{"product_id":"agilent-1260-infinity-i-hplc-g1367e-high-performance-autosampler","title":"Agilent 1260 Infinity I HPLC G1367E High Performance Autosampler","description":"\u003cdiv class=\"productdescriptiontables\"\u003e\n\t\u003ch1\u003eAgilent 1260 Infinity I HPLC G1367E High Performance Autosampler\u003c\/h1\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-section\"\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eInjection Range\u003c\/b\u003e\u003cbr\u003e\t\n0.1 – 100 µL in 0.1 µL\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eInjection Precision\u003c\/b\u003e\u003cbr\u003e\n\t\t\t\t\u0026lt; 0.25 % from 5 – 40 µL\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003ePressure Range\u003c\/b\u003e\u003cbr\u003e\n\t\t\t\tOperating range 0 - 60 MPa (0 - 600 bar, 0 - 8700 psi)\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"features-section\"\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cspan class=\"features-header\"\u003eFeatures\u003c\/span\u003e\n\t\t\t\u003cul\u003e\n\t\t\t\t\u003cli\u003eHigh-speed X-Z-theta robotic arm for fast and accurate sample positioning\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eFlow-through design minimizes carryover and supports high sample throughput\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eOverlapped injection mode increases productivity in high-throughput environments\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eCompatible with a wide range of sample containers, including vials, well plates, Eppendorf tubes, and microvial trays\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eFast injection cycle time of under 21 seconds for improved efficiency\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eNeedle flush station with peristaltic pump reduces carryover for sensitive analyses\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eBuilt-in leak detection and safe waste management for enhanced operational safety\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eEarly maintenance feedback (EMF) system tracks component usage and service needs\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eAdvanced diagnostics and error detection for reliable performance\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eOptional temperature control via external thermostat module for sample stability\u003c\/li\u003e\n\t\t\t\u003c\/ul\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-1260ALSE_377be630-79c0-4b63-a991-8f02250e6bc8.jpg?v=1779985255\"\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003eThe Agilent 1260 Infinity I HPLC G1367E High Performance Autosampler is designed for fast, precise, and flexible sample injection in high-throughput HPLC workflows. Supporting pressures up to 600 bar, it seamlessly integrates with modern narrow-bore columns and binary LC systems to boost productivity. With an injection range from 0.1 to 100 µL and exceptional precision even at low volumes, this autosampler enables reliable analysis across a wide range of sample types and volumes.\n\t\u003cbr\u003e\u003cbr\u003e\n\tEngineered with a robust X-Z-theta robotic arm, high-speed injection valve, and low carryover flow-through design, the G1367E delivers high repeatability and minimal downtime. Built-in early maintenance feedback (EMF), leak detection, and advanced diagnostics enhance operational reliability. Sample capacity is highly flexible, accommodating well plates, vials, Eppendorf tubes, and microvial trays, with fast injection cycles of under 21 seconds. A needle flush station minimizes carryover, while optional thermostatted modules ensure precise vial\/plate temperature control for sensitive workflows. This high-performance autosampler is ideal for demanding labs requiring efficiency, precision, and scalability.\u003cbr\u003e\u003cbr\u003eAll of our equipment is fully tested to perform at factory specifications before being shipped.   \u003cbr\u003e\n\t\u003cbr\u003e\n\t\u003cdiv class=\"included-box\"\u003e\n\t\t\u003cspan class=\"included-header\"\u003eINCLUDED:\u003c\/span\u003e\u003cbr\u003eThe Agilent 1260 Infinity I HPLC G1367E High Performance Autosampler includes:\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eFirmware Version 07.02 (Can be changed upon request)\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eFront Cover\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eMTP Tray\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eOperator's Guide\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eLab Advisor Documentation\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003ePower Cord\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eFull 180 Day Parts and Labor Warranty\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\n\t\u003ch2\u003eAgilent 1260 Infinity I HPLC G1367E High Performance Autosampler Specifications\u003c\/h2\u003e\n\t\u003ctable\u003e\n\t\u003ctbody\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tPressure\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tOperating range 0 - 60 MPa (0 - 600 bar, 0 - 8700 psi)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tGLP Features\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tEarly maintenance feedback (EMF), electronic records of maintenance and errors\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tCommunications\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\nController-area network (CAN), RS232C, APG-remote standard, optional four external contact closures and BCD vial number output\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\nSafety Features\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\nLeak detection and safe leak handling, low voltages in maintenance areas, error detection and display\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tInjection Range\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t0.1 – 100 µL in 0.1 µL increments (recommended 1 µl increments)\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tUp to 40 µL with reduced injection volume kit (hardware modification required)\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tUp to 1500 µl with multiple draw (hardware modification required)\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tPrecision\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t\u0026lt; 0.25 % from 5 – 40 µL\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t\u0026lt; 0.5 % from 2 – 5 µL\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t\u0026lt; 0.7 % from 1 – 2 µL\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t\u0026lt; 1.5 % from 0.5 – 1 µL\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tCarryover\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tTypically \u0026lt; 0.004%\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tSample Viscosity Range\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t0.2 – 5 cp\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tMetering Devices\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tMetering pump in high pressure flow path\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tSample Capacity\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t2 x well plates (MTP) + 10 x 2 ml vials\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t108 x 2 ml vials in 2 x 54 vial plate plus 10 additional 2 ml vials\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t30 x 6 ml vials in 2 x 15 vial plate\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t100 Micro vial tray\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t54 Eppendorf tubes (0.5\/1.5\/2 ml) in 2 x 27 Eppendorf tube plate\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tInjection Cycle Time\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tTypically \u0026lt; 21 s using default conditions and injections volume of 5 µL\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tAmbient Operating Temperature\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t4 to 55°C\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDimensions (H x W x D)\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t8 x 13.5 x 17 in (20 x 34.5 x 43.5 cm)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tWeight\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t35 lb. (15.5 kg)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\t\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cspan class=\"downloads-header\"\u003eDownloads\u003c\/span\u003e\n\u003cdiv class=\"downloads-section\"\u003e\n\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_1260_Infinity_I_HPLC_G1367E_High_Performance_Autosampler_-_Marshall_Scientific.pdf?v=1779985259\" target=\"blank\"\u003e\n\t\tTechnical Specification Download\n\t\t\u003c\/a\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_1260_Infinity_I_HPLC_G1367E_High_Performance_Autosampler_Manual_-_Marshall_Scientific.pdf?v=1779985264\" target=\"blank\"\u003e\n\t\tOperator's Manual Download\n\t\t\u003c\/a\u003e\n\t\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"formalquote2\"\u003e\n\t\u003ca class=\"formalquote2link\" href=\"\/formal_quote_a\/2906.htm\"\u003eRequest a Formal Quote\u003c\/a\u003e\n\u003c\/div\u003e","brand":"My Store","offers":[{"title":"Default Title","offer_id":42474465919066,"sku":"AG-1260ALSE","price":7995.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-1260ALSE-2.jpg?v=1761204962","url":"https:\/\/p2gnpt-0c.myshopify.com\/products\/agilent-1260-infinity-i-hplc-g1367e-high-performance-autosampler","provider":"Marshall Scientific","version":"1.0","type":"link"}