{"product_id":"mj-research-ptc-200-thermal-cycler-dual-48","title":"MJ Research PTC-200 Thermal Cycler Dual 48","description":"\u003cdiv class=\"productdescriptiontables\"\u003e\n\t\u003ch1\u003eMJ Research PTC-200 Thermal Cycler Dual 48\u003c\/h1\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-section\"\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003e\n\t\t\t\tThermal Range\u003c\/b\u003e\u003cbr\u003e5C to 105C - no more than 30C below ambient\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eRamping Rate\t\u003c\/b\u003e\u003cbr\u003e 3C \/ sec\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eSample Capacity\t \u003c\/b\u003e\u003cbr\u003e\tDual 48 Well Alpha Block\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"features-section\"\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cspan class=\"features-header\"\u003eFeatures\u003c\/span\u003e\n\t\t\t\u003cul\u003e\n\t\t\t\t\u003cli\u003eDual 48-well block design allows two independent programs to run simultaneously\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eHot Bonnet heated lid controls pressure and height for oil-free cycling\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eExceptional thermal accuracy of ±0.3C at 90C ensures reliable performance\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eUnparalleled temperature uniformity of ±0.4C within 30 seconds for consistent results\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eIntuitive software with an easy-to-read 20 x 4 LCD display for seamless programming and monitoring\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eSupports calculated sample temperature control, block control, or probe control for protocol flexibility\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eInstant Incubate feature enables continuous-temperature incubations for extended applications\u003c\/li\u003e\n\t\t\t\t\n\t\t\t\t\u003cli\u003eCompact, space-saving design makes setup and transportation easy\u003c\/li\u003e\n\t\t\t\u003c\/ul\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/MJ-200D-Features_1c5249ea-f418-4604-875a-1780fb29e49a.jpg?v=1779993297\"\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv\u003e\n\t\t\u003cfont color=\"#000000\" face=\"Arial, sans-serif\"\u003eThe MJ Research PTC-200 Thermal Cycler Dual 48 utilizes interchangeable sample blocks and heat pump assemblies allow the user to change format easily between runs while retaining NIST-traceable accuracy. The PTC-200 has a \u003c\/font\u003e\u003ca href=\"https:\/\/www.marshallscientific.com\/admin\/AdminDetails_Generic.asp?table=Products_Joined\u0026amp;Page=1\u0026amp;ID=MJ-D48\" style=\"font-family: Arial;\"\u003edual 48-well alpha block\u003c\/a\u003e\u003cfont color=\"#000000\" face=\"Arial, sans-serif\"\u003e, allowing two independent programs to be run at the same time, \u003c\/font\u003e\u003cspan style=\"font-family: Arial;\"\u003eand can accommodate \u003c\/span\u003e\u003ca href=\"https:\/\/www.marshallscientific.com\/ProductDetails.asp?ProductCode=MJ-60\" style=\"font-family: Arial;\"\u003e60 well blocks\u003c\/a\u003e\u003cspan style=\"font-family: Arial;\"\u003e, \u003c\/span\u003e\u003ca href=\"https:\/\/www.marshallscientific.com\/ProductDetails.asp?ProductCode=MJ-96\" style=\"font-family: Arial;\"\u003e96 well blocks\u003c\/a\u003e\u003cspan style=\"font-family: Arial;\"\u003e, \u003c\/span\u003e\u003ca href=\"https:\/\/www.marshallscientific.com\/ProductDetails.asp?ProductCode=MJ-384\" style=\"font-family: Arial;\"\u003e384-well blocks\u003c\/a\u003e\u003cspan style=\"background-color: initial; font-family: Arial;\"\u003e, and many others, including specialty blocks like the insitu\u003c\/span\u003e\u003cspan style=\"background-color: initial; color: rgb(0, 0, 0); font-family: Arial, sans-serif;\"\u003e. The precise Peltier effect heat pumps deliver the full temperature range of 0 to 100C electronically, all in a compact, small-footprint instrument. The MJ Research PTC-200 offers speedy ramping rates of up to 3.0\/sec in models that hold 0.2ml tubes or V-well plates. It also features unparalleled temperature homogeneity of 0.4C within 30 seconds of arrival at 60C for all standard models. The PTC-200 has a large memory and amiable software that allows control over virtually every thermal parameter.\u003c\/span\u003e\n\t\t\u003cdiv\u003e\n\t\t\t\u003cfont color=\"#000000\" face=\"Arial, sans-serif\"\u003e\u003cbr\u003e\u003c\/font\u003e\n\t\t\t\u003cdiv\u003e\n\t\t\t\t\u003cfont color=\"#000000\" face=\"Arial, sans-serif\"\u003eThe MJ Research PTC-200 is in excellent condition and will be fully tested to perform at factory specifications before being shipped.\u003c\/font\u003e\n\t\t\t\t\u003cdiv\u003e\n\t\t\t\t\t\u003cfont color=\"#000000\" face=\"Arial, sans-serif\"\u003e\u003cbr\u003e\u003c\/font\u003e\n\t\t\t\t\t\u003cdiv\u003e\n\t\t\t\t\t\t\u003cfont color=\"#000000\" face=\"Arial, sans-serif\"\u003e\n\t\t\t\t\t\t\u003cdiv class=\"included-box\"\u003e\n\t\t\t\t\t\t\t\u003cspan class=\"included-header\"\u003eINCLUDED:\u003c\/span\u003e\u003cbr\u003eThe MJ Research PTC-200 Thermal Cycler Dual 48 includes:\n\t\t\t\t\t\t\t\u003cul\u003e\n\t\t\t\t\t\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003e Dual 48 Well Alpha Block\u003c\/li\u003e\n\t\t\t\t\t\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eNIST Traceable Calibration Certificate\u003c\/li\u003e\n\t\t\t\t\t\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003e Power Cord\u003c\/li\u003e\n\t\t\t\t\t\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003e Operator's Manual\u003c\/li\u003e\n\t\t\t\t\t\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003e Full 180 Day Parts and Labor Warranty\u003c\/li\u003e\n\t\t\t\t\t\t\t\u003c\/ul\u003e\n\t\t\t\t\t\t\u003c\/div\u003e\n\t\t\t\t\t\t\u003ch2\u003eMJ Research PTC-200 Thermal Cycler Dual 48 Specifications\u003c\/h2\u003e\n\t\t\t\t\t\t\u003ctable\u003e\n\t\t\t\t\t\t\u003ctbody\u003e\n\t\t\t\t\t\t\u003ctr\u003e\n\t\t\t\t\t\t\t\u003ctd\u003e\n\t\t\t\t\t\t\t\tThermal Range\n\t\t\t\t\t\t\t\u003c\/td\u003e\n\t\t\t\t\t\t\t\u003ctd\u003e\n\t\t\t\t\t\t\t\t5C to 105C, but no more than 30C below ambient temperature (4 to 100C for the slide Chambers Alpha Unit)\n\t\t\t\t\t\t\t\u003c\/td\u003e\n\t\t\t\t\t\t\u003c\/tr\u003e\n\t\t\t\t\t\t\u003ctr\u003e\n\t\t\t\t\t\t\t\u003ctd\u003e\n\t\t\t\t\t\t\t\tThermal Accuracy\n\t\t\t\t\t\t\t\u003c\/td\u003e\n\t\t\t\t\t\t\t\u003ctd\u003e\n\t\t\t\t\t\t\t\t± 0.3C of programmed target at 90C- NIST-traceable\n\t\t\t\t\t\t\t\u003c\/td\u003e\n\t\t\t\t\t\t\u003c\/tr\u003e\n\t\t\t\t\t\t\u003ctr\u003e\n\t\t\t\t\t\t\t\u003ctd\u003e\n\t\t\t\t\t\t\t\tThermal Uniformity\n\t\t\t\t\t\t\t\u003c\/td\u003e\n\t\t\t\t\t\t\t\u003ctd\u003e\n\t\t\t\t\t\t\t\t± 0.4C well-to-well within 30 seconds of arrival at 90C (for most Alpha units; see specifications for individual Alpha Units)\n\t\t\t\t\t\t\t\u003c\/td\u003e\n\t\t\t\t\t\t\u003c\/tr\u003e\n\t\t\t\t\t\t\u003ctr\u003e\n\t\t\t\t\t\t\t\u003ctd\u003e\n\t\t\t\t\t\t\t\tRamping Rate\n\t\t\t\t\t\t\t\u003c\/td\u003e\n\t\t\t\t\t\t\t\u003ctd\u003e\n\t\t\t\t\t\t\t\tUp to 3˚C\/sec for all single- and dual-block Alpha units; 1.2˚C\/sec for the Twin Tower\n\t\t\t\t\t\t\t\u003c\/td\u003e\n\t\t\t\t\t\t\u003c\/tr\u003e\n\t\t\t\t\t\t\u003ctr\u003e\n\t\t\t\t\t\t\t\u003ctd\u003e\n\t\t\t\t\t\t\t\tGradient Function\n\t\t\t\t\t\t\t\u003c\/td\u003e\n\t\t\t\t\t\t\t\u003ctd\u003e\n\t\t\t\t\t\t\t\tNo\n\t\t\t\t\t\t\t\u003c\/td\u003e\n\t\t\t\t\t\t\u003c\/tr\u003e\n\t\t\t\t\t\t\u003ctr\u003e\n\t\t\t\t\t\t\t\u003ctd\u003e\n\t\t\t\t\t\t\t\tMemory\n\t\t\t\t\t\t\t\u003c\/td\u003e\n\t\t\t\t\t\t\t\u003ctd\u003e\n\t\t\t\t\t\t\t\t200 typical programs in up to 12 individual folders\n\t\t\t\t\t\t\t\u003c\/td\u003e\n\t\t\t\t\t\t\u003c\/tr\u003e\n\t\t\t\t\t\t\u003ctr\u003e\n\t\t\t\t\t\t\t\u003ctd\u003e\n\t\t\t\t\t\t\t\tSample Capacity\n\t\t\t\t\t\t\t\u003c\/td\u003e\n\t\t\t\t\t\t\t\u003ctd\u003e\n\t\t\t\t\t\t\t\tDual 48 Well Alpha Block\n\t\t\t\t\t\t\t\u003c\/td\u003e\n\t\t\t\t\t\t\u003c\/tr\u003e\n\t\t\t\t\t\t\u003ctr\u003e\n\t\t\t\t\t\t\t\u003ctd\u003e\n\t\t\t\t\t\t\t\tParrallel\n\t\t\t\t\t\t\t\u003c\/td\u003e\n\t\t\t\t\t\t\t\u003ctd\u003e\n\t\t\t\t\t\t\t\t1x 25-pin 8-bit parallel interface printer port\n\t\t\t\t\t\t\t\u003c\/td\u003e\n\t\t\t\t\t\t\u003c\/tr\u003e\n\t\t\t\t\t\t\u003ctr\u003e\n\t\t\t\t\t\t\t\u003ctd\u003e\n\t\t\t\t\t\t\t\tSerial\n\t\t\t\t\t\t\t\u003c\/td\u003e\n\t\t\t\t\t\t\t\u003ctd\u003e\n\t\t\t\t\t\t\t\t1x 9-pin RS-232 serial port for printer or remote use\n\t\t\t\t\t\t\t\u003c\/td\u003e\n\t\t\t\t\t\t\u003c\/tr\u003e\n\t\t\t\t\t\t\u003ctr\u003e\n\t\t\t\t\t\t\t\u003ctd\u003e\n\t\t\t\t\t\t\t\tIEEE\n\t\t\t\t\t\t\t\u003c\/td\u003e\n\t\t\t\t\t\t\t\u003ctd\u003e\n\t\t\t\t\t\t\t\tone IEEE-488 bidirectional general purpose interface bus\n\t\t\t\t\t\t\t\u003c\/td\u003e\n\t\t\t\t\t\t\u003c\/tr\u003e\n\t\t\t\t\t\t\u003ctr\u003e\n\t\t\t\t\t\t\t\u003ctd\u003e\n\t\t\t\t\t\t\t\tDisplay\n\t\t\t\t\t\t\t\u003c\/td\u003e\n\t\t\t\t\t\t\t\u003ctd\u003e\n\t\t\t\t\t\t\t\tone 20 x 4 LCD alphanumeric display\n\t\t\t\t\t\t\t\u003c\/td\u003e\n\t\t\t\t\t\t\u003c\/tr\u003e\n\t\t\t\t\t\t\u003ctr\u003e\n\t\t\t\t\t\t\t\u003ctd\u003e\n\t\t\t\t\t\t\t\tDimensions (L x W x H)\n\t\t\t\t\t\t\t\u003c\/td\u003e\n\t\t\t\t\t\t\t\u003ctd\u003e\n\t\t\t\t\t\t\t\t12 x 12 x 12 in. (30.5 x 30.5 x 30.5 cm)\n\t\t\t\t\t\t\t\u003c\/td\u003e\n\t\t\t\t\t\t\u003c\/tr\u003e\n\t\t\t\t\t\t\u003ctr\u003e\n\t\t\t\t\t\t\t\u003ctd\u003e\n\t\t\t\t\t\t\t\tWeight\n\t\t\t\t\t\t\t\u003c\/td\u003e\n\t\t\t\t\t\t\t\u003ctd\u003e\n\t\t\t\t\t\t\t\t25 lb. (11.3 kg)\n\t\t\t\t\t\t\t\u003c\/td\u003e\n\t\t\t\t\t\t\u003c\/tr\u003e\n\t\t\t\t\t\t\u003ctr\u003e\n\t\t\t\t\t\t\t\u003ctd\u003e\n\t\t\t\t\t\t\t\tElectrical Requirements\n\t\t\t\t\t\t\t\u003c\/td\u003e\n\t\t\t\t\t\t\t\u003ctd\u003e\n\t\t\t\t\t\t\t\t100 - 240 VAC, 50-60Hz, 850W\n\t\t\t\t\t\t\t\u003c\/td\u003e\n\t\t\t\t\t\t\u003c\/tr\u003e\n\t\t\t\t\t\t\u003c\/tbody\u003e\n\t\t\t\t\t\t\u003c\/table\u003e\n\t\t\t\t\t\t\u003c\/font\u003e\n\t\t\t\t\t\u003c\/div\u003e\n\t\t\t\t\t\u003cfont color=\"#000000\" face=\"Arial, sans-serif\"\u003e\n\t\t\t\t\t\u003cspan class=\"downloads-header\"\u003eDownloads\u003c\/span\u003e\n\t\t\t\t\t\u003cdiv class=\"downloads-section\"\u003e\n\t\t\t\t\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\t\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/ptc-200225_eed1e779-5e71-458e-846d-5033d033a6ef.pdf?v=1779993291\" target=\"blank\"\u003e\n\t\t\t\t\t\t\tTechnical Specification Download\n\t\t\t\t\t\t\t\u003c\/a\u003e\n\t\t\t\t\t\t\u003c\/div\u003e\n\t\t\t\t\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\t\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/MJ_Research_PTC-200_and_PTC-225_Series_Thermal_Cyclers_Manual_-_Marshall_Scientific.pdf?v=1779993301\" target=\"blank\"\u003e\n\t\t\t\t\t\t\tOperator's Manual Download\n\t\t\t\t\t\t\t\u003c\/a\u003e\n\t\t\t\t\t\t\u003c\/div\u003e\n\t\t\t\t\t\u003c\/div\u003e\n\t\t\t\t\t\u003cdiv class=\"formalquote2\"\u003e\n\t\t\t\t\t\t\u003ca class=\"formalquote2link\" href=\"\/formal_quote_a\/918.htm\" target=\"blank\"\u003eRequest a Formal Quote\u003c\/a\u003e\n\t\t\t\t\t\u003c\/div\u003e\n\t\t\t\t\t\u003c\/font\u003e\n\t\t\t\t\u003c\/div\u003e\n\t\t\t\u003c\/div\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Marshall scientific","offers":[{"title":"Default Title","offer_id":42502189121626,"sku":"MJ-200D","price":3295.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/MJ-200D-2.jpg?v=1761897697","url":"https:\/\/p2gnpt-0c.myshopify.com\/products\/mj-research-ptc-200-thermal-cycler-dual-48","provider":"Marshall Scientific","version":"1.0","type":"link"}