Hach TL2350 Benchtop Turbidimeter
Range
NTU (Ratio on): 0 to 10000 auto decimal
Repeatability
<500 mOsm/kg: ± 2 mOsm/kg
±1% of reading or 0.01 NTU, whichever is greater (under reference conditions)
Stabilization Time
Ratio on: 30 minutes after start-up / Ratio off: 60 minutes after start-up
- Meets EPA Method 180.1 for compliant turbidity testing in laboratory environments
- Tungsten lamp light source ensures dependable, consistent turbidity measurements
- Color touchscreen display with intuitive guided workflows for simplified operation
- Automatic sample stability detection guarantees accurate and reliable readings
- Integrated self-diagnostics maintain instrument readiness and reduce downtime
- USB data export enables fast, traceable transfer of test results
- Rugged benchtop design provides durability for demanding, high-volume lab use
- Step-by-step instructions help all users achieve consistent and reproducible results

Engineered with an intuitive full-color touchscreen interface, the TL2350 streamlines operation with guided setup, calibration, and measurement workflows that reduce training time and operator error. Automatic sample stability detection ensures every reading is taken at the optimal point, eliminating uncertainty and the need for repeated measurements. Additional convenience features—such as rapid USB data export, sample ID tracking, and integrated self-diagnostics—enhance traceability and minimize downtime. With its durable construction, user-focused design, and advanced analytical capability, the Hach TL2350 is a smart, reliable choice for laboratories seeking precise, efficient, and compliant turbidity measurement day after day.
Please Note: Instrument grade air or dry nitrogen source are required for use of air purge system and are not included with purchase.
All of our equipment is fully tested to perform at factory specifications before being shipped.
The Hach TL2350 Benchtop Turbidimeter includes:
- > Power Cord
- > Operator's Manual
- > Full 180 Day Parts and Labor Warranty
Hach TL2350 Benchtop Turbidimeter Specifications
| Range | NTU (Ratio on): 0 to 10000 auto decimal NTU (Ratio off): 0 to 40 EBC (Ratio on): 0 to 2450 auto decimal EBC (Ratio off): 0 to 9.8 Absorbance (auto range): 0 to 1.0 Transmittance (%): 1.0 to 100 Degree (mg /L): 1 to 100 |
| Reading Modes | Single, continuous, Rapidly Settling Turbidity, signal averaging on or off, ratio on or off |
| Repeatability | ±1% of reading or 0.01 NTU, whichever is greater (under reference conditions) |
| Response Time | Signal averaging off: 6.8 seconds / Signal averaging on: 14 seconds (when 10 measurements are used to calculate the average) |
| Sample Cell Compatibility | Round cells 95 x 25 mm (3.74 x 1 in.) borosilicate glass with rubber-lined screw caps Note: Smaller sample cells (less than 25 mm) can be used when a cell adapter is used. |
| Sample Requirements | 25 mm sample cell: 20 mL minimum 0 to 70 °C (32 to 158 °F) |
| Source Lamp | Tungsten Lamp |
| Stabilization Time | Ratio on: 30 minutes after start-up Ratio off: 60 minutes after start-up |
| Accuracy | Ratio on: ± 2% of reading plus 0.01 NTU from 0 to 1000 NTU, ± 5% of reading from 1000 to 4000 NTU ± 10% of reading from 4000 to 10000 NTU Ratio off: ± 2% of reading plus 0.01 NTU from 0 to 40 NTU |
| Accuracy 3 | Absorbance: ± 0.01 Abs from 0 to 0.5 Abs at 455 nm, ± 2% Abs from 0.5 to 1 Abs at 455 nm Transmittance: 2% T from 10 to 100% T at 455 nm |
| Display | 17.8 mm (7 in.) color touch screen |
| Interface | 2 USB-A ports for USB flash drive, external printer, keyboard and barcode scanner |
| Air Purge Requirements | Dry nitrogen or instrument grade air (ANSI MC 11.1, 1975) 0.1 scfm at 69 kPa (10 psig); 138 kPa (20 psig) maximum Hose barb connection for 1/8-inch tubing |
| Light Source | Tungsten filament lamp |
| Measurement Method | Nephelometric |
| Model | TL2350 EPA |
| Operating Temperature Range | 0 to 40 °C |
| Storage Conditions | -20 to 60°C |
| Units | NTU, EBC, Abs (absorbance), %T (% transmittance) and mg/L |
| Regulatory | Meets EPA Method 180.1 |
| Dimensions (W x D x H) | 15.5 x 12 x 6 in. (39.5 x 30.5 x 15.3 cm) |
| Weight | 6.6 lb. (3.0 kg) |
| Electrical Requirements | 100-240VAC, 50/60Hz, 3.4A |
Downloads


Click Here to View the Technical Specs for the Hach TL2350 Benchtop Turbidimeter