{"product_id":"applied-biosystems-7500-fast-dx-real-time-pcr-system","title":"Applied Biosystems 7500 Fast Dx Real-Time PCR System","description":"\u003cdiv class=\"productdescriptiontables\"\u003e\n\u003ch1\u003eApplied Biosystems 7500 Fast Dx Real-Time PCR System\u003c\/h1\u003e\n\u003cbr\u003e\u003cbr\u003e\n\u003cdiv class=\"highlights-divider\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"highlights-section\"\u003e\n\u003cdiv class=\"inner-highlight-div\"\u003e\n\u003cp class=\"inner-highlight\"\u003e\u003cb\u003eBlock Configuration\u003c\/b\u003e\u003cbr\u003e96-Well Fast\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"inner-highlight-div\"\u003e\n\u003cp class=\"inner-highlight\"\u003e\u003cb\u003ePeak Block Heating Rate\u003c\/b\u003e\u003cbr\u003e5.5°C\/second\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"inner-highlight-div\"\u003e\n\u003cp class=\"inner-highlight\"\u003e\u003cb\u003eTemperature Uniformity\u003c\/b\u003e\u003cbr\u003e± 1°C\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"highlights-divider\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"features-section\"\u003e\n\u003cdiv class=\"features-side\"\u003e\n\u003cspan class=\"features-header\"\u003eFeatures\u003c\/span\u003e\n\u003cul\u003e\n\u003cli\u003eFast cycling technology allows for more runs to be completed per day\u003c\/li\u003e\n\u003cli\u003eFaster ramp rates enable quick temperature changes without sacrificing performance\u003c\/li\u003e\n\u003cli\u003eHighly suitable for a variety of applications including gene expression analysis and DNA quantification\u003c\/li\u003e\n\u003cli\u003eIntegrated real-time PCR solutions with optimized reagents and customizable assays\u003c\/li\u003e\n\u003cli\u003eCapable of delivering results in less than 40 minutes\u003c\/li\u003e\n\u003cli\u003eOptical system includes CCD camera and halogen lamp with five excitation and emission filters\u003c\/li\u003e\n\u003cli\u003eSupports multiplexing of up to five targets per well\u003c\/li\u003e\n\u003cli\u003eFeatures a dynamic range of nine logs\u003c\/li\u003e\n\u003cli\u003eSensitivity to detect one copy of a template in 20 µL reactions with 99.7% confidence\u003c\/li\u003e\n\u003cli\u003eFDA 510(k)-cleared for In Vitro Diagnostic (IVD) use\u003c\/li\u003e\n\u003cli\u003eSDS v1.4.1 software features Security, Auditing and E-Signature features, which support regulated environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"features-side\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AB-7500F_36e391f5-c726-4d39-b288-8f0b1b307268.jpg?v=1779986097\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cbr\u003eThe Applied Biosystems 7500 Fast Dx Real-Time PCR System, FDA-cleared for In Vitro Diagnostic (IVD) use, delivers reliable, high-throughput detection of nucleic acid targets with five-color fluorescence capability. This system, built on over ten years of real-time PCR innovation, is tailored for high-throughput environments requiring both speed and accuracy. It features a unique 96-well Fast block that accommodates reaction volumes from 10 to 30 uL, but is optimized for 10 uL, ensuring consistent thermal uniformity across all samples. \u003cbr\u003e\u003cbr\u003eThe system's rapid ramp rates accelerate the processing times to deliver results in less than 40 minutes without compromising the extension times or the quality of the assay. This efficiency is matched by the system’s robust temperature controls, maintaining a uniformity of ± 1°C and an accuracy of ± 0.5°C, which are crucial for precise thermal cycling. Additionally, the optical system uses a CCD camera coupled with a halogen lamp for excitation, along with five excitation and emission filters, enabling sensitive multiplex detection of up to five targets per well. \u003cbr\u003e\u003cbr\u003eWith a dynamic range extending over nine logs, the 7500 Fast Dx can detect as little as one copy of a template in a 20 uL reaction with 99.7% confidence. This system is not only a testament to Applied Biosystems' legacy of quality and innovation but also an essential tool for modern laboratories focused on genetic analysis and molecular diagnostics. The SDS v1.4.1 software on the 7500 Fast Dx has Security, Auditing and E-Signature features, which support regulated environments. \u003cb\u003ePlease Note: We recommend performing a Dye Calibration for the Dye you plan on using for your application(s). Please refer to the Operator's Manual for instructions. This instrument has been discontinued by the manufacturer but remains suitable for validated IVD applications and laboratory use.\u003c\/b\u003e \u003cbr\u003e\u003cbr\u003eAll of our equipment is fully tested to perform at factory specifications before being shipped.\u003cbr\u003e\u003cbr\u003e\n\u003cdiv class=\"included-box\"\u003e\n\u003cspan class=\"included-header\"\u003eINCLUDED:\u003c\/span\u003e\u003cbr\u003eThe Applied Biosystems 7500 Fast Dx Real-Time PCR System includes:\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003e96-Well Fast Block\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eNew Halogen Lamp\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eBackground Calibration Report\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eROI Calibration Report\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eOptical Calibration Report\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eWindows 11 Professional 64-Bit Data Station\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eApplied Biosystems 7500 Dx SDS Software Version 1.4.1 Installed\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003ePower Cord\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eOperator's Manual\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eFull 180 Day Parts and Labor Warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003ch2\u003eApplied Biosystems 7500 Fast Dx Real-Time PCR System Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlock Configuration\u003c\/td\u003e\n\u003ctd\u003e96-Well Fast (10 to 30 uL reactions, optimized for 10 uL reactions)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample Format\u003c\/td\u003e\n\u003ctd\u003eFast 96-Well plates (100 uL) or 8-tube strips (100 uL)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e4°C to 99.9°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Uniformity\u003c\/td\u003e\n\u003ctd\u003e± 1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e± 0.5°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample Ramp Rate\u003c\/td\u003e\n\u003ctd\u003eFast mode: 3.5°C\/sec \u003cbr\u003eStandard mode: 1.6°C\/sec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak Block Heating Rate\u003c\/td\u003e\n\u003ctd\u003e5.5°C\/second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRun Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 40 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptical System\u003c\/td\u003e\n\u003ctd\u003eCCD camera with halogen lamp excitation; five-exciation and five-emission filters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDynamic Range\u003c\/td\u003e\n\u003ctd\u003e9 logs of linear dynamic range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003eDetection of 1 copy of template in 20 uL reaction for a single reporter TaqMan assay, with 99.7% confidence\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMultiplexing\u003c\/td\u003e\n\u003ctd\u003eUp to 5 targets per well\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDye Compatibility\u003c\/td\u003e\n\u003ctd\u003eFAM\/SYBR Green, VIC\/JOE, NED\/TAMRA\/Cy3, ROX\/Texas Red, and Cy5 (Calibration for new dyes within the wavelength range is possible by following the custom dye calibration procedure in the user’s manual)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePassive Reference Dyes\u003c\/td\u003e\n\u003ctd\u003eROX dye or any calibrated dye (use of a passive reference dye is optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e13.9 x 17.7 x 19.3 in. (34 x 45 x 49 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e75 lb. (34 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Requirements\u003c\/td\u003e\n\u003ctd\u003e100-240V, 50\/60Hz, 1080W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cspan class=\"downloads-header\"\u003eDownloads\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"downloads-section\"\u003e\n\u003cdiv class=\"pdf-button\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Applied_Biosystems_7500_Fast_Dx_Real-Time_PCR_System_-_Marshall_Scientific.pdf?v=1779986102\"\u003e Technical Specification Download \u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"pdf-button\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Applied_Biosystems_7500_Fast_Dx_Real-Time_PCR_System_Manual_-_Marshall_Scientific.pdf?v=1779986108\"\u003e Operator's Manual Download \u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"formalquote2\"\u003e\u003ca class=\"formalquote2link\" href=\"\/formal_quote_a\/3025.htm\"\u003eRequest a Formal Quote\u003c\/a\u003e\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Marshall scientific","offers":[{"title":"Default Title","offer_id":42502151962714,"sku":"AB-7500FDX","price":9995.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AB-7500FDX-2T.jpg?v=1780430591","url":"https:\/\/p2gnpt-0c.myshopify.com\/products\/applied-biosystems-7500-fast-dx-real-time-pcr-system","provider":"Marshall Scientific","version":"1.0","type":"link"}