{"product_id":"ge-akta-pilot-fplc-system","title":"GE AKTA Pilot FPLC System","description":"\u003cdiv class=\"productdescriptiontables\"\u003e\n\t\u003ch1\u003eGE AKTA Pilot FPLC System\u003c\/h1\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-section\"\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eFlow Rate Range\u003c\/b\u003e\u003cbr\u003e4 to 400 ml\/min (Up to 800 ml\/min in Dual-Pump Mode)\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003ePressure Range\u003c\/b\u003e\u003cbr\u003e0 to 2 MPa (20 bar, 290 psi)\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eWavelength Range \u003c\/b\u003e\u003cbr\u003e190 to 700 nm\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"features-section\"\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cspan class=\"features-header\"\u003eFeatures\u003c\/span\u003e\n\t\t\t\u003cul\u003e\n\t\t\t\t\u003cli\u003eSupports pilot-scale purification, process development, and small-scale cGMP manufacturing\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eBiocompatible, hygienic, and sterilizable to meet GLP and cGMP requirements\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eDual-module system pump enables accurate binary gradient formation\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eIntegrated air trap and air sensors protect columns by removing bubbles\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eIn-line UV, pH, and conductivity detectors with self-calibration for reliable monitoring\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eUNICORN software offers method development, real-time control, and data analysis\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eStepper-motor-actuated valves provide precise fluid routing throughout the system\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eIdeal for scaling lab processes to clinical and early production environments\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eCompatible with a wide range of chromatography columns and media types\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eTemperature-compensated pH monitoring ensures accurate readings during runs\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eDetector flow cells are positioned to minimize band broadening and signal delay\u003c\/li\u003e\n\t\t\t\t\u003cli\u003ePre-programmed method templates streamline media scouting and optimization\u003c\/li\u003e\n\t\t\t\u003c\/ul\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/GE-AKPFS_d7d850d3-193d-4547-8b03-ca03d2a6a986.jpg?v=1779990456\"\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\tThe GE AKTA Pilot FPLC System is a robust, automated liquid chromatography platform purpose-built for pilot-scale purification, process development, and small-scale biomanufacturing. Designed to bridge the gap between laboratory-scale research and production-scale workflows, the AKTA Pilot supports a wide range of applications, including method optimization, column packing, clinical trial material preparation, and early-phase cGMP manufacturing. Engineered to meet strict regulatory requirements, it is fully biocompatible, hygienic, and sterilizable, conforming to GLP (Good Laboratory Practice) and cGMP (current Good Manufacturing Practice) guidelines for use in Phases I–III of drug development.\n\t\u003cbr\u003e\u003cbr\u003e\n\tAt the heart of the system are two high-precision peristaltic pumps: the P-907 system pump and the P-908 sample pump. The P-907 pump features dual modules (A and B) to enable highly accurate binary gradient formation, while the P-908 sample pump is a single-module configuration ideal for sample loading. Both pumps incorporate pressure sensors that continuously monitor pressure levels in the flow path to ensure optimal system performance and prevent overpressure events. The system accommodates flow rates ranging from 4 to 400 ml\/min in standard operation, and up to 800 ml\/min in dual-pump mode, supporting a wide range of scale-up scenarios. With a maximum operating pressure of 2 MPa (20 bar or 290 psi), the system is compatible with both low- and high-pressure chromatography columns, offering exceptional flexibility for diverse purification strategies.\n\t\u003cbr\u003e\u003cbr\u003e\n\tThe AKTA Pilot includes a network of stepper-motor-actuated membrane valves housed within nine individually configured valve blocks, each precisely controlling liquid routing through various stages of the purification process. A sample valve enables flexible inlet selection for loading, while inlet valves guide buffer solutions through a system of pressure sensors and air management components, including an air trap and dual air sensors, to eliminate air bubbles and protect sensitive downstream components such as chromatography columns. These built-in air management features are especially useful for preventing column damage and ensuring reproducibility during scale-up operations.\n\t\u003cbr\u003e\u003cbr\u003e\n\tDownstream of the separation column(s), the system is equipped with an integrated array of detectors that provide continuous in-line monitoring of critical parameters. These include a sanitary pH electrode (range 0 to 14, validated between pH 2 and 12), a conductivity cell (range 1 uS\/cm to 999.9 mS\/cm), and a UV absorbance detector capable of monitoring up to three wavelengths simultaneously in the 190 to 700 nm range with 1 nm resolution. All detectors are self-calibrating and self-testing to ensure reliable and accurate performance. The pH and conductivity detectors are positioned in close proximity to one another, minimizing dead volume and reducing band broadening, while the conductivity cell includes a temperature sensor to enable real-time temperature compensation for pH readings. The UV cell, placed immediately downstream, enables detection of target molecules with high sensitivity and minimal delay.\n\t\u003cbr\u003e\u003cbr\u003e\n\tSystem control and data acquisition are managed through UNICORN software, a comprehensive platform that enables method development, gradient control, detector monitoring, and data analysis in a single intuitive interface. The software includes pre-configured templates for common procedures such as media scouting and pH gradient optimization, allowing users to streamline the development of purification protocols. Fraction collection is handled by outlet valves that direct purified product or waste streams based on real-time signal data, enabling highly automated workflows. The system also allows for external device integration and advanced customization for specific bioprocessing needs.\n\t\u003cbr\u003e\u003cbr\u003e\n\tWith its sanitary design, rugged construction, and advanced fluid handling capabilities, the GE AKTA Pilot FPLC System is widely regarded as the gold standard for bridging research and production. It enables rapid scale-up of laboratory-developed methods into reproducible, scalable processes for the biopharmaceutical industry. Whether you're performing purification for clinical trial batches or developing robust manufacturing protocols, the AKTA Pilot delivers the precision, control, and compliance needed for demanding bioprocess environments.\n\t\u003cbr\u003e\u003cbr\u003eAll of our equipment is fully tested to perform at factory specifications before being shipped.\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"included-box\"\u003e\n\t\t\u003cspan class=\"included-header\"\u003eINCLUDED:\u003c\/span\u003e\u003cbr\u003eThe GE AKTA Pilot FPLC System includes:\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eP-907 System Pump A\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eP-907 System Pump B\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eP-908 Sample Pump\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eIn-line UV Detector\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eIn-line Conductivity Detector\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eIn-line pH Detector\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eInlet Valve V1\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eInlet Valve V2\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eSample Valve V3\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eAir Trap Valve V4\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eFlow Direction Valve V5\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eColumn Valve V6\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eColumn Valve V7\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eOutlet Valve V8\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eOutlet Valve V9\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eMixer w\/ 5ml Chamber\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003e4 x Pressure Sensors\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003e2 x Air Sensors\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eAir Trap\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eWindows 11 Professional 64-Bit Data Station with Installed UNICORN Version 5.31 Software\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eInstallation Calibration Report\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eCommunication Cables\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eTubing, Power Cords\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eFull 180 Day Parts and Labor Warranty\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\n\t\u003ch2\u003eGE AKTA Pilot FPLC System Specifications\u003c\/h2\u003e\n\t\u003ctable\u003e\n\t\u003ctbody\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tFlow Rate Range\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t4 to 400 ml\/min\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDual-Pump Mode Maximum Flow Rate\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tUp to 800 ml\/min\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tPressure Range\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t0 to 2 MPa (20 bar, 290 psi)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tWavelength Range\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t190 to 700 nm in steps of 1 nm, 3 wavelengths simultaneously\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tConductivity Range\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t1 uS\/cm to 999.9 mS\/cm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tpH Range\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t0 to 14 (specifications valid between 2 and 12)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tMaximum Viscosity\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t5 cP\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDimensions (W x D x H)\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t29.5 x 21.3 x 35 in. (75 x 54 x 90 cm)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tWeight\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t251 lb. (114 kg)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tElectrical Requirements\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t100-240V, 50\/60Hz, 800VA\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\t\u003c\/table\u003e\n\t\u003cbr\u003e\n\t\u003ctable\u003e\n\t\u003ctbody\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd colspan=\"2\"\u003e\n\t\t\t\u003ccenter\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t\tComputer Specifications\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003c\/center\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\tProcessor\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\tIntel Core I5-8500 CPU\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\tRAM\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\t32.0 GB\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\tHard Drive\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\t500GB Internal SSD\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\tOperating System\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\tWindows 11 Professional, 64-bit\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\t\u003c\/table\u003e\n\t\u003cspan class=\"downloads-header\"\u003eDownloads\u003c\/span\u003e\n\t\u003cdiv class=\"downloads-section\"\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/GE_AKTA_Pilot_FPLC_System_-_Marshall_Scientific.pdf?v=1779990459\" target=\"blank\"\u003e\n\t\t\tTechnical Specification Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/GE_AKTA_Pilot_FPLC_System_Manual_-_Marshall_Scientific.pdf?v=1779990462\" target=\"blank\"\u003e\n\t\t\tOperator's Manual Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"formalquote2\"\u003e\n\t\t\u003ca class=\"formalquote2link\" href=\"\/formal_quote_a\/2993.htm\" target=\"blank\"\u003eRequest a Formal Quote\u003c\/a\u003e\n\t\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cspan class=\"windows11\"\u003e\u003c\/span\u003e","brand":"My Store","offers":[{"title":"Default Title","offer_id":42474810998874,"sku":"GE-AKPFS","price":49995.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/GE-AKPFS-2.jpg?v=1761223584","url":"https:\/\/p2gnpt-0c.myshopify.com\/products\/ge-akta-pilot-fplc-system","provider":"Marshall Scientific","version":"1.0","type":"link"}