{"product_id":"agilent-g1103b-cary-8454-uv-vis-spectrophotometer","title":"Agilent G1103B Cary 8454 Uv-Vis Spectrophotometer","description":"\u003cdiv class=\"productdescriptiontables\"\u003e\n\t\u003ch1\u003eAgilent G1103B Cary 8454 Uv-Vis Spectrophotometer\u003c\/h1\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-section\"\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eWavelength Range\u003c\/b\u003e\u003cbr\u003e 190 to 1100 nm\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eWavelength Accuracy\u003c\/b\u003e\u003cbr\u003e\u0026lt; ± 0.5 nm\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003ePhotometric Accuracy\t\n \u003c\/b\u003e\u003cbr\u003e± 0.005 AU\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"features-section\"\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cspan class=\"features-header\"\u003eFeatures\u003c\/span\u003e\n\t\t\t\u003cul\u003e\n\t\t\t\t\u003cli\u003eIdeal for QA\/QC labs, teaching environments, and chemical industries with robust performance\u003c\/li\u003e\n    \u003cli\u003eCaptures full spectra in as little as 0.1 seconds for rapid throughput\u003c\/li\u003e\n    \u003cli\u003eMinimized stray light and superior noise control ensure reliable sample verification\u003c\/li\u003e\n    \u003cli\u003eStable optics and low-noise electronics provide reproducible results without moving parts\u003c\/li\u003e\n    \u003cli\u003eTask-oriented software simplifies multi-wavelength and kinetic applications\u003c\/li\u003e\n    \u003cli\u003eMaintenance-friendly with pre-aligned, easily replaceable deuterium and tungsten lamps\u003c\/li\u003e\n    \u003cli\u003eCompact design with dimensions of 14 x 21 x 9 in. for easy integration into lab setups\u003c\/li\u003e\n    \u003cli\u003eSupports high-demand applications with time-based measurements and multi-component analysis\u003c\/li\u003e\n\t\t\t\u003c\/ul\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-8454-8T-Photoroom_f5645407-f9b4-46cf-bfd3-ee0c3351c25e.jpg?v=1779985860\"\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\n\tThe Agilent G1103B Cary 8454 UV-Visible Spectrophotometer is specifically designed for seamless operation in routine and complex applications, making it an excellent choice for quality assurance and quality control (QA\/QC) environments, academic teaching labs, and the chemical industry. Its durable construction is ideal for laboratories with multiple users, and its intuitive software complies with stringent global pharmaceutical regulations. This instrument's standout features include rapid spectral acquisition, with the ability to capture a full spectrum in as little as 0.1 seconds, and superior reproducibility thanks to stable optics and high-precision, low-noise electronics that operate without moving parts. Furthermore, the Agilent Cary 8454 offers straightforward operation through task-oriented application software and features direct access to cells and cell holders for efficient sample management. Maintenance is simplified with easily replaceable pre-aligned deuterium and tungsten lamps, and built-in software and firmware enhancements support Good Laboratory Practice (GLP) standards.\n\t\u003cbr\u003e\u003cbr\u003e\n\tThe Agilent Cary 8454 covers a broad wavelength range from 190 to 1100 nm and utilizes dual lamp types—deuterium for the UV to near-visible spectrum and tungsten for the visible to near-infrared spectrum. This spectrophotometer ensures exceptional wavelength accuracy, typically within ± 0.5 nm, and maintains precise photometric accuracy across various tests. Its advanced design minimizes stray light and ensures impressive spectral resolution and noise control, critical for accurate sample analysis and verification. The device's rapid spectrum read time, which can be as quick as 0.1 seconds, not only enhances laboratory throughput but also facilitates immediate result acquisition and analysis, critical in high-demand settings. With capabilities for time-based measurements and support for complex multi-component software, the Cary 8454 is adept at handling multi-wavelength and kinetic applications, providing reliable and repeatable results that are essential for method validation and regulatory compliance. This makes the Agilent Cary 8454 UV-Visible Spectrophotometer a robust analytical tool that meets the diverse and demanding needs of modern chemical and pharmaceutical laboratories.\n\t\u003cbr\u003e\u003cbr\u003eAll of our equipment is fully tested to perform at factory\nspecifications before being shipped.\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"included-box\"\u003e\n\t\t\u003cspan class=\"included-header\"\u003eINCLUDED:\u003c\/span\u003e\u003cbr\u003eThe Agilent G1103B Cary 8454 Uv-Vis Spectrophotometer includes:\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003e New Tungsten Lamp\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003e New Deterium Lamp\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003e HP Windows 11 Laptop with UV-Visible ChemStation Version B.05.04 Pre-Installed\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003e Lan Interface Card\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eSelf Test Calibration Report\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003ePower Cord\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eFull 180 Day Parts and Labor Warranty\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\n\t\u003ch2\u003eAgilent G1103B Cary 8454 Uv-Vis Spectrophotometer Specifications\u003c\/h2\u003e\n\t\u003ctable\u003e\n\t\u003ctbody\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tWavelength Range\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t190 to 1100 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tLamps\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tDeuterium: 190 nm to approximately 800 nm\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tTungsten: 370 nm to 1100 nm\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tWavelength Accuracy\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tWithin ± 0.5 nm for 14 validated transmission peak minima of a certified NIST-traceable holmium oxide in perchlorate solution\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tPhotometric Accuracy\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tWithin ± 0.005 AU at 440, 465, 546.1, 590, and 635 nm at approximately 1 AU using the NIST-traceable 930e\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t± 0.01 AU at 235, 257, 313, 350 nm using a 6 % w\/v potassium dichromate NIST-traceable 935a solution in 0.01 N sulfuric acid\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tStray Light\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t\u0026gt; 0.03% at 340 nm measured with 50 g\/l NaNO2 solution\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t\u0026gt; 0.05% at 220 nm measured with 10 g\/l NaI solution\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t\u0026gt; 1% at 198 nm measured with 1.2% KCl solution\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tResolution\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tThe ratio of the absorbances at 269 and 266 nm of a 0.02 % v\/v solution toluene in hexane is greater than 1.5\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tNoise\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u0026gt; 0.0002 AU rms (root mean square) at 500 nm and 0 AU\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tBaseline Flatness\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u0026gt; 0.001 AU rms at 0 AU\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tStability\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u0026gt; 0.001 AU at 340 nm at 0 AU\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tSpectrum Read Time\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tAs little as 0.1 seconds\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDimensions (W x D x H)\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t14 x 21 x 9 in. (35.5 x 53 x 22.8 cm)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tWeight\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t41 lb. (18.6 kg)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tElectrical Requirements\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t100-240V, 50\/60Hz\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\t\u003c\/table\u003e\n\t\u003cbr\u003e\n\t\u003ctable\u003e\n\t\u003ctbody\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd colspan=\"2\" width=\"623\"\u003e\n\t\t\t\u003cp style=\"text-align: center;\"\u003e\n\t\t\t\tComputer Specifications\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tModel\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tHewlett-Packard\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tProcessor\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tIntel Core I5-8200U CPU\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tRAM\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t16.0 GB\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tHard Drive\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t240GB Internal SSD\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tOperating System\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tWindows 11 Professional, 64-bit\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\t\u003c\/table\u003e\n\t\u003cspan class=\"downloads-header\"\u003eDownloads\u003c\/span\u003e\n\t\u003cdiv class=\"downloads-section\"\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_G1103B_Cary_8454_Uv-Vis_Spectrophotometer_-_Marshall_Scientific.pdf?v=1779985865\" target=\"blank\"\u003e\n\t\t\tTechnical Specification Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_G1103B_Cary_8454_Uv-Vis_Spectrophotometer_Manual_-_Marshall_Scientific.pdf?v=1779985893\" target=\"blank\"\u003e\n\t\t\tOperator's Manual Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"formalquote2\"\u003e\n\t\t\u003ca class=\"formalquote2link\" href=\"\/formal_quote_a\/2708.htm\" target=\"blank\"\u003eRequest a Formal Quote\u003c\/a\u003e\n\t\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cspan class=\"windows11\"\u003e\u003c\/span\u003e","brand":"My Store","offers":[{"title":"Default Title","offer_id":42474497572954,"sku":"AG-8454","price":6395.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-8454-2.jpg?v=1761207081","url":"https:\/\/p2gnpt-0c.myshopify.com\/products\/agilent-g1103b-cary-8454-uv-vis-spectrophotometer","provider":"Marshall Scientific","version":"1.0","type":"link"}