Gilson MyPIPETMAN Select P5000, 500-5000 uL Pipette
Volume Range
500 to 5000 uL
Pipette Type
Manual Air Displacement
Number of Channels
Single
- Designed to be ergonomic, safe, and reliable while remaining lightweight and well-balanced
- Elegant design with textured effect for better grip
- Trilock volume-locking system enables users to choose different positions when setting the volume
- Fully autoclavable without disassembly for maximum convenience and protection from contamination
- Complies with the requirements of the ISO 8655 standard
All of our equipment is fully tested to perform at factory specifications before being shipped.
The Gilson MyPIPETMAN Select P5000, 500-5000 uL Pipette includes:
- > Safety Bag
- > Operator's Manual
- > Manufacturer's Documentation
- > Full 180 Day Parts and Labor Warranty
Gilson MyPIPETMAN Select P5000, 500-5000 uL Pipette Specifications
|
Volume uL |
Increment uL |
Relative Accuracy (%) |
Absolute Accuracy (uL) |
Relative Precision (%) |
Absolute Precision (uL) |
|
500 2500 5000 |
2 2 2 |
± 2.4 ± 0.6 ± 0.6 |
± 12 ± 15 ± 30 |
≤ 0.6 ≤ 0.2 ≤ 0.16 |
≤ 3 ≤ 5 ≤ 8 |
- Thoroughly inspect and clean all internal components, identifying and replacing any damaged or compromised parts
- Replace all essential wear components, including O-rings, seals, tip holders, and friction rings, to ensure optimal performance
- Examine plunger and seal holders for signs of rust, wear, or damage, replacing components as necessary for operational integrity
- Verify that no leakage is present by aspirating a sample and observing for any fluid loss
- Confirm that the Mettler Toledo AB104-S balance is precisely calibrated for accurate pipette calibration measurements
- Perform a detailed gravimetric calibration, recording all findings in the comprehensive calibration report
- Ensure that all external parts are meticulously cleaned and free from any foreign contaminants
- Test the tip ejector for smooth and reliable operation, addressing any misalignment or obstruction
- Affix a dated calibration sticker to indicate recent and verified calibration
- Conduct a detailed cosmetic inspection, confirming that all surfaces and finishes meet established quality and aesthetic standards
Technician Inspection and Recertification Checklist: Pipettes
The Following Checklist Is to Be Performed on All Incoming and Outgoing Pieces of Equipment| Task | Completed? | Remarks? |
| Thoroughly inspect and clean all internal components; replace damaged parts | Completed | |
| Replace essential wear components like O-rings, seals, and friction rings | Completed | |
| Examine plunger and seal holders for wear or damage; replace if needed | Completed | |
| Verify no leakage is present by aspirating sample and checking for fluid loss | Completed | |
| Confirm Mettler Toledo AB104-S balance calibration for accurate measurements | Completed | |
| Perform detailed gravimetric calibration and record findings in report | Completed | |
| Clean all external parts meticulously to remove any contaminants | Completed | |
| Test tip ejector for smooth, reliable operation; correct misalignments | Completed | |
| Affix dated calibration sticker to indicate verified calibration | Completed | |
| Conduct cosmetic inspection to ensure quality of surfaces and finishes | Completed |


Click Here to View the Technical Specs for the Gilson MyPIPETMAN Select P5000, 500-5000 uL Pipette