VWR GeneMate Multitube Vortexer
Speed Range
500 to 2,500 RPM
Orbit
3.6mm
Platform Size
12 x 7 in. (30.5 x 17.8 cm)
- Digital controls for precise operation and easy adjustments
- Programmable timer from 1 minute to 99 hours 59 minutes
- Designed to fit almost any tube rack for maximum versatility
- True vortex action ensures consistent mixing in every tube
- Durable construction for long-term laboratory use
- Compact design minimizes bench space while maximizing efficiency
All of our equipment is fully tested to perform at factory specifications before being shipped.
The VWR GeneMate Multitube Vortexer includes:
- > Power Cord
- > Operator's Manual
- > Full 180 Day Parts and Labor Warranty
VWR GeneMate Multitube Vortexer Specifications
| Speed Range | 500 to 2,500 RPM |
| Orbit | 3.6mm |
| Platform Size | 12 x 7 in. (30.5 x 17.8 cm) |
| Timer | 1 minute to 99 hours 59 minutes |
| Controls | Digital |
| Dimensions (W x D x H) | 15 x 9.2 x 16.5 in (38.1 x 23.4 x 41.9 cm) |
| Electrical Requirements | 100 to 240V. 50/60Hz, 1.5A |
- Verify power supply and PCB output correct, stable voltages across all required circuits
- Confirm the correct platform head is installed according to specifications
- Inspect the display for dim or dead pixels, replacing any compromised sections to maintain clear visibility
- Confirm full functionality of all buttons and knobs, ensuring accurate input response
- Verify that touch, pulse, and continuous modes operate fully and as intended
- Inspect all internal wiring for breakages, tears, or wear, replacing any underperforming components to ensure reliability
- Disassemble and thoroughly clean the internal casing to remove any accumulated debris
- Check that the feet are intact and confirm the vortexer is properly balanced on a flat surface
- Conduct a comprehensive cosmetic inspection to ensure all exterior surfaces meet quality standards
Technician Inspection and Recertification Checklist: Vortexer
The Following Checklist Is to Be Performed on All Incoming and Outgoing Pieces of Equipment| Task | Completed? | Remarks? |
| Verify power supply and PCB output stable, correct voltages across circuits | Completed | |
| Confirm correct platform head is installed according to specifications | Completed | |
| Inspect display for dim or dead pixels; replace compromised sections for clarity | Completed | |
| Confirm functionality of all buttons and knobs for accurate input response | Completed | |
| Verify full operation of touch, pulse, and continuous modes as intended | Completed | |
| Inspect internal wiring for damage; replace underperforming components for reliability | Completed | |
| Disassemble and clean internal casing to remove accumulated debris | Completed | |
| Check feet for integrity and confirm vortexer is balanced on flat surface | Completed | |
| Conduct comprehensive cosmetic inspection to ensure quality of exterior surfaces | Completed |