{"product_id":"beckman-coulter-allegra-x-14r-refrigerated-centrifuge","title":"Beckman Coulter Allegra X-14R Refrigerated Centrifuge","description":"\u003cdiv class=\"productdescriptiontables\"\u003e\n\t\u003ch1\u003eBeckman Coulter Allegra X-14R Refrigerated Centrifuge\u003c\/h1\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-section\"\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eMaximum Capacity\n\t\t\t\t\u003c\/b\u003e\u003cbr\u003e 4 x 750ml\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eMaximum Speed\n\t\t\t\t\u003c\/b\u003e\u003cbr\u003e10,200 RPM (4,300 RPM with included rotor)\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eTemperature Range\u003c\/b\u003e\u003cbr\u003e2°C to 40°C in 1°C Increments\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"features-section\"\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cspan class=\"features-header\"\u003eFeatures\u003c\/span\u003e\n\t\t\t\u003cul\u003e\n\t\t\t\t\u003cli\u003eMicroprocessor-controlled for interactive operation and features a brushless asynchronous motor for reliable performance\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eAutomatic rotor identification system ensures the centrifuge operates within safe speed limits for the installed rotor, enhancing user safety\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eProgrammable memory allows for easy setup of repeat run conditions, paired with an advanced temperature control system ranging from 2°C to 40°C\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eEasy-to-use control panel angled for optimal visibility and access, facilitating straightforward operation\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eComprehensive safety features include an imbalance detector that triggers an automatic shutdown if rotor loads are unbalanced\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eSupports a variety of applications with a maximum speed of 10,200 RPM and an RCF of up to 11,400 x g\u003c\/li\u003e\n\t\t\t\t\u003cli\u003e\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003eInclusive of a timer that can be set up to 9 hours 59 minutes or set to continuous run for extended operations\u003c\/span\u003e\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eOperates quietly with a noise level of less than 64 dBa, contributing to a more comfortable lab environment\u003c\/li\u003e\n\t\t\t\u003c\/ul\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Beckman_X-14R_Features_Section.jpg?v=1779986470\"\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003eThe Beckman Coulter Allegra X-14R Refrigerated Centrifuge is a benchtop refrigerated centrifuge that generates centrifugal forces required for a wide variety of applications. The Allegra X-14R is microprocessor-controlled, providing interactive operation. The instrument design features a brushless asynchronous motor, automatic rotor identification system, program memory that enables repeated run conditions, temperature control system from 2°C to 40°C, and a choice of acceleration and deceleration rates. User messages alert the operator to conditions that may need attention. The Beckman Coulter Allegra X-14R Refrigerated Centrifuge also features an easy to use control panel, which is mounted at an angle on the front of the centrifuge for easy visibility and access. A rotor identification system prevents the installed rotor from running above its maximum rated speed. During acceleration the microprocessor checks the magnetic rotor identification. Speed is limited to the maximum safe speed of the identified rotor. If the system identifies a rotor different than the one entered by the user, the system displays an error message and reduces the speed to the maximum allowable speed of the rotor. An imbalance detector monitors the rotor during the run, causing automatic shutdown if rotor loads are severely out of balance. \u003cb\u003eThe included rotor reaches a maximum speed of 4,300 RPM. \u003c\/b\u003e\u003cbr\u003e\u003cbr\u003eAll of our equipment is in excellent condition and will be fully tested to perform at factory specifications before being shipped.\n\t\u003cbr\u003e\u003cbr\u003ePlease confirm this rotor meets your application needs and request a different rotor, if necessary. Available rotors can be found in our \u003ca href=\"https:\/\/www.marshallscientific.com\/rotor_compatibility_guide_a\/326.htm\" target=\"_blank\"\u003eRotor Compatibility Guide\u003c\/a\u003e.\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"included-box\"\u003e\n\t\t\u003cspan class=\"included-header\"\u003eINCLUDED:\u003c\/span\u003e\u003cbr\u003eThe Beckman Coulter Allegra X-14R Refrigerated Centrifuge includes:\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eSX4750A Swing Bucket Rotor\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eSet of 4 x SX4750 Round Buckets\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eSet of 2 x 15ml Adapters\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eSet of 2 x 50ml Adapters\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003e NIST Centrifuge Calibration and Preventative Maintenance Report\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003e Power Cord\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003e Operator's Guide\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003e Full 180 Day Parts and Labor Warranty\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\n\t\u003ch2\u003eBeckman Coulter Allegra X-14R Refrigerated Centrifuge Specifications\u003c\/h2\u003e\n\t\u003ctable\u003e\n\t\u003ctbody\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tMaximum Speed\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t10,200 RPM (4,300 RPM with included rotor)\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tMaximum RCF\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t11,400 x g (4,303 x g with included rotor)\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tMaximum Capacity\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t4 x 750ml\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tTemperature Range\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t2°C to 40°C in 1°C Increments\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tTimer\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tUp to 9 hours 59 minutes, or continuous run (hold)\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tAcceleration Rates\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t10\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDeceleration Rates\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t11\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tNoise Level\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t \u0026lt; 64 dBa\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tMaximum Heat Dissipation\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t4318 Btu\/hr (1.3 kW)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tDimensions (W x D x H)\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t30 x 26.5 x 16.5 in. (76.2 x 67.3 x 41.9 cm)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tWeight\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t283 lb. (128 kg)\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tElectrical Requirements\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t120V, 60Hz, 12A\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\t\u003c\/table\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003ch2 class=\"pm-header\"\u003ePreventative Maintenance Performed on The Beckman Coulter Allegra X-14R Refrigerated Centrifuge\u003c\/h2\u003e\n\t\u003cul class=\"pm-list\"\u003e\n\t\t\u003cli\u003eDoor Latch Assembly Checked for Full Function\u003c\/li\u003e\n\t\t\u003cli\u003eDoor Hinges are Checked and Lubed as Needed\u003c\/li\u003e\n\t\t\u003cli\u003eDrive Belt is Checked for Rips and Tears and Replaced if Needed\u003c\/li\u003e\n\t\t\u003cli\u003eRotors and O-rings are Lubed as Needed\u003c\/li\u003e\n\t\t\u003cli\u003eLamps and Display are Checked and Replaced if Dim\u003c\/li\u003e\n\t\t\u003cli\u003eLine Cord is Checked for Signs of Fray or Damage and Replaced Accordingly\u003c\/li\u003e\n\t\t\u003cli\u003eInternal Circuitry is Checked for Faulty\/Shorted Components and Replaced Accordingly\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003cbr\u003e\u003ca href=\"https:\/\/www.marshallscientific.com\/Articles.asp?ID=326\" target=\"blank\" style=\"background-color: initial; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/rotor_compatibility_guide.png?v=1779986400\"\u003e\u003cbr\u003e\u003c\/a\u003e\n\t\u003cp class=\"MsoNormal\"\u003e\n\t\t\u003co:p\u003e \u003c\/o:p\u003e\n\t\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cspan class=\"downloads-header\"\u003eDownloads\u003c\/span\u003e\n\u003cdiv class=\"downloads-section\"\u003e\n\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Beckman_Coulter_Allegra_X-14R_Refrigerated_Centrifuge_-_Marshall_Scientific.pdf?v=1779986474\" target=\"blank\"\u003e\n\t\tTechnical Specification Download\n\t\t\u003c\/a\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Beckman_Coulter_Allegra_X-14_Centrifuge_Series_Manual_-_Marshall_Scientific.pdf?v=1779986466\" target=\"blank\"\u003e\n\t\tOperator's Manual Download\n\t\t\u003c\/a\u003e\n\t\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"formalquote2\"\u003e\n\t\u003ca class=\"formalquote2link\" href=\"\/formal_quote_a\/2421.htm\" target=\"blank\"\u003eRequest a Formal Quote\u003c\/a\u003e\n\u003c\/div\u003e","brand":"My Store","offers":[{"title":"Beckman Multiwell-Plate Carriers for SX4750\/SX4750A\/JS-4.750 Rotor (Additional $925.00) \/ 4 x Beckman SX4750\/SX4750A Bucket Caps (Additional $253.25)","offer_id":42474538598490,"sku":"BE-AX14R","price":7973.25,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/BE-AX14R-2.jpg?v=1761210535","url":"https:\/\/p2gnpt-0c.myshopify.com\/products\/beckman-coulter-allegra-x-14r-refrigerated-centrifuge","provider":"Marshall Scientific","version":"1.0","type":"link"}