: none; border-left: none; border-bottom-width: 1pt; border-bottom-color: windowtext; border-right-width: 1pt; border-right-color: windowtext; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\n1 µl from 5 µl sample in 100 µl microvial, or 1 µl from 10 µl sample\nin 300 µl microvial\n\t\t\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd width=\"199\" valign=\"top\" style=\"width: 149.4pt; border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; border-top: none; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\nCarryover\n\t\t\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd width=\"439\" valign=\"top\" style=\"width: 329.4pt; border-top: none; border-left: none; border-bottom-width: 1pt; border-bottom-color: windowtext; border-right-width: 1pt; border-right-color: windowtext; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\nTypically \u0026lt; 0.1 %, \u0026lt; 0.05 % with external needle cleaning\n\t\t\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd width=\"199\" valign=\"top\" style=\"width: 149.4pt; border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; border-top: none; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\nSample Viscosity Range\n\t\t\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd width=\"439\" valign=\"top\" style=\"width: 329.4pt; border-top: none; border-left: none; border-bottom-width: 1pt; border-bottom-color: windowtext; border-right-width: 1pt; border-right-color: windowtext; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\n0.2 – 50 cp\n\t\t\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd width=\"199\" valign=\"top\" style=\"width: 149.4pt; border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; border-top: none; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\n\t\t\t\tMetering Devices\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd width=\"439\" valign=\"top\" style=\"width: 329.4pt; border-top: none; border-left: none; border-bottom-width: 1pt; border-bottom-color: windowtext; border-right-width: 1pt; border-right-color: windowtext; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\n\t\t\t\tMetering pump in high pressure flow path\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd width=\"199\" valign=\"top\" style=\"width: 149.4pt; border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; border-top: none; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\nSample Capacity\n\t\t\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd width=\"439\" valign=\"top\" style=\"width: 329.4pt; border-top: none; border-left: none; border-bottom-width: 1pt; border-bottom-color: windowtext; border-right-width: 1pt; border-right-color: windowtext; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\n100 × 2 ml vials in 1 tray\n\t\t\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\n40 × 2 ml vials in ½ tray\n\t\t\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\n15 × 6 ml vials in ½ tray (Agilent vials only)\n\t\t\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd width=\"199\" valign=\"top\" style=\"width: 149.4pt; border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; border-top: none; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\nInjection Cycle Time\n\t\t\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd width=\"439\" valign=\"top\" style=\"width: 329.4pt; border-top: none; border-left: none; border-bottom-width: 1pt; border-bottom-color: windowtext; border-right-width: 1pt; border-right-color: windowtext; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal;tab-stops:53.05pt\"\u003e\n\t\t\t\t50 seconds for draw speed 200 \n\t\t\t\t\u003cspan style=\"background-color: initial; font-size: 1em;\"\u003eµl\/min, ejection speed 200 \u003c\/span\u003e\u003cspan style=\"background-color: initial; font-size: 1em;\"\u003eµl\/min, injection volume 5 \u003c\/span\u003e\u003cspan style=\"background-color: initial; font-size: 1em;\"\u003eµl\u003c\/span\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd width=\"199\" valign=\"top\" style=\"width: 149.4pt; border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; border-top: none; padding: 0in 5.4pt;\"\u003e\n\t\t\tAmbient Operating Temperature\n\t\t\u003c\/td\u003e\n\t\t\u003ctd width=\"439\" valign=\"top\" style=\"width: 329.4pt; border-top: none; border-left: none; border-bottom-width: 1pt; border-bottom-color: windowtext; border-right-width: 1pt; border-right-color: windowtext; padding: 0in 5.4pt;\"\u003e\n\t\t\t0 to 55°C\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd width=\"199\" valign=\"top\" style=\"width: 149.4pt; border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; border-top: none; padding: 0in 5.4pt;\"\u003e\n\t\t\tDimensions (H x W x D)\n\t\t\u003c\/td\u003e\n\t\t\u003ctd width=\"439\" valign=\"top\" style=\"width: 329.4pt; border-top: none; border-left: none; border-bottom-width: 1pt; border-bottom-color: windowtext; border-right-width: 1pt; border-right-color: windowtext; padding: 0in 5.4pt;\"\u003e\n\t\t\t8 x 13.5 x 17 in (20 x 34.5 x 43.5 cm)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd width=\"199\" valign=\"top\" style=\"width: 149.4pt; border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; border-top: none; padding: 0in 5.4pt;\"\u003e\n\t\t\tWeight\n\t\t\u003c\/td\u003e\n\t\t\u003ctd width=\"439\" valign=\"top\" style=\"width: 329.4pt; border-top: none; border-left: none; border-bottom-width: 1pt; border-bottom-color: windowtext; border-right-width: 1pt; border-right-color: windowtext; padding: 0in 5.4pt;\"\u003e\n\t\t\t32 lb. (14.2 kg)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\t\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cspan class=\"downloads-header\"\u003eDownloads\u003c\/span\u003e\n\u003cdiv class=\"downloads-section\"\u003e\n\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_1260_Infinity_I_G1329B_Autosampler_-_Marshall_Scientific.pdf?v=1779985206\" target=\"blank\"\u003e\n\t\tTechnical Specification Download\n\t\t\u003c\/a\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_1260_Infinity_I_G1329B_Autosampler_Manual_-_Marshall_Scientific.pdf?v=1779985211\" target=\"blank\"\u003e\n\t\tOperator's Manual Download\n\t\t\u003c\/a\u003e\n\t\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"formalquote2\"\u003e\n\t\u003ca class=\"formalquote2link\" href=\"\/formal_quote_a\/2341.htm\"\u003eRequest a Formal Quote\u003c\/a\u003e\n\u003c\/div\u003e","brand":"My Store","offers":[{"title":"Default Title","offer_id":42474463166554,"sku":"AG-1260ALS","price":7795.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-1260ALS-2.jpg?v=1761204932","url":"https:\/\/p2gnpt-0c.myshopify.com\/products\/agilent-1260-infinity-i-hplc-g1329b-autosampler","provider":"Marshall Scientific","version":"1.0","type":"link"}