Agilent 1200 HPLC G1367C High Performance Autosampler SL
Injection Range
0.1 to 100 ul in 0.1 ul increments
Precision
Typically < 0.25% RSD of peak areas from 5 to 100 ul
Typically < 1% RSD of peak areas from 1 to 5 ul
Pressure Range
Up to 600 bar (8700 psi)
- Fast injection cycle times typically under 30 seconds to improve sample throughput
- Low carryover performance for reliable and reproducible analytical results
- Supports a wide range of sample viscosities for versatile application use
- Flexible sample capacity including well plates, standard vials, and Eppendorf tubes
- GLP features with early maintenance feedback and electronic records of maintenance and errors
- Integrated safety features including leak detection and safe leak handling
- Built-in error detection and display for simplified troubleshooting
Built with reliability and compliance in mind, the Agilent 1200 HPLC G1367C High Performance Autosampler SL includes GLP-focused features such as early maintenance feedback and electronic tracking of maintenance and errors. Safety features like leak detection, safe leak handling, and low-voltage maintenance areas provide added protection during operation. Combined with fast injection cycles and robust performance, this autosampler is well-suited for laboratories requiring high precision, efficiency, and dependable operation.
All of our equipment is fully tested to perform at factory specifications before being shipped.
The Agilent 1200 HPLC G1367C High Performance Autosampler SL includes:
- > Firmware Version 07.02 (Can be changed upon request)
- > Vial Tray
- > Lab Advisor Documentation
- > Lan Cable / Power Cord
- > Operator's Manual
- > Full 180 Day Parts and Labor Warranty
Agilent 1200 HPLC G1367C High Performance Autosampler SL Specifications
| Pressure | Up to 600 bar (8700 psi) |
| GLP Features | Early maintenance feedback (EMF), electronic records of maintenance and errors |
| Communications | Controller-area network (CAN). RS232C, APG-remote standard, optional four external contact closures and BCD vial number output |
| Safety Features | Leak detection and safe leak handling, low voltages in maintenance areas, error detection and display |
| Injection Range | 0.1 to 100 ul in 0.1 ul increments |
| Precision |
Typically < 0.25% RSD of peak areas from 5 to 100 ul
Typically < 1% RSD of peak areas from 1 to 5 ul |
| Carryover |
Typically < 0.01 % using the following conditions: Column: 125 x 4 mm Hypersil ODS, 5 µm
Mobile phase: Water/Acetonitrile = 80/20 Flow rate: 1 ml/min Injection volume: 1 ul caffeine (1 mg/ml), 5 µl water to test carryover Outside wash of needle before injection: 20 sec with water using flush port |
| Sample Viscosity Range | 0.2 to 50 cp |
| Sample Capacity |
2 × well plates (MTP) + 10 × 2 ml vials
108 x 2-mL vials in 2 x 54 vial plate plus 10 additional 2 mL vials 30 x 6-mL vials in 2 x 15 vial plate plus 10 additional 2 mL vials 54 Eppendorf tubes (0.5/1.5/2.0mL) in 2 x 27 Eppendorf tube plate |
| Injection Cycle Time |
Typically < 30 s using following standard conditions:
Default draw speed: 200 ul/min Default eject speed: 200 ul/min Injection volume: 5 ul |
| Ambient Operating Temperature | 4 to 55°C (41 to 131°F) |
| Dimensions (H x W x D) | 13.5 x 17 x 8 in. (34.5 x 44 x 20 cm) |
| Weight | 34.2 lbs. (15.5 kg) |
| Electrical Requirements | 100-120V / 220-240V, 50/60Hz |

Click Here to View the Technical Specs for the Agilent 1200 HPLC G1367C High Performance Autosampler SL