Eppendorf 5452 Minispin Centrifuge
Maximum RCF
12,100 x g
Maximum Speed
13,400 RPM
Maximum Capacity
12 x 1.5/2.0 ml
- Lightweight and transportable design ideal for any laboratory setting
- Compact size fits into nearly any lab or personal workstation
- Extremely quiet centrifugal motor for reduced run noise
- Excellent air flow minimizes heat buildup during spinning
- Automatic open at the end of the run reduces handling time
- Programmable timer from 15 seconds to 30 minutes for versatile operation
- Compact dimensions of 8.9" W x 9.4" H x 4.7" L and lightweight at 9.8 lbs for easy portability
All of our equipment is fully tested to perform at factory specifications before being shipped.
The Eppendorf 5452 Minispin Centrifuge includes:
- > F-45-12-11 Rotor & Lid
- > NIST Centrifuge Calibration and Preventative Maintenance Report
- > Operator's Guide
- > Power Cord
- > Full 180 Day Parts and Labor Warranty
Eppendorf 5452 Minispin Centrifuge Specifications
|
Maximum Speed
|
13,400 rpm
|
|
Maximum RCF
|
12,100 x g
|
|
Maximum Capacity
|
12 x 1.5/2.0ml
|
|
Timer |
15 sec to 30 min
|
|
Dimensions
|
8.9 W x 9.4 H x 4.7 L in.
|
|
Weight
|
9.8 lbs
|
|
Noise Level
|
Under 49 dBa
|
|
Electrical
|
120V/50-60Hz
|
| Refrigeration | No Refrigeration |
- Confirm the power supply output voltages match specified requirements for stable distribution to all internal components
- Measure and verify voltages at PCB test points to ensure accurate power delivery and circuit integrity
- Confirm rotor compatibility with the centrifuge model and check that rotor detection systems recognize the rotor type
- Inspect the exterior for any cosmetic or structural damage that could affect performance or safety
- Check the door mechanism alignment to ensure secure and smooth opening and closing
- Inspect and replace the gas strut with an OEM part to maintain proper door support and safety
- Examine the rotor chamber bowl for dents or damage and replace as needed to ensure safe operation
- Replace and confirm full functionality of all lid lock switches to maintain secure closure
- Inspect and lubricate the door lock mechanism, applying grease to the lid lock rail for smooth operation
- Test compressor functionality (if applicable) to ensure proper operation and consistent temperature control
- Conduct an 8-12 hour cycle test to validate consistent performance over prolonged use
- Confirm rotor motor stability, check for unusual noise, and assess mechanical integrity during operation
- Inspect the condensation drain and clear any clogs to prevent moisture buildup in the rotor chamber
- Verify RPM accuracy using an NIST-traceable tachometer and perform calibration as necessary
- Check the centrifuge error log to ensure zero recorded issues, confirming system reliability
Technician Inspection and Recertification Checklist: Centrifuges
The Following Checklist Is to Be Performed on All Incoming and Outgoing Pieces of Equipment| Task | Completed? | Remarks? |
| Confirm power supply output voltages match specified requirements | Completed | |
| Measure and verify voltages at PCB test points for accuracy | Completed | |
| Confirm rotor compatibility and detection for proper identification | Completed | |
| Inspect exterior for cosmetic or structural damage | Completed | |
| Check door mechanism alignment for secure opening and closing | Completed | |
| Inspect and replace gas strut with OEM part as needed | Completed | |
| Examine rotor chamber for dents or damage and replace if necessary | Completed | |
| Replace and confirm functionality of all lid lock switches | Completed | |
| Lubricate door lock mechanism and lid lock rail for smooth operation | Completed | |
| Test compressor (if applicable) for proper operation and cooling | Completed | |
| Run 8-12 hour cycle test to ensure consistent performance | Completed | |
| Check rotor motor for stability, noise, and integrity | Completed | |
| Inspect and clear condensation drain to prevent buildup | Completed | |
| Verify RPM accuracy with NIST traceable tachometer and calibrate | Completed | |
| Check centrifuge error log for zero recorded issues | Completed |
Preventative Maintenance Performed on The Eppendorf 5452 Minispin Centrifuge
- Door Latch Assembly Checked for Full Function
- Door Hinges are Checked and Lubed as Needed
- Drive Belt is Checked for Rips and Tears and Replaced if Needed
- Rotors and O-rings are Lubed as Needed
- Lamps and Display are Checked and Replaced if Dim
- Line Cord is Checked for Signs of Fray or Damage and Replaced Accordingly
- Internal Circuitry is Checked for Faulty/Shorted Components and Replaced Accordingly
Downloads



Click Here to View the Technical Specs for the 5452 Minispin