Agilent 1260 Infinity I HPLC G1314F VWD Detector
Wavelength Range (DAD)
190 - 600 nm
Noise
< ± 0.25 x 10-5 AU, at 230 nm
Drift
1 x 10-4 AU/hr, at 230 nm
- Double-beam photometer with deuterium lamp for reliable detection
- Time-programmable control of wavelength, polarity, peak width, and lamp settings
- 80 Hz data acquisition rate for improved resolution in fast LC analyses
- Wide linear range for simultaneous quantification of primary compounds, by-products, and impurities
- Stop-flow wavelength scanning for quick wavelength optimization
- RFID-enabled flow cells and lamps for enhanced traceability and easy tracking
- Automatic wavelength verification with built-in holmium oxide filter
- Extensive diagnostics and error detection via Instant Pilot controller and Lab Advisor software
- Early maintenance feedback (EMF) with lamp usage tracking and alerts
- Front access to lamps and flow cells for simplified maintenance and reduced downtime
All of our equipment is in excellent condition and will be fully tested to perform at factory specifications before being shipped.
The Agilent 1260 Infinity I HPLC G1314F VWD Detector includes:
- > Firmware Version 07.02 (Can be changed upon request)
- > Flow Cell
- > Deuterium Lamp
- > Lab Advisor Calibration Report
- > Lan Cable / Power Cord
- > Operator's Guide
- > Full 180 Day Parts and Labor Warranty
Agilent 1260 Infinity I HPLC G1314F VWD Detector Specifications
|
Detection Type |
Double-beam photometer |
| Light Source | Deuterium lamp |
| Wavelength Range | 190 - 600 nm |
| Noise | < ± 0.25 x 10-5 AU, at 230 nm |
| Drift | 1 x 10-4 AU/hr, at 230 nm |
| Linearity | >2.5 AU upper limit |
| Wavelength Accuracy | ± 1 nm, self-calibration with deuterium lines, verification with holmium oxide filter |
| Wavelength Precision | < ± 0.1 nm |
| Slit Width | 6.5nm typical over whole wavelength range |
| Time Programmable | Wavelength, polarity, peak width, lamp on/off |
| Flow Cell | Standard: 14 µL volume, 10 mm cell path length and 40 bar (580 psi) pressure maximum |
| Spectral Tools | Stop-flow wavelength scan |
| Dimensions (H x W x D) | 5.5 x 13.5 x 17 in. (14 x 34.5 x 43.6 cm) |
| Weight | 24.3 lb. (11 kg) |
| Electrical Requirements | 100-240V, 50/60Hz, 80VA |


Click Here to View the Technical Specs for the Agilent 1260 Infinity I HPLC G1314F VWD Detector