{"product_id":"applied-biosystems-openarray-accufill-system","title":"Applied Biosystems OpenArray AccuFill System","description":"\u003cdiv class=\"productdescriptiontables\"\u003e\n\t\u003ch1\u003eApplied Biosystems OpenArray AccuFill System\u003c\/h1\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-section\"\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eFill Rate\u003c\/b\u003e\u003cbr\u003e99.25%\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eMaximum Allowable Sample Carryover\u003c\/b\u003e\u003cbr\u003e\u0026lt; 1%\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eMaximum Allowable Assay Carryover\u003c\/b\u003e\u003cbr\u003e\u0026lt; 1%\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"features-section\"\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cspan class=\"features-header\"\u003eFeatures\u003c\/span\u003e\n\t\t\t\u003cul\u003e\n\t\t\t\t\u003cli\u003eAutomated transfer of samples and PCR master mix from 384-well plates to OpenArray plates\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eCapillary-based loading with self-metering through-holes for consistent reaction volumes\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eBubble-free dispensing enabled by an open-well, through-hole plate design\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eOptimized for high-throughput real-time PCR and genotyping workflows\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eCompatible with SYBR, OpenArray Real-Time PCR, TaqMan OpenArray Real-Time PCR, and TaqMan OpenArray Genotyping chemistries\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eHigh throughput equivalent to eight traditional 384-well plates per OpenArray plate\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eAbility to process up to four OpenArray plates per run for large-scale studies\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eIntuitive software for plate setup, sample mapping, file generation, and data integration\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eHigh performance metrics including a typical 99.25% fill rate and minimal sample or assay carryover\u003c\/li\u003e\n\t\t\t\u003c\/ul\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AB-OAAF.jpg?v=1779986129\"\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003eThe Applied Biosystems OpenArray AccuFill System is an automated, high-throughput sample loading platform designed to precisely transfer DNA samples and PCR master mix from standard 384-well plates onto OpenArray Plates for real-time PCR analysis. The system uses capillary action to draw samples into AccuFill tips and dispense them evenly across the OpenArray plate surface, where self-metering through-holes automatically fill to the correct reaction volume without the need for pressure-based dispensing or manual volume control. Because the OpenArray format contains no closed wells, air bubbles are not trapped during loading, resulting in highly uniform fills and excellent data consistency.\n\t\u003cbr\u003e\u003cbr\u003e\n\tOptimized specifically for downstream real-time PCR workflows, the AccuFill System supports SYBR, OpenArray Real-Time PCR, TaqMan OpenArray Real-Time PCR, and TaqMan OpenArray Genotyping chemistries. OpenArray technology significantly increases throughput and efficiency: a single QuantStudio™ 12K Flex OpenArray plate is equivalent to eight conventional 384-well plates, and the system can process up to four OpenArray plates per run. This enables laboratories to analyze up to 1,728 genotyping samples or 2,304 gene expression samples within an 8-hour workday, with the option for offline thermal cycling to further optimize instrument utilization.\n\t\u003cbr\u003e\u003cbr\u003e\n\tThe accompanying OpenArray AccuFill v2.0 software provides end-to-end workflow control, including sample plate setup, mapping from 96-well to 384-well formats, support for multi-sample loading, and generation of all required plate files (TPF, SPF, loaded files, and CSV outputs) for compatible Applied Biosystems™ real-time PCR instruments. The software also includes plate orientation correction, loading history tracking, and sample integration capabilities to streamline data management. Designed for reliability and reproducibility, the system delivers a typical fill rate of 99.25%, with maximum allowable sample and assay carryover below 1% and less than 5% data loss due to evaporation, making it a robust solution for high-density, high-confidence qPCR applications\n\t\u003cbr\u003e\u003cbr\u003eAll of our equipment is fully tested to perform at factory specifications before being shipped.\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"included-box\"\u003e\n\t\t\u003cspan class=\"included-header\"\u003eINCLUDED:\u003c\/span\u003e\u003cbr\u003eThe Applied Biosystems OpenArray AccuFill System includes:\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eOpenArray Plate Press 2\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eWaste Bin\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eWindows 11 Professional 64-Bit Data Station with Flatscreen Monitor\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eOpenArray AccuFill v2.0 Software Installed\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003ePower Cord\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eOperator's Manual\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eFull 180 Day Parts and Labor Warranty\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\n\t\u003ch2\u003eApplied Biosystems OpenArray AccuFill System Specifications\u003c\/h2\u003e\n\t\u003ctable\u003e\n\t\u003ctbody\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tFill Rate\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t99.25%\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tMaximum Allowable Sample Carryover\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u0026lt; 1%\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tMaximum Allowable Assay Carryover\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u0026lt; 1%\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tMaximum Number of Through-Hole Data Points Lost Due to Evaporation\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u0026lt; 5%\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDimensions (H x D x W)\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t34.5 x 40 x 42 in. (87.6 x 101.6 x 106.7 cm)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tWeight\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t243 lb. (110.2 kg)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tElectrical Requirements\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t100 to 240VAC, 50\/60Hz, 4A\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\t\u003c\/table\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003ctable\u003e\n\t\u003ctbody\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd colspan=\"2\"\u003e\n\t\t\t\u003ccenter\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t\tComputer Specifications\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003c\/center\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\tProcessor\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\tIntel Core I5-8500 CPU\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\tRAM\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\t32.0 GB\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\tHard Drive\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\t500GB Internal SSD\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\tOperating System\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\tWindows 11 Professional, 64-bit\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\t\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cspan class=\"downloads-header\"\u003eDownloads\u003c\/span\u003e\n\u003cdiv class=\"downloads-section\"\u003e\n\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Applied_Biosystems_QuantStudio_12K_Flex_Real-Time_PCR_System_-_Marshall_Scientific.pdf?v=1779986136\" target=\"blank\"\u003e\n\t\tTechnical Specification Download\n\t\t\u003c\/a\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Applied_Biosystems_OpenArray_AccuFill_System_Manual_-_Marshall_Scientific.pdf?v=1779986141\" target=\"blank\"\u003e\n\t\tOperator's Manual Download\n\t\t\u003c\/a\u003e\n\t\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"formalquote2\"\u003e\n\t\u003ca class=\"formalquote2link\" href=\"\/formal_quote_a\/3118.htm\" target=\"blank\"\u003eRequest a Formal Quote\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cspan class=\"windows11\"\u003e\u003c\/span\u003e\n\n\u003cstyle\u003e\n .fpt-container {\n  width: 50%;\n }\n .fpt-box {\n   width: 45%;\n }\n\u003c\/style\u003e","brand":"Marshall scientific","offers":[{"title":"Default Title","offer_id":43428344561754,"sku":"AB-OAAF","price":12840.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AB-OAAF-2T.jpg?v=1779979759","url":"https:\/\/p2gnpt-0c.myshopify.com\/products\/applied-biosystems-openarray-accufill-system","provider":"Marshall Scientific","version":"1.0","type":"link"}