Fisher Scientific Digital Vortexer, Cat # 0215370
The Fisher Scientific Digital Vortexer (# 0215370) is designed for gentle shaking or vigorous vortexing of samples in a wide variety of applications. Use with flasks, beakers, tubes, and microwell plates. Constructed using a heavy base casting with corrosion-resistant enamel finish, units remain stable on work surfaces. The variable speed vortex mixers are designed for high speed mixing or touch mixing for vigorous vortexing of samples.
All of our equipment is fully tested to perform at factory specifications before being shipped.
The Fisher Scientific Digital Vortexer, Cat # 0215370 includes:
- > Top
- > Power Cord
- > Operator's Guide
- > Full 180 Day Parts and Labor Warranty
Fisher Scientific Digital Vortexer Specifications
|
Speed Range |
500 to 3,000 RPM |
|
Orbit |
4.9 mm |
|
Timer |
1 sec to 9,999 min |
|
Overall Dimensions (L x W x H) |
8 x 4.25 x 5 in (20.3 x 10.8 x 12.7 cm) |
- Verify power supply and PCB output correct, stable voltages across all required circuits
- Confirm the correct platform head is installed according to specifications
- Inspect the display for dim or dead pixels, replacing any compromised sections to maintain clear visibility
- Confirm full functionality of all buttons and knobs, ensuring accurate input response
- Verify that touch, pulse, and continuous modes operate fully and as intended
- Inspect all internal wiring for breakages, tears, or wear, replacing any underperforming components to ensure reliability
- Disassemble and thoroughly clean the internal casing to remove any accumulated debris
- Check that the feet are intact and confirm the vortexer is properly balanced on a flat surface
- Conduct a comprehensive cosmetic inspection to ensure all exterior surfaces meet quality standards
Technician Inspection and Recertification Checklist: Vortexer
The Following Checklist Is to Be Performed on All Incoming and Outgoing Pieces of Equipment| Task | Completed? | Remarks? |
| Verify power supply and PCB output stable, correct voltages across circuits | Completed | |
| Confirm correct platform head is installed according to specifications | Completed | |
| Inspect display for dim or dead pixels; replace compromised sections for clarity | Completed | |
| Confirm functionality of all buttons and knobs for accurate input response | Completed | |
| Verify full operation of touch, pulse, and continuous modes as intended | Completed | |
| Inspect internal wiring for damage; replace underperforming components for reliability | Completed | |
| Disassemble and clean internal casing to remove accumulated debris | Completed | |
| Check feet for integrity and confirm vortexer is balanced on flat surface | Completed | |
| Conduct comprehensive cosmetic inspection to ensure quality of exterior surfaces | Completed |
Fisher Scientific Digital Vortexer Manual
Click Here to View all the Technical Specs for the Digital Vortexer


Click Here to View the Technical Specs for the Digital Vortexer