{"product_id":"agilent-8453-g1103a-spectrophotometer-w-g1120a-multicell-transport","title":"Agilent 8453 G1103A Spectrophotometer w\/ G1120A Multicell Transport","description":"\u003cdiv class=\"productdescriptiontables\"\u003e\n\t\u003ch1\u003eAgilent 8453 G1103A Spectrophotometer w\/ G1120A Multicell Transport\u003c\/h1\u003e\n\n\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-section\"\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eWavelength Range\u003c\/b\u003e\u003cbr\u003e 190 - 1100 nm\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eWavelength Accuracy\u003c\/b\u003e\u003cbr\u003e\t\u0026lt; ± 0.5 nm\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003ePhotometric Accuracy \u003c\/b\u003e\u003cbr\u003e\u0026lt; ± 0.005 AU\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"features-section\"\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cspan class=\"features-header\"\u003eFeatures\u003c\/span\u003e\n\t\t\t\u003cul\u003e\n\t\t\t\t \u003cli\u003eDiode-array technology enables full-spectrum measurements in under one second\u003c\/li\u003e\n  \u003cli\u003eIntegrated multicell transport holds up to eight cells with automated positioning\u003c\/li\u003e\n  \u003cli\u003eThermostatted cell holder supports temperature control via external water bath\u003c\/li\u003e\n  \u003cli\u003eFlat spring design secures cells in position without additional hardware\u003c\/li\u003e\n  \u003cli\u003eSupports compliance with GLP and pharmacopoeia standards through reliable data handling\u003c\/li\u003e\n  \u003cli\u003eHigh photometric stability and low noise for consistent long-term performance\u003c\/li\u003e\n\t\t\t\u003c\/ul\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Ag-8453MCT-2T_0586b150-b9f0-49f9-8eb3-ad619a71f47b.jpg?v=1779985822\"\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\tThe Agilent 8453 UV-Vis Spectrophotometer uses a\nphotodiode array for simultaneous measurement of the complete ultra-violet to\nvisible light spectrum in less than one second, making it extremely efficient\nwithin the lab with exceptional reliability and repeatability. With its diode-array\ntechnology, the Agilent 8453 Spectrophotometer is much faster and more sensitive than\ncomparable conventional instruments. The Agilent 8453 UV-Vis system offers powerful\ndata analysis and data archival to ensure compliance with good laboratory\npractices (GLP) and pharmacopoeia requirements.\n\t\u003cbr\u003e\u003cbr\u003e\n\tThe Agilent G1120A Multicell Transport is also included with this system. The multicell transport cell holder holds eight cells in a rack which can be held at a constant temperature with water circulated from a thermostatic bath (provided by the user). The holder is attached to the multicell transport base which contains a stepper motor to move the designated cell into the optical path. A water-driven magnetic stirrer (not included) can be fitted under the holder in one of two positions, either under the cell in the optical path, or under the cell to the left of the cell in the optical path. \n\t\u003cbr\u003e\u003cbr\u003e\n\tThe outside dimensions of individual cells must be 12.5 × 12.5 mm and the height from base of the cell to the sample area 15 mm. During an analysis, the position of individual cells is maintained by a flat spring inside each of the cell compartments. The spring alone fixes the cell and no additional fixing mechanism is needed.\u003cbr\u003e\u003cbr\u003e\n\tAll of our equipment is fully tested to perform at factory specifications before being shipped.\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"included-box\"\u003e\n\t\t\u003cspan class=\"included-header\"\u003eINCLUDED:\u003c\/span\u003e\u003cbr\u003eAgilent 8453 G1103A Spectrophotometer w\/ G1120A Multicell Transport includes:\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003e New Tungsten Lamp\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003e New Deterium Lamp\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003e HP Windows 11 Laptop with B.04.01 Chemstation Software Pre-Installed\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003e Lan Interface Card\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003e G1120A Multicell Transport Cuvette Holder\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003e Passes Self Testing Report\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003e All Cables and Power Cords\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003e Operator's Guide\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003e Full 180 Day Parts and Labor Warranty\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\n\t\u003ch2\u003eAgilent 8453 G1103A Spectrophotometer w\/ G1120A Multicell Transport Specifications\u003c\/h2\u003e\n\t\u003ctable\u003e\n\t\u003ctbody\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tWavelength Range\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t190 - 1100 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tSlit Width\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t1 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tResolution\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u0026gt; 1.6\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tStray Light\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t\u0026lt; 1.0 % At 200 nm, solution of 1.2% KCl, blank scan on air, 5 s integration\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\ttime; (EP*method)**\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t\u0026lt; 0.05 % At 220 nm, solution of 10 g\/l NaI, blank scan on air, 5 s integration\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\ttime; (ASTM method)\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t\u0026lt; 0.03 % At 340 nm, solution of 50 g\/l NaNO2, blank scan on air, 5 s integration\n\t\t\t\u003c\/p\u003e\ntime; (ASTM method\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tWavelength Accuracy\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u0026lt; ± 0.5 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tWavelength Reproducibility\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u0026lt; ± 0.02 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tPhotometric Accuracy\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u0026lt; ± 0.005 AU\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tPhotometric Noise\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u0026lt; 0.0002 AU rms\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tPhotometric Stability\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u0026lt; 0.001 AU\/h\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tBaseline Flatness\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u0026lt; 0.001 AU rms\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tTypical Scan Time\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t1.5 s\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tShortest Scan Time\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t0.1 s\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tTime Until Next Scan\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t0.1 s\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tTime to Move Between Adjacent Cell Positions\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u0026lt; 1 second\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tPosition Repeatability\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t± 0.1 mm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tStep Resolution\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t0.060 mm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tTemperature Range for Thermostatting (Cell Holder Only)\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t5°C to 90°C\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tTemperature Difference Between any Two Cell Positions\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t0.3°C (with a water bath at 37°C)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDimensions (W x D x H)\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t13.5 x 22 x 7.3 in. (34.4 x 56 x 18.5 cm)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tWeight\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t36.3 lb. (16.5 kg)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tElectrical Requirements\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t100-120 or 220-240V, 50\/60Hz\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\t\u003c\/table\u003e\n\t\u003cspan class=\"downloads-header\"\u003eDownloads\u003c\/span\u003e\n\t\u003cdiv class=\"downloads-section\"\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_8453_G1103A_Spectrophotometer_with_G1120A_Multicell_Transport_-_Marshall_Scientific.pdf?v=1779985826\" target=\"blank\"\u003e\n\t\t\tTechnical Specification Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_8453_G1103A_Spectrophotometer_Manual_-_Marshall_Scientific.pdf?v=1779985831\" target=\"blank\"\u003e\n\t\t\tSpectrophotometer Manual Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_G1120A_Multicell_Transport_for_8453_Spectrophotometer_Manual_-_Marshall_Scientific.pdf?v=1779985835\" target=\"blank\"\u003e\n\t\t\tMulticell Transport Manual Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"formalquote2\"\u003e\n\t\t\u003ca class=\"formalquote2link\" href=\"\/formal_quote_a\/2576.htm\" target=\"blank\"\u003eRequest a Formal Quote\u003c\/a\u003e\n\t\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cspan class=\"windows11\" span=\"\"\u003e\u003c\/span\u003e","brand":"My Store","offers":[{"title":"Free Upgrade to Preloaded Desktop PC w\/ 24\" Monitor - ($500 Value)","offer_id":42474497409114,"sku":"Ag-8453MCT","price":6195.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Ag-8453MCT-2.jpg?v=1761207052","url":"https:\/\/p2gnpt-0c.myshopify.com\/products\/agilent-8453-g1103a-spectrophotometer-w-g1120a-multicell-transport","provider":"Marshall Scientific","version":"1.0","type":"link"}