Fisher Vortex Genie 2 G560 Vortexer
Speed Range
600 to 3200 RPM
Orbit
4 mm
Base Dimensions (D x W x H)
6.5 x 4.8 x 6.5 in
- Variable manual speed controls for precise mixing adjustments
- Wide speed range of 600 to 3200 RPM for gentle to vigorous vortexing
- Dual operation modes with touch and automatic functionality for flexibility
- Dimpled head securely holds a variety of sample containers
- Compact and stable design ensures reliable performance during operation
- Operating temperature range of 0C to 38C for use in diverse environments
The Fisher Vortex Genie 2 G560 Vortexer includes:
- > Rubber Dimpled Head
- > Power Cord
- > Full 180 Day Parts and Labor Warranty
Fisher Vortex Genie 2 G560 Vortexer
| Speed Range | 600 to 3200 RPM |
| Orbit | 4 mm |
| Timer | N/A |
| Environmental | 0C to 38C |
| Base Dimensions (D x W x H) | 6.5 x 4.8 x 6.5 in |
| Weight | 8.8 lb. (4 kg) |
| Electrical Requirements | 120 V, 60 Hz, 0.65 amps |
- Verify power supply and PCB output correct, stable voltages across all required circuits
- Confirm the correct platform head is installed according to specifications
- Inspect the display for dim or dead pixels, replacing any compromised sections to maintain clear visibility
- Confirm full functionality of all buttons and knobs, ensuring accurate input response
- Verify that touch, pulse, and continuous modes operate fully and as intended
- Inspect all internal wiring for breakages, tears, or wear, replacing any underperforming components to ensure reliability
- Disassemble and thoroughly clean the internal casing to remove any accumulated debris
- Check that the feet are intact and confirm the vortexer is properly balanced on a flat surface
- Conduct a comprehensive cosmetic inspection to ensure all exterior surfaces meet quality standards
Technician Inspection and Recertification Checklist: Vortexer
The Following Checklist Is to Be Performed on All Incoming and Outgoing Pieces of Equipment| Task | Completed? | Remarks? |
| Verify power supply and PCB output stable, correct voltages across circuits | Completed | |
| Confirm correct platform head is installed according to specifications | Completed | |
| Inspect display for dim or dead pixels; replace compromised sections for clarity | Completed | |
| Confirm functionality of all buttons and knobs for accurate input response | Completed | |
| Verify full operation of touch, pulse, and continuous modes as intended | Completed | |
| Inspect internal wiring for damage; replace underperforming components for reliability | Completed | |
| Disassemble and clean internal casing to remove accumulated debris | Completed | |
| Check feet for integrity and confirm vortexer is balanced on flat surface | Completed | |
| Conduct comprehensive cosmetic inspection to ensure quality of exterior surfaces | Completed |


Click Here to View the Technical Specs for the Fisher Vortex Genie 2 G560