{"product_id":"agilent-6230a-accurate-mass-tof-mass-spectrometer","title":"Agilent 6230A Accurate-Mass TOF Mass Spectrometer","description":"\u003cdiv class=\"productdescriptiontables\"\u003e\n\t\u003ch1\u003eAgilent 6230A Accurate-Mass TOF Mass Spectrometer\u003c\/h1\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-section\"\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eMass Range\u003c\/b\u003e\u003cbr\u003em\/z 25 to 20,000\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eMass Accuracy\u003c\/b\u003e\u003cbr\u003e\u0026lt; 1 ppm (measured at m\/z 609.2807)\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eSpectral Acquisition Rate\u003c\/b\u003e\u003cbr\u003e30 spectra\/second (from m\/z 100 to 3,200)\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"features-section\"\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cspan class=\"features-header\"\u003eFeatures\u003c\/span\u003e\n\t\t\t\u003cul\u003e\n\t\t\t\t\u003cli\u003eOrthogonal acceleration TOF design for enhanced resolution and minimized entrance velocity effects\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eAgilent Jet Stream ESI technology for increased ionization efficiency and low picogram sensitivity\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eDynamic range spanning five orders of magnitude for detecting trace-level compounds in complex matrices\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eAutomated tuning and calibration for consistent performance and reduced user intervention\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eReal-time internal reference mass correction with built-in calibrant delivery system\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eResolving power of 22,000 FWHM for separating closely related compounds\u003c\/li\u003e\n\t\t\t\t\u003cli\u003ePolarity switching in under 1 second for versatile positive and negative ion analysis\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eSingle-point data control for seamless integration with HPLC systems and error management\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eOptional in-source dissociation for untargeted screening and enhanced fragmentation data\u003c\/li\u003e\n\t\t\t\u003c\/ul\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-6230.jpg?v=1779985757\"\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\n\tThe Agilent 6230A Accurate-Mass TOF Mass Spectrometer is a high-performance time-of-flight (TOF) system designed to provide precise, high-resolution mass measurements for a wide range of applications, including drug discovery, metabolomics, and environmental analysis. Utilizing orthogonal acceleration (oa-TOF) technology, this instrument directs ions perpendicularly to their original trajectory before they enter the flight tube, reducing entrance velocity effects and enhancing resolution. With its ability to capture a full mass spectrum scan up to 20,000 m\/z, the 6230A delivers superior analytical capabilities, allowing for accurate identification of unknown compounds, advanced statistical analysis, and in-depth biomolecule characterization. Equipped with Agilent Jet Stream (AJS) electrospray ionization (ESI) technology, the system enhances ion generation and transmission efficiency through a super-heated sheath gas, significantly increasing sensitivity while maintaining low detection limits. The 6230A ensures high-throughput sample screening with superior mass accuracy, reducing false positives with a precision of better than 1 ppm. This precision is maintained even in demanding workflows, supported by a high spectral acquisition rate of up to 30 spectra per second, enabling robust performance for fast ultra-high-performance liquid chromatography (UHPLC) separations.\n\t\u003cbr\u003e\u003cbr\u003e\n\tThe Agilent 6230A also offers advanced molecular profiling tools through the intuitive MassHunter software suite, featuring Find by Formula for compound identification based on accurate mass, isotopic abundance, and chemical composition. Additionally, the system supports high-resolution separation of complex mixtures, enabling confident elemental formula determination. With a broad dynamic range of up to five orders of magnitude, this TOF mass spectrometer can detect trace-level analytes even in complex matrices, making it a powerful tool for impurity profiling and advanced biological analysis. Designed for versatility, the 6230A supports multiple ionization sources, including ESI, atmospheric pressure chemical ionization (APCI), atmospheric pressure photoionization (APPI), multimode (ESI and APCI), HPLC-Chip\/MS interface, and AP\/MALDI PDF+ sources. It incorporates a dual-sprayer orthogonal ESI source with a built-in calibrant delivery system, allowing for real-time internal reference mass correction. The system's single-point data control integrates HPLC and TOF operations, automatically stopping sample injections if errors or leaks occur, improving workflow efficiency and reducing operational risks.\n\t\u003cbr\u003e\u003cbr\u003e\n\tWith a resolving power of 22,000 full width at half maximum (FWHM) and a mass accuracy stability of 2 ppm even with temperature fluctuations, the Agilent 6230A provides consistently high-quality data. The system’s automated tuning and calibration capabilities optimize ion optics and TOF-MS mass axis alignment, ensuring peak performance with minimal user intervention. For laboratories requiring untargeted screening, the system offers optional in-source dissociation for fragmentation data, further expanding its analytical capabilities. Built to streamline laboratory operations, the Agilent 6230A features MassHunter software, simplifying workflows and minimizing administrative tasks while enabling efficient, expert-level analysis without the need for extensive LC\/MS expertise. Whether analyzing monoclonal antibodies, glycoforms, truncations, or other biologic compounds, the Agilent 6230A provides unparalleled accuracy, resolution, and sensitivity, making it an essential instrument for laboratories seeking cutting-edge mass spectrometry performance.\n\t\u003cbr\u003e\u003cbr\u003e\u003cb\u003eThis Agilent MS system was recertified and calibrated by a factory trained engineer and is ready to ship on demand. This system comes with everything needed for easy installation and setup. All of our equipment is fully tested to perform at factory specifications before being shipped.\u003c\/b\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"included-box\"\u003e\n\t\t\u003cspan class=\"included-header\"\u003eINCLUDED:\u003c\/span\u003e\u003cbr\u003eThe Agilent 6230A Accurate-Mass TOF Mass Spectrometer includes:\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eAgilent 6230A Single Quadrupole Mass Spectrometer\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eAgilent MS40+ Rotary Vane Vacuum Pump\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eAgilent G1958B Jet Stream Electrospray Ionization Source\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eWindows 10 Professional 64-Bit Data Station with Flatscreen Monitor\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eAgilent MassHunter B.09.01 Acquisition and Data Analysis Software Installed\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eAgilent MassHunter BioConfirm Software Installed\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eAll Power Cords\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eCan\/Crossover Cables\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eLab Advisor Diagnostics Report \u0026amp; Mass Spec Tuning Report\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eFull 180 Day Parts and Labor Warranty\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003ch2\u003eAgilent 6230A Accurate-Mass TOF Mass Spectrometer Specifications\u003c\/h2\u003e\n\t\u003ctable\u003e\n\t\u003ctbody\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tMS Sensitivity with AJS (Included)\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tSignal-to-noise ratio \u0026gt; 50:1, Noise = 1 × RMS (1 pg reserpine injected on-column, measured at m\/z 609.2807)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tMS Sensitivity with ESI (Option 200)\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tSignal-to-noise ratio \u0026gt; 10:1, Noise = 1 × RMS (1 pg reserpine injected on-column, measured at m\/z 609.2807)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tMass Resolving Power\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t22,000 FWHM (measured at m\/z 1,522 after automatic tuning procedure)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tMass Accuracy - MS Mode\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u0026lt; 1 ppm (measured at m\/z 609.2807 using an internal reference mass)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tSpectral Acquisition Rate - MS Mode\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t30 spectra\/second (spectra acquisition from m\/z 100 to 3,200)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDynamic Range\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tUp to 5 decades (in-scan dynamic range on co-eluting components)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tMass Range\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tm\/z 25 to 20,000\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tPolarity Switching\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u0026lt; 1 sec (pos\/neg switching)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tMass Accuracy Temperature Stability - MS Mode\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tMaintain 2 ppm mass accuracy within 2°C drift per hour (temperature: 15°C to 35°C (59°F to 95°F) at constant temperature while setting autotune at 25°C)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tSingle Point of Control\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tSingle point data system method capability with full control for HPLC system and TOF, stopping sample injection if errors or leaks occur\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tIonization sources\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tElectrospray (ESI), Atmospheric pressure chemical ionization (APCI), Atmospheric pressure photoionization (APPI), Multimode source (ESI and APCI), HPLC-Chip\/MS interface, AP\/MALDI PDF+ source\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tTransparent Introduction of Reference Masses\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tDual-sprayer orthogonal ESI source, built-in calibrant delivery system, real-time internal reference mass correction for MS operation and heated sources\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tAutotune\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tAutomated optimization of ion optics and full TOF MS mass axis calibration\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tData Mining Tools\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tOne-button extraction of compound-specific spectral and chromatographic information using find compounds algorithms\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tMolecular Profiling Tools\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tMeasurement of molecular features from LC\/MS analyses (MassHunter), differential expression analysis with optional MassHunter Mass Profiler\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tSound Emission\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u0026lt; 70 db\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDimensions (L x W x H)\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t32.7 x 28.7 x 52.4 in. (83 x 73 x 133 cm)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tWeight\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t260 lb. (117.9 kg)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tElectrical Requirements\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t200-220VAC, 50\/60Hz, 15A\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\t\u003c\/table\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003ctable\u003e\n\t\u003ctbody\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd colspan=\"2\" width=\"623\"\u003e\n\t\t\t\u003cp style=\"text-align: center;\"\u003e\n\t\t\t\t\tComputer Specifications\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t\tModel\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t\tDell Optiplex 7010 Desktop PC\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t\tProcessor\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t\tIntel Core i5-6500 Processor 3.2GHz\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t\tRAM\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t\t16GB\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t\tHard Drive\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t\t250GB Internal SSD\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t\tOperating System\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t\tWindows 10 Professional, 64bit\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\t\u003c\/table\u003e\n\t\u003cspan class=\"downloads-header\"\u003eDownloads\u003c\/span\u003e\n\t\u003cdiv class=\"downloads-section\"\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_6230A_Accurate-Mass_TOF_Mass_Spectrometer_-_Marshall_Scientific.pdf?v=1779985761\" target=\"blank\"\u003e\n\t\t\tTechnical Specification Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_6230A_Accurate-Mass_TOF_Mass_Spectrometer_Manual_-_Marshall_Scientific.pdf?v=1779985766\" target=\"blank\"\u003e\n\t\t\tOperator's Manual Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_6200_Series_TOF_Mass_Spectrometers_Site_Preparation_Guide_-_Marshall_Scientific.pdf?v=1779985769\" target=\"blank\"\u003e\n\t\t\tSite Prep Guide Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"formalquote2\"\u003e\n\t\t\u003ca class=\"formalquote2link\" href=\"\/formal_quote_a\/2950.htm\" target=\"blank\"\u003eRequest a Formal Quote\u003c\/a\u003e\n\t\u003c\/div\u003e\n\u003c\/div\u003e","brand":"My Store","offers":[{"title":"Default Title","offer_id":42474494689370,"sku":"AG-6230AMS","price":62995.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-6230AMS-2T.jpg?v=1780433292","url":"https:\/\/p2gnpt-0c.myshopify.com\/products\/agilent-6230a-accurate-mass-tof-mass-spectrometer","provider":"Marshall Scientific","version":"1.0","type":"link"}