{"product_id":"agilent-1260-infinity-ii-hplc-g7129a-vialsampler","title":"Agilent 1260 Infinity II HPLC G7129A Vialsampler","description":"\u003cdiv class=\"productdescriptiontables\"\u003e\n\t\u003ch1\u003eAgilent 1260 Infinity II HPLC G7129A Vialsampler\n\t\u003c\/h1\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-section\"\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eInjection Range\u003c\/b\u003e\u003cbr\u003e0.1 – 100 uL in 0.1 uL increments with 100 uL up to 60 MPa\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003ePrecision\u003c\/b\u003e\u003cbr\u003e\n\t\t\t\t\u0026lt; 0.25 % RSD of peak areas from 5 uL to 100 uL\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003ePressure Range\u003c\/b\u003e\u003cbr\u003e\n\t\t\t\t0 – 60 MPa (0 – 600 bar, 0 – 8702 psi)\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"features-section\"\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cspan class=\"features-header\"\u003eFeatures\u003c\/span\u003e\n\t\t\t\u003cul\u003e\n\t\t\t\t\u003cli\u003eHigh-capacity autosampler designed for routine LC workflows\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eSupports reliable and reproducible sample introduction\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eDual vial drawer design accommodates large sample sets\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eRobotic gripper arm ensures precise and flexible vial handling\u003c\/li\u003e\n\t\t\t\t\u003cli\u003e\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003eNeedle wash reduces carryover between injections\u003c\/span\u003e\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eOverlapped injection capability improves sample throughput\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eCustomizable injection programs support advanced sample handling steps\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eLow internal volume minimizes contribution to system dispersion\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eCompatible with Agilent InfinityLab LC systems and standard control software\u003c\/li\u003e\n\t\t\t\u003c\/ul\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-1260VS.jpg?v=1779985444\"\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\tThe Agilent 1260 Infinity II HPLC G7129A Vialsampler is a high-capacity autosampler designed for reliable, routine liquid chromatography in pharmaceutical quality control, environmental analysis, and food testing applications. Built for ease of use and consistent operation, the G7129A supports precise and reproducible sample handling. The vialsampler accommodates up to 132 sample vials using dual vial drawers and employs a robotic gripper arm driven by stepper motors to ensure accurate and flexible vial transport. Its automated needle wash function rinses the outside of the needle to help minimize carryover between injections. Overlapped injection capability and customizable injection programs support efficient sample handling and improved throughput.\n\t\u003cbr\u003e\u003cbr\u003e\n\tDesigned for integration within Agilent InfinityLab LC systems, the G7129A features a low internal volume that minimizes contribution to overall system dispersion, helping preserve chromatographic performance and reproducibility. For temperature-sensitive applications, optional thermostatted modules support precise temperature control to maintain sample integrity throughout analysis.\u003cbr\u003e\u003cbr\u003eAll of our equipment is fully tested to perform at factory specifications before being shipped.   \n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"included-box\"\u003e\n\t\t\u003cspan class=\"included-header\"\u003eINCLUDED:\u003c\/span\u003e\u003cbr\u003eThe Agilent 1260 Infinity II HPLC G7129A Vialsampler includes:\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eFirmware Version 07.02 (Can be changed upon request)\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eFront Cover\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eTwo 66 x 2 mL Vial Trays\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003ePower Cord\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eOperator's Manual\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eLab Advisor Documentation\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eFull 180 Day Parts and Labor Warranty\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\n\t\u003ch2\u003eAgilent 1260 Infinity II HPLC G7129A Vialsampler Specifications\u003c\/h2\u003e\n\t\u003ctable\u003e\n\t\u003ctbody\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tPressure\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t0 – 60 MPa (0 – 600 bar, 0 – 8702 psi)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tGLP Features\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tEarly maintenance feedback (EMF) for continuous tracking of instrument usage with user-settable limits and feedback messages. Electronic records of maintenance and errors\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tCommunications\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tController Area Network (CAN), Local Area Network (LAN) \n\t\t\t\u003cbr\u003eERI: ready, start, stop and shut-down signals\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tSafety Features\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tLeak detection, safe leak handling, leak output signal for shutdown of pumping system, and low voltages in major maintenance areas\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tInjection Range\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t0.1 – 100 uL in 0.1 uL increments with 100 uL up to 60 MPa\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tPrecision\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u0026lt; 0.25 % RSD of peak areas from 5 uL to 100 uL\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tCarryover\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tTypically \u0026lt; 0.004% with needle wash\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tSample Viscosity Range\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t0.2 to 5 cP\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tSample Capacity\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t132 x 2 ml vials\n\t\t\t\u003cbr\u003e100 x 2 mL vials\u003cbr\u003e36 x 6 mL vials\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tInjection Cycle Time\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tTypically 18 s for draw speed 200 uL\/min and injections volume of 1 uL\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tAmbient Operating Temperature\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t4 to 55°C\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDimensions (W x D x H)\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t15.6 x 18.4 x 12.8 in. (39.6 x 46.8 x 32 cm)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tWeight\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t41.9 lb. (19 kg)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tElectrical Requirements\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t100-240V, 50\/60Hz, 350VA\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\t\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cspan class=\"downloads-header\"\u003eDownloads\u003c\/span\u003e\n\u003cdiv class=\"downloads-section\"\u003e\n\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_1260_Infinity_II_HPLC_G7129A_Vialsampler_-_Marshall_Scientific.pdf?v=1779985448\" target=\"blank\"\u003e\n\t\tTechnical Specification Download\n\t\t\u003c\/a\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_1260_Infinity_II_HPLC_G7129A_Vialsampler_Manual_-_Marshall_Scientific.pdf?v=1779985455\" target=\"blank\"\u003e\n\t\tOperator's Manual Download\n\t\t\u003c\/a\u003e\n\t\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"formalquote2\"\u003e\n\t\u003ca class=\"formalquote2link\" href=\"\/formal_quote_a\/3091.htm\" target=\"blank\"\u003eRequest a Formal Quote\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Marshall scientific","offers":[{"title":"Default Title","offer_id":43428356685914,"sku":"AG-1260VS","price":13125.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-1260VS-2T.jpg?v=1779980237","url":"https:\/\/p2gnpt-0c.myshopify.com\/products\/agilent-1260-infinity-ii-hplc-g7129a-vialsampler","provider":"Marshall Scientific","version":"1.0","type":"link"}