Agilent 1260 Infinity II HPLC G7129A Vialsampler
Injection Range
0.1 – 100 uL in 0.1 uL increments with 100 uL up to 60 MPa
Precision
< 0.25 % RSD of peak areas from 5 uL to 100 uL
Pressure Range
0 – 60 MPa (0 – 600 bar, 0 – 8702 psi)
- High-capacity autosampler designed for routine LC workflows
- Supports reliable and reproducible sample introduction
- Dual vial drawer design accommodates large sample sets
- Robotic gripper arm ensures precise and flexible vial handling
- Needle wash reduces carryover between injections
- Overlapped injection capability improves sample throughput
- Customizable injection programs support advanced sample handling steps
- Low internal volume minimizes contribution to system dispersion
- Compatible with Agilent InfinityLab LC systems and standard control software
Designed for integration within Agilent InfinityLab LC systems, the G7129A features a low internal volume that minimizes contribution to overall system dispersion, helping preserve chromatographic performance and reproducibility. For temperature-sensitive applications, optional thermostatted modules support precise temperature control to maintain sample integrity throughout analysis.
All of our equipment is fully tested to perform at factory specifications before being shipped.
The Agilent 1260 Infinity II HPLC G7129A Vialsampler includes:
- > Firmware Version 07.02 (Can be changed upon request)
- > Front Cover
- > Two 66 x 2 mL Vial Trays
- > Power Cord
- > Operator's Manual
- > Lab Advisor Documentation
- > Full 180 Day Parts and Labor Warranty
Agilent 1260 Infinity II HPLC G7129A Vialsampler Specifications
| Pressure | 0 – 60 MPa (0 – 600 bar, 0 – 8702 psi) |
| GLP Features | Early maintenance feedback (EMF) for continuous tracking of instrument usage with user-settable limits and feedback messages. Electronic records of maintenance and errors |
| Communications |
Controller Area Network (CAN), Local Area Network (LAN)
ERI: ready, start, stop and shut-down signals |
| Safety Features | Leak detection, safe leak handling, leak output signal for shutdown of pumping system, and low voltages in major maintenance areas |
| Injection Range | 0.1 – 100 uL in 0.1 uL increments with 100 uL up to 60 MPa |
| Precision | < 0.25 % RSD of peak areas from 5 uL to 100 uL |
| Carryover | Typically < 0.004% with needle wash |
| Sample Viscosity Range | 0.2 to 5 cP |
| Sample Capacity |
132 x 2 ml vials
100 x 2 mL vials 36 x 6 mL vials |
| Injection Cycle Time | Typically 18 s for draw speed 200 uL/min and injections volume of 1 uL |
| Ambient Operating Temperature | 4 to 55°C |
| Dimensions (W x D x H) | 15.6 x 18.4 x 12.8 in. (39.6 x 46.8 x 32 cm) |
| Weight | 41.9 lb. (19 kg) |
| Electrical Requirements | 100-240V, 50/60Hz, 350VA |


Click Here to View the Technical Specs for the Agilent 1260 Infinity II HPLC G7129A Vialsampler