{"product_id":"agilent-1260-infinity-i-hplc-g1364c-analytical-scale-fraction-collector","title":"Agilent 1260 Infinity I HPLC G1364C Analytical-Scale Fraction Collector","description":"\u003cdiv class=\"productdescriptiontables\"\u003e\n\t\u003ch1\u003eAgilent 1260 Infinity I HPLC G1364C Analytical-Scale Fraction Collector\u003c\/h1\u003e\n\t\u003cbr\u003e\n\tThe Agilent 1260 Infinity I HPLC G1364C Analytical-Scale Fraction Collector is optimized for laboratories performing analytical-scale compound purification of nanogram to milligram quantities with typical flow rates between 0.1 and 10 mL\/min. The module features the full set of collection modes and is compatible with a wide variety of trigger sources. SBS plates and four different tube sizes with various lengths are supported. Equipped with a 3\/2 diverter valve featuring a low internal volume of 15 ul and a quick switching time under 100 ms, it ensures minimal delay and high precision.\u003cbr\u003e\u003cbr\u003eThe Analytical-Scale Fraction Collector's maximum capacity can easily be enhanced by clustering up to three modules simultaneously through a 12-position, 13-port selector valve. Additionally, it offers cooling options when paired with the G1330B for enhanced performance, depending on the collected fraction's volume and ambient conditions. Its delay calibration is managed by a single wavelength absorbance detector operating at 654 nm, ensuring accurate and reliable operation. This model supports multiple trigger modes such as time slices, peak detection, timetable, and manual triggers, making it a flexible choice for a variety of laboratory settings.\u003cbr\u003e\u003cbr\u003eAll of our equipment is fully tested to perform at factory specifications before being shipped.\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"included-box\"\u003e\n\t\t\u003cspan class=\"included-header\"\u003eINCLUDED:\u003c\/span\u003e\u003cbr\u003eThe Agilent 1260 Infinity I HPLC G1364C Analytical-Scale Fraction Collector includes:\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eFirmware Version 07.02 (Can be changed upon request)\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eMTP Tray\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eFront Cover\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eDelay Volume Detection and Lab Advisor Report\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eOperator's Guide\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eLan Cable \/ Power Cord\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eFull 180 Day Parts and Labor Warranty\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\n\t\u003ch2\u003eAgilent 1260 Infinity I HPLC G1364C Analytical-Scale Fraction Collector Specifications\u003c\/h2\u003e\n\t\u003ctable\u003e\n\t\u003ctbody\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tDelay Volume (in ul)\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tFraction collector inlet to diverter valve: ~50 (typical, depends on length of the tubing)\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tDiverter valve: ~15\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tDiverter valve to needle: ~10\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tNeedle: ~4\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tMaximum System Flow\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t10 mL\/min (depending on viscosity and generated back pressure, max. 6 bar at the diverter valve). The analytical scale fraction collector can be modified for flow rates \u0026gt; 10 ml\/min\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tMaximum Collection Volume\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t~20 mL with 48 mm tubes\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t~30 mL with 75 mm tubes\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tMaximum Capacity\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t3 fraction collectors in parallel plus one recovery fraction collector connected via 12-Position, 13-Port Selector valve (PN G1160A)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tCooling\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tOptional (with additional G1330B), performance depending on ambient conditions and the volume of collected fractions\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tTrigger Modes\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tTime slices\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tPeak (threshold, up- \/ downslope)\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tTimetable (combination of time intervals and peak)\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tManual trigger (supported only with Agilent Instant Pilot G4208A)\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tTrigger Sources\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tAgilent 1260 Infinity DAD\/MWD detectors (G1315C,D; G4212B\/ G1365 C,D), the Agilent 1260 Infinity Fluorescence Detector (G1321A) and the Agilent G1946C\/D, G1956A\/B LC-MSD are fully supported\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tOperating Modes\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tDiscrete fractions: default mode for all vessels. The flow is diverted to waste, while moving from one vessel position to the next vessel position\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tContinuous flow: optional, available only when using deep well plates. It is possible to move from one well plate position to the next one without diverting the flow into the well plate to waste\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tNeedle into location: Needle pushes into the vessel as deep as specified, for the use with capped vials and test tubes and well plates with closing mats\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tDroplet setup mode: The tip of the fraction collector needle will initially move down to the bottom of the well. Then it will slowly move upwards while the fraction is collected. The droplet setup mode enables the fraction collector to collect small fractions without bubbles\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDiverter Valve\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t3\/2 valve, with switching time \u0026lt; 100 ms\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tMaximum Pressure\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t6 bar at the diverter valve during switching\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tPlates\/Trays\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t4 x well-plates full tray (MTP)*\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t2 x well-plates std. tray + 10 funnels with external containers* (+ 1 half tray)\u003c\/p\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t2 × well-plates std. tray (MTP) + 10 × 2 ml vials* (+ 1 half tray)\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t100 x 2 ml in std. tray (+ 1 half tray)*\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t3 x 40 x 2 ml in half tray*\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t3 x 40 funnels in half tray\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t3 x 15 x 6 ml in half tray*\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tFull tray with 40 test tubes (30 mm OD, max. height 48 mm, ~20 ml vol.)\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tFull tray with 60 test tubes (25 mm OD, max. height 48 mm\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tFull tray with 126 test tubes (16 mm OD, max. height 48 mm)\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tFull tray with 215 test tubes (12 mm OD, max. height 48 mm)\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tMaximum Tube Height\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t48 mm with long needle assembly G1367-87200\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t75 mm with short needle assembly G1364-87202\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDelay Calibration Sensor\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tSingle wavelength absorbance detector working at 654 nm, consisting of a LED and a photo diode\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDiverter Valve\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t3\/2 Diverter Valve with low internal volume (15 ul), switching time \u0026lt; 100 ms, maximum operating pressure 6 bar\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDimensions (H x W x D)\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t8 x 13.5 x 17 in. (20 x 34.5 x 44 cm)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tWeight\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t29.8 lb. (13.5 kg)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tElectrical Requirements\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t100-240V, 50\/60Hz, 200VA\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\t\u003c\/table\u003e\n\t\u003cspan class=\"downloads-header\"\u003eDownloads\u003c\/span\u003e\n\t\u003cdiv class=\"downloads-section\"\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_1260_Infinity_I_HPLC_G1364C_Analytical-Scale_Fraction_Collector_-_Marshall_Scientific.pdf?v=1779985230\" target=\"blank\"\u003e\n\t\t\tTechnical Specification Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_1260_Infinity_II_HPLC_G1364F_Analytical-Scale_Fraction_Collector_Manual_-_Marshall_Scientific.pdf?v=1779985234\" target=\"blank\"\u003e\n\t\t\tOperator's Manual Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"formalquote2\"\u003e\n\t\t\u003ca class=\"formalquote2link\" href=\"\/formal_quote_a\/2809.htm\" target=\"blank\"\u003eRequest a Formal Quote\u003c\/a\u003e\n\t\u003c\/div\u003e\n\u003c\/div\u003e","brand":"My Store","offers":[{"title":"Default Title","offer_id":42474461069402,"sku":"AG-126064C","price":7495.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-126064C-2.jpg?v=1761204905","url":"https:\/\/p2gnpt-0c.myshopify.com\/products\/agilent-1260-infinity-i-hplc-g1364c-analytical-scale-fraction-collector","provider":"Marshall Scientific","version":"1.0","type":"link"}