{"product_id":"agilent-6230a-accurate-mass-tof-mass-spectrometer-w-1200-lc-system","title":"Agilent 6230A Accurate-Mass TOF Mass Spectrometer w\/ 1200 LC System","description":"\u003cdiv class=\"productdescriptiontables\"\u003e\n\u003ch1\u003eAgilent 6230A Accurate-Mass TOF Mass Spectrometer w\/ 1200 LC System\u003c\/h1\u003e\n\u003cbr\u003e\u003cbr\u003e\n\u003cdiv class=\"highlights-divider\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"highlights-section\"\u003e\n\u003cdiv class=\"inner-highlight-div\"\u003e\n\u003cp class=\"inner-highlight\"\u003e\u003cb\u003eMass Range\u003c\/b\u003e\u003cbr\u003em\/z 25 to 20,000\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"inner-highlight-div\"\u003e\n\u003cp class=\"inner-highlight\"\u003e\u003cb\u003eMass Accuracy\u003c\/b\u003e\u003cbr\u003e\u0026lt; 1 ppm (measured at m\/z 609.2807)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"inner-highlight-div\"\u003e\n\u003cp class=\"inner-highlight\"\u003e\u003cb\u003eSpectral Acquisition Rate\u003c\/b\u003e\u003cbr\u003e30 spectra\/second (from m\/z 100 to 3,200)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"highlights-divider\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"features-section\"\u003e\n\u003cdiv class=\"features-side\"\u003e\n\u003cspan class=\"features-header\"\u003eFeatures\u003c\/span\u003e\n\u003cul\u003e\n\u003cli\u003eOrthogonal acceleration TOF design for enhanced resolution and minimized entrance velocity effects\u003c\/li\u003e\n\u003cli\u003eAgilent Jet Stream ESI technology for increased ionization efficiency and low picogram sensitivity\u003c\/li\u003e\n\u003cli\u003eDynamic range spanning five orders of magnitude for detecting trace-level compounds in complex matrices\u003c\/li\u003e\n\u003cli\u003eAutomated tuning and calibration for consistent performance and reduced user intervention\u003c\/li\u003e\n\u003cli\u003eReal-time internal reference mass correction with built-in calibrant delivery system\u003c\/li\u003e\n\u003cli\u003eResolving power of 22,000 FWHM for separating closely related compounds\u003c\/li\u003e\n\u003cli\u003ePolarity switching in under 1 second for versatile positive and negative ion analysis\u003c\/li\u003e\n\u003cli\u003eSingle-point data control for seamless integration with HPLC systems and error management\u003c\/li\u003e\n\u003cli\u003eOptional in-source dissociation for untargeted screening and enhanced fragmentation data\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"features-side\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-6230.jpg?v=1779985757\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cbr\u003eThe Agilent 6230A Accurate-Mass TOF Mass Spectrometer w\/ 1200 LC System is a high-performance time-of-flight (TOF) system designed to provide precise, high-resolution mass measurements for a wide range of applications, including drug discovery, metabolomics, and environmental analysis. Utilizing orthogonal acceleration (oa-TOF) technology, this instrument directs ions perpendicularly to their original trajectory before they enter the flight tube, reducing entrance velocity effects and enhancing resolution. With its ability to capture a full mass spectrum scan up to 20,000 m\/z, the 6230A delivers superior analytical capabilities, allowing for accurate identification of unknown compounds, advanced statistical analysis, and in-depth biomolecule characterization. Equipped with Agilent Jet Stream (AJS) electrospray ionization (ESI) technology, the system enhances ion generation and transmission efficiency through a super-heated sheath gas, significantly increasing sensitivity while maintaining low detection limits. The 6230A ensures high-throughput sample screening with superior mass accuracy, reducing false positives with a precision of better than 1 ppm. This precision is maintained even in demanding workflows, supported by a high spectral acquisition rate of up to 30 spectra per second, enabling robust performance for fast ultra-high-performance liquid chromatography (UHPLC) separations. \u003cbr\u003e\u003cbr\u003eThe Agilent 6230A also offers advanced molecular profiling tools through the intuitive MassHunter software suite, featuring Find by Formula for compound identification based on accurate mass, isotopic abundance, and chemical composition. Additionally, the system supports high-resolution separation of complex mixtures, enabling confident elemental formula determination. With a broad dynamic range of up to five orders of magnitude, this TOF mass spectrometer can detect trace-level analytes even in complex matrices, making it a powerful tool for impurity profiling and advanced biological analysis. Designed for versatility, the 6230A supports multiple ionization sources, including ESI, atmospheric pressure chemical ionization (APCI), atmospheric pressure photoionization (APPI), multimode (ESI and APCI), HPLC-Chip\/MS interface, and AP\/MALDI PDF+ sources. It incorporates a dual-sprayer orthogonal ESI source with a built-in calibrant delivery system, allowing for real-time internal reference mass correction. The system's single-point data control integrates HPLC and TOF operations, automatically stopping sample injections if errors or leaks occur, improving workflow efficiency and reducing operational risks. \u003cbr\u003e\u003cbr\u003eWith a resolving power of 22,000 full width at half maximum (FWHM) and a mass accuracy stability of 2 ppm even with temperature fluctuations, the Agilent 6230A provides consistently high-quality data. The system’s automated tuning and calibration capabilities optimize ion optics and TOF-MS mass axis alignment, ensuring peak performance with minimal user intervention. For laboratories requiring untargeted screening, the system offers optional in-source dissociation for fragmentation data, further expanding its analytical capabilities. Built to streamline laboratory operations, the Agilent 6230A features MassHunter software, simplifying workflows and minimizing administrative tasks while enabling efficient, expert-level analysis without the need for extensive LC\/MS expertise. Whether analyzing monoclonal antibodies, glycoforms, truncations, or other biologic compounds, the Agilent 6230A provides unparalleled accuracy, resolution, and sensitivity, making it an essential instrument for laboratories seeking cutting-edge mass spectrometry performance. \u003cbr\u003e\u003cbr\u003e\u003cb\u003eThis Agilent LC\/MS system was recertified and calibrated by a factory trained engineer and is ready to ship on demand. This system comes with everything needed for easy installation and setup. All of our equipment is fully tested to perform at factory specifications before being shipped.\u003c\/b\u003e \u003cbr\u003e\u003cbr\u003e\n\u003cdiv class=\"included-box\"\u003e\n\u003cspan class=\"included-header\"\u003eINCLUDED:\u003c\/span\u003e\u003cbr\u003eThe Agilent 6230A Accurate-Mass TOF Mass Spectrometer w\/ 1200 LC System includes:\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eAgilent 6230A Single Quadrupole Mass Spectrometer\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eAgilent MS40+ Rotary Vane Vacuum Pump\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eAgilent G1958B Jet Stream Electrospray Ionization Source\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eG1312B Binary Pump (G1311A Quaternary Pump available, please inquire)\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eG1329A Autosampler\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eG1330B ALS Thermostat\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eG1316A TCC\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eG1379B Degasser\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eG1315C DAD Detector\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eWindows 10 Professional 64-Bit Data Station with Flatscreen Monitor\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eAgilent MassHunter B.09.01 Acquisition and Data Analysis Software Installed\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eAgilent MassHunter BioConfirm Software Installed\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eAll Power Cords\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eCan\/Crossover Cables\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eAgilent Lan Interface Card Built-In\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eSolvent Tubing\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eCapillaries\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eAgilent 4 Peak Test w\/ Lab Advisor Diagnostics Report \u0026amp; Mass Spec Tuning Report\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eFull 180 Day Parts and Labor Warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\n\u003cdiv class=\"agilent-tests\"\u003e\n\u003cspan class=\"agilent-tests-title\"\u003eBelow is a List of Diagnostic Tests Performed On This LC System\u003c\/span\u003e\u003cbr\u003e\u003cspan class=\"agilent-tests-header\"\u003eG1315C Diode Array Detector Diagnostic Tests:\u003c\/span\u003e\n\u003cul\u003e\n\u003cli\u003eFilter Test: The test moves the filter into the light path and measures the relative absorbance in the filter position.\u003c\/li\u003e\n\u003cli\u003eDark Current Test: The test measures the dark current from the detector optic.\u003c\/li\u003e\n\u003cli\u003eHolmium Oxide Test: The test measures the Holmium spectrum from the built-in Holmium filter. The spectrum is evaluated for peaks at different wavelengths.\u003c\/li\u003e\n\u003cli\u003eLamp Intensity Test: The test verifies functionality of the UV lamp at various wavelengths.\u003c\/li\u003e\n\u003cli\u003eWavelength Intensity Test: The test confirms the accuracy of wavelengths measured.\u003c\/li\u003e\n\u003cli\u003eBaseline Noise Test: The test measures the amount of baseline noise drift identified by the detector.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cspan class=\"agilent-tests-header\"\u003eG1312B Binary Pump Diagnostic Tests:\u003c\/span\u003e\n\u003cul\u003e\n\u003cli\u003ePressure Test: The pressure test is a quick, built-in test designed to demonstrate the pressure tightness (up to 400 bar) of the system.\u003c\/li\u003e\n\u003cli\u003eLeak Test: The leak test is a built-in troubleshooting designed to demonstrate the leak-tightness of the pump.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cspan class=\"agilent-tests-header\"\u003eG1316A Column Compartment Diagnostic Tests:\u003c\/span\u003e\n\u003cul\u003e\n\u003cli\u003eThermostat Test: Evaluates the cooling and heating performance of the two Peltier elements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cspan class=\"agilent-tests-header\"\u003eG1329A Autosampler Diagnostic Tests:\u003c\/span\u003e\n\u003cul\u003e\n\u003cli\u003eInjector Steps: Performs each movement of the sampling sequence under manual control. This is useful for confirming autosampler functionality.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cspan class=\"agilent-tests-header\"\u003eSystem Tests:\u003c\/span\u003e\n\u003cul\u003e\n\u003cli\u003e4 Peak Test (Isocratic Standard): Standard test published by Agilent to confirm complete functionality of the 1200 LC System.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\u003cbr\u003e\n\u003ch2\u003eAgilent 6230A Accurate-Mass TOF Mass Spectrometer Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMS Sensitivity with AJS (Included)\u003c\/td\u003e\n\u003ctd\u003eSignal-to-noise ratio \u0026gt; 50:1, Noise = 1 × RMS (1 pg reserpine injected on-column, measured at m\/z 609.2807)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMS Sensitivity with ESI (Option 200)\u003c\/td\u003e\n\u003ctd\u003eSignal-to-noise ratio \u0026gt; 10:1, Noise = 1 × RMS (1 pg reserpine injected on-column, measured at m\/z 609.2807)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMass Resolving Power\u003c\/td\u003e\n\u003ctd\u003e22,000 FWHM (measured at m\/z 1,522 after automatic tuning procedure)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMass Accuracy - MS Mode\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 1 ppm (measured at m\/z 609.2807 using an internal reference mass)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpectral Acquisition Rate - MS Mode\u003c\/td\u003e\n\u003ctd\u003e30 spectra\/second (spectra acquisition from m\/z 100 to 3,200)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDynamic Range\u003c\/td\u003e\n\u003ctd\u003eUp to 5 decades (in-scan dynamic range on co-eluting components)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMass Range\u003c\/td\u003e\n\u003ctd\u003em\/z 25 to 20,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePolarity Switching\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 1 sec (pos\/neg switching)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMass Accuracy Temperature Stability - MS Mode\u003c\/td\u003e\n\u003ctd\u003eMaintain 2 ppm mass accuracy within 2°C drift per hour (temperature: 15°C to 35°C (59°F to 95°F) at constant temperature while setting autotune at 25°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle Point of Control\u003c\/td\u003e\n\u003ctd\u003eSingle point data system method capability with full control for HPLC system and TOF, stopping sample injection if errors or leaks occur\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIonization sources\u003c\/td\u003e\n\u003ctd\u003eElectrospray (ESI), Atmospheric pressure chemical ionization (APCI), Atmospheric pressure photoionization (APPI), Multimode source (ESI and APCI), HPLC-Chip\/MS interface, AP\/MALDI PDF+ source\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransparent Introduction of Reference Masses\u003c\/td\u003e\n\u003ctd\u003eDual-sprayer orthogonal ESI source, built-in calibrant delivery system, real-time internal reference mass correction for MS operation and heated sources\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutotune\u003c\/td\u003e\n\u003ctd\u003eAutomated optimization of ion optics and full TOF MS mass axis calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Mining Tools\u003c\/td\u003e\n\u003ctd\u003eOne-button extraction of compound-specific spectral and chromatographic information using find compounds algorithms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMolecular Profiling Tools\u003c\/td\u003e\n\u003ctd\u003eMeasurement of molecular features from LC\/MS analyses (MassHunter), differential expression analysis with optional MassHunter Mass Profiler\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound Emission\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 70 db\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (L x W x H)\u003c\/td\u003e\n\u003ctd\u003e32.7 x 28.7 x 52.4 in. (83 x 73 x 133 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e260 lb. (117.9 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Requirements\u003c\/td\u003e\n\u003ctd\u003e200-220VAC, 50\/60Hz, 15A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003cdiv class=\"show-hidden-table\"\u003eClick Here to View Specifications for the Agilent 1200 LC System\u003c\/div\u003e\n\u003cbr\u003e\n\u003cdiv class=\"hidden-table\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDAD Detector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection Type\u003c\/td\u003e\n\u003ctd\u003e1024-element photodiode array\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Source\u003c\/td\u003e\n\u003ctd\u003eDeuterium and tungsten lamps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength Range\u003c\/td\u003e\n\u003ctd\u003e190 - 950 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort Term Noise (ASTM) Single and Multi-Wavelength\u003c\/td\u003e\n\u003ctd\u003e± 0.8 × 10 \u003csup\u003e-5\u003c\/sup\u003e AU at 254 and 750 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrift\u003c\/td\u003e\n\u003ctd\u003e0.9 × 10 \u003csup\u003e-3\u003c\/sup\u003e AU\/hr at 254 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinear Absorbance Range\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 2.0 AU (upper limit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength Accuracy\u003c\/td\u003e\n\u003ctd\u003e± 1 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength Bunching\u003c\/td\u003e\n\u003ctd\u003e1 - 400 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlit Width\u003c\/td\u003e\n\u003ctd\u003e1, 2, 4, 8, 16 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiode Width\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 1 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow Cells\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eStandard: 13 µL volume, 10 mm cell path length and 120 bar (1740 psi) pressure maximum\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBinary Pump\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHydraulic System\u003c\/td\u003e\n\u003ctd\u003eTwo dual piston in series pumps with proprietary servo-controlled variable stroke drive, floating piston design and active inlet valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSetable Flow Range\u003c\/td\u003e\n\u003ctd\u003e0.001 – 5 ml\/min, in 0.001 ml\/min increments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow Range\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0.1 - 5.0 mL\/min\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow Precision\u003c\/td\u003e\n\u003ctd\u003e≤ 0.07% RSD or ≤ 0.02 min SD, whatever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow Accuracy\u003c\/td\u003e\n\u003ctd\u003e± 1% or 10 µl\/min, what ever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure Operating Range\u003c\/td\u003e\n\u003ctd\u003eOperating range 0 to 600 bar (0 – 7800 psi) up to 5 ml\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure Pulsation\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 2 % amplitude (typically \u0026lt; 1 %), at 1 ml\/min isopropanol, at all pressures \u0026gt; 1 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressibility Compensation\u003c\/td\u003e\n\u003ctd\u003eUser-selectable, based on mobile phase compressibility\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended pH Range\u003c\/td\u003e\n\u003ctd\u003e1.0 - 12.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGradient Formation\u003c\/td\u003e\n\u003ctd\u003eHigh-pressure binary mixing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDelay Volume\u003c\/td\u003e\n\u003ctd\u003e600 to 800 µl, dependent on back pressure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eComposition Range\u003c\/td\u003e\n\u003ctd\u003e0 to 100% (1 to 99% or 5 µl\/min per channel, whatever is greater is recommended)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eComposition Precision\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.15% RSD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eComposition Accuracy\u003c\/td\u003e\n\u003ctd\u003e± 0.35% absolute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAutosampler\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInjection Range\u003c\/td\u003e\n\u003ctd\u003e0.1 - 100 µl in 0.1 µl increments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrecision\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u0026lt; 0.25 % RSD of peak areas from 5 to 100 µl\u003c\/p\u003e\n\u003cp\u003e\u0026lt; 1 % RSD of peak areas from 1 to 5 µl\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure Range\u003c\/td\u003e\n\u003ctd\u003eOperating range 0 - 60 MPa (0 - 600 bar, 0 - 8850 psi)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample Viscosity Range\u003c\/td\u003e\n\u003ctd\u003e0.2 to 50 cp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample Capacity\u003c\/td\u003e\n\u003ctd\u003e100 × 2 mL vials in 1 tray \u003cbr\u003e40 × 2 mL vials in ½ tray\u003cbr\u003e15 × 6 mL vials in ½ tray (Agilent vials only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInjection Cycle Time\u003c\/td\u003e\n\u003ctd\u003e50 s for draw speed 200 µL\/min, ejection speed 200 µL\/min, injection volume 5 µL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarryover\u003c\/td\u003e\n\u003ctd\u003eTypically \u0026lt; 0.1 %, \u0026lt; 0.05 % with external needle cleaning\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eALS Thermostat\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e4°C to 40°C in 1°C increments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy at Ambient Temperatures \u0026lt; 25°C and Humidity \u0026lt; 50%\u003c\/td\u003e\n\u003ctd\u003e-1°C to +4°C at a setpoint of 4°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy at Ambient Temperatures \u0026gt; 25°C and Humidity \u0026gt; 50%\u003c\/td\u003e\n\u003ctd\u003e-1°C to +5°C at a setpoint of 4°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eColumn Compartment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003eAmbient -10°C to 80°C at flow rates up to 5 mL\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Stability\u003c\/td\u003e\n\u003ctd\u003e± 0.15 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e± 0.8°C (± 0.5°C with calibration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColumn Capacity\u003c\/td\u003e\n\u003ctd\u003eThree 30 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarm-Up\/Cool-Down Time\u003c\/td\u003e\n\u003ctd\u003e5 minutes from ambient to 40°C \u003cbr\u003e10 minutes from 40°C to 20°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDead Volume\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e3 µl left heat exchanger\u003c\/p\u003e\n\u003cp\u003e6 µl right heat exchanger\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDegasser\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Solvent Channels\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Flow Rate\u003c\/td\u003e\n\u003ctd\u003e0 - 10 mL\/min per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Volume Per Channel\u003c\/td\u003e\n\u003ctd\u003eTypically 12 ml per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaterials in Contact with Solvent\u003c\/td\u003e\n\u003ctd\u003ePTFE, PEEK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e1 - 14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\u003cbr\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" width=\"623\"\u003e\n\u003cp style=\"text-align: center;\"\u003eComputer Specifications\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eModel\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eDell Optiplex 7010 Desktop PC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eProcessor\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIntel Core i5-6500 Processor 3.2GHz\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRAM\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e16GB\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eHard Drive\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e250GB Internal SSD\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOperating System\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eWindows 10 Professional, 64bit\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cspan class=\"downloads-header\"\u003eDownloads\u003c\/span\u003e\n\u003cdiv class=\"downloads-section\"\u003e\n\u003cdiv class=\"pdf-button\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_6230A_Accurate-Mass_TOF_Mass_Spectrometer_-_Marshall_Scientific.pdf?v=1779985761\"\u003e Technical Specification Download \u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"pdf-button\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_6230A_Accurate-Mass_TOF_Mass_Spectrometer_Manual_-_Marshall_Scientific.pdf?v=1779985766\"\u003e Operator's Manual Download \u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"pdf-button\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_6200_Series_TOF_Mass_Spectrometers_Site_Preparation_Guide_-_Marshall_Scientific.pdf?v=1779985769\"\u003e Site Prep Guide Download \u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"formalquote2\"\u003e\u003ca class=\"formalquote2link\" href=\"\/formal_quote_a\/2951.htm\"\u003eRequest a Formal Quote\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"My Store","offers":[{"title":"Default Title","offer_id":42474494754906,"sku":"AG-6230AMS1200","price":85495.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-6230AMS1200-2T.jpg?v=1780433160","url":"https:\/\/p2gnpt-0c.myshopify.com\/products\/agilent-6230a-accurate-mass-tof-mass-spectrometer-w-1200-lc-system","provider":"Marshall Scientific","version":"1.0","type":"link"}