{"product_id":"applied-biosystems-viia-7-real-time-pcr-system-w-384-well-sample-block","title":"Applied Biosystems ViiA 7 Real-Time PCR System w\/ 384-Well Sample Block","description":"\u003cdiv class=\"productdescriptiontables\"\u003e\n\t\u003ch1\u003eApplied Biosystems ViiA 7 Real-Time PCR System w\/ 384-Well Sample Block\u003c\/h1\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-section\"\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eBlock Configuration\u003c\/b\u003e\u003cbr\u003e384-Well (5 to 20 uL reactions)\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eRun Time\u003c\/b\u003e\u003cbr\u003e~ 35 Minutes\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eExcitation\/Detection Wavelengths\u003c\/b\u003e\u003cbr\u003eEX: 450 to 670 nm \/ EM: 500 to 720 nm (Filter-based)\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"features-section\"\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cspan class=\"features-header\"\u003eFeatures\u003c\/span\u003e\n\t\t\t\u003cul\u003e\n\t\t\t\t\u003cli\u003eOptiFlex system with six excitation and six emission filters for high-resolution detection\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eDetects as little as 1.5-fold changes in singleplex target quantities\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eFront-access block change in under one minute with no tools required\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eIntuitive 7\" touchscreen interface with one-touch protocol setup\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eCompatible with TaqMan Array Micro Fluidic Cards for high-throughput workflows\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eSupports up to nine logs of linear dynamic range and single-copy sensitivity\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eAutomation-ready and integrates with the Twister II Robot for scalable throughput\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eBuilt-in data recovery for over 100 runs ensures workflow continuity\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eFully configurable data export formats for flexible downstream analysis\u003c\/li\u003e\n\t\t\t\u003c\/ul\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AB-VIIA384_64ce3954-0b8d-42b1-b7ef-de29a8e9ec4c.jpg?v=1779986217\"\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003eThe Applied Biosystems ViiA 7 Real-Time PCR System with 384-Well Sample Block is a high-throughput qPCR platform designed to deliver exceptional performance, reliability, and flexibility for demanding research environments. Engineered with a front-access interchangeable block system, it allows for rapid block changes in under one minute without tools or disconnecting peripherals. The 384-well format supports reaction volumes from 5 to 20 µL and enables fast run times of approximately 35 minutes, making it ideal for medium- to high-throughput applications. At the core of the system is the advanced OptiFlex fluorescence detection module, featuring six independent excitation (450 - 670 nm) and six emission (500 - 720 nm) filters, offering unmatched multiplexing capabilities and precise quantification, detecting target changes as small as 1.5-fold in singleplex reactions.\n\t\u003cbr\u003e\u003cbr\u003e\n\tThe ViiA 7 System supports a fully integrated workflow, with compatibility for standard and fast 96-well plates, 384-well plates, as well as TaqMan® Array Micro Fluidic Cards, allowing users to perform hundreds of assays without the need for liquid-handling robotics. A user-friendly 7\" color touchscreen interface, one-touch protocols, and automation readiness via the Twister II Robot (not included) ensure streamlined operation and scalability. Enhanced software tools include customizable export formats, ramp rate detection flexibility, and robust data recovery capabilities for over 100 runs. With a dynamic range extending up to nine logs and the sensitivity to detect down to a single copy, the ViiA 7 delivers high-quality, reproducible results instrument to instrument and run to run, empowering researchers to achieve more, faster. \u003cb\u003ePlease Note: We recommend performing a Dye Calibration for the Dye you plan on using for your application(s). Please refer to the Operator's Manual for instructions.\u003c\/b\u003e\n\t\u003cbr\u003e\u003cbr\u003eAll of our equipment is fully tested to perform at factory specifications before being shipped.\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"included-box\"\u003e\n\t\t\u003cspan class=\"included-header\"\u003eINCLUDED:\u003c\/span\u003e\u003cbr\u003eThe Applied Biosystems ViiA 7 Real-Time PCR System w\/ 384-Well Sample Block includes:\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003e384-Well Block\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003e384-Well Heated Cover\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eBackground Calibration Report\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eROI Calibration Report\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eUniformity Calibration Report\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eWindows 11 Professional 64-Bit Data Station with Flatscreen Monitor\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eQuantStudio Real-Time PCR Software Version 1.6.1 Installed\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003ePower Cord\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eOperator's Manual\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eFull 180 Day Parts and Labor Warranty\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\n\t\u003ch2\u003eApplied Biosystems ViiA 7 Real-Time PCR System w\/ 384-Well Sample Block Specifications\u003c\/h2\u003e\n\t\u003ctable\u003e\n\t\u003ctbody\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tBlock Configuration\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t384-Well (5 to 20 uL reactions)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tBlock Change Design\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tBlock change from front of instrument in less than 1 minute; no secondary tools required\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tRun Time\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t~ 35 minutes for 384-Well\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDemonstrated Sensitivity\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tDown to 1 copy\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDynamic Range\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tUp to 9 logs of linear dynamic range\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tResolution\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tDetect changes as little as 1.5-fold in target quantities in singleplex reaction\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tExcitation\/Detection Wavelengths\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t6 Excitation: 450 to 670 nm\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t6 Emission: 500 to 720 nm\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tData Export Format\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tFully configurable by user\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDimensions (W x D x H)\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t21 x 25 x 25.4 in. (53.3 x 63.5 x 64.5 cm)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tWeight\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t148 lb. (66.9 kg)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tElectrical Requirements\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t100-240V, 50\/60Hz, 12.5A\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\t\u003c\/table\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003ctable\u003e\n\t\u003ctbody\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd colspan=\"2\"\u003e\n\t\t\t\u003ccenter\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t\tComputer Specifications\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003c\/center\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\tProcessor\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\tIntel Core I5-8500 CPU\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\tRAM\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\t32.0 GB\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\tHard Drive\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\t500GB Internal SSD\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\tOperating System\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\tWindows 11 Professional, 64-bit\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\t\u003c\/table\u003e\n\t\u003cspan class=\"downloads-header\"\u003eDownloads\u003c\/span\u003e\n\t\u003cdiv class=\"downloads-section\"\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Applied_Biosystems_ViiA_7_Real-Time_PCR_System_with_384-Well_Sample_Block_-_Marshall_Scientific.pdf?v=1779986221\" target=\"blank\"\u003e\n\t\t\tTechnical Specification Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Applied_Biosystems_ViiA_7_Real-Time_PCR_System_with_384-Well_Sample_Block_Manual_-_Marshall_Scientific.pdf?v=1779986226\" target=\"blank\"\u003e\n\t\t\tOperator's Manual Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"formalquote2\"\u003e\n\t\t\u003ca class=\"formalquote2link\" href=\"\/formal_quote_a\/2902.htm\" target=\"blank\"\u003eRequest a Formal Quote\u003c\/a\u003e\n\t\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cspan class=\"windows11\"\u003e\u003c\/span\u003e","brand":"My Store","offers":[{"title":"Default Title","offer_id":42474438885466,"sku":"AB-VIIA384","price":7995.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AB-VIIA384-2.jpg?v=1761204262","url":"https:\/\/p2gnpt-0c.myshopify.com\/products\/applied-biosystems-viia-7-real-time-pcr-system-w-384-well-sample-block","provider":"Marshall Scientific","version":"1.0","type":"link"}