Heidolph Titramax 1000 Vibrating Shaker w/ Heating Module and Flat Incubator Hood
Speed Range
150 to 1,350 RPM
Temperature Range
Ambient +5°C to 65°C
Temperature Accuracy
± 2°C up to 50°C
± 4°C from 50°C to 65°C
- Vibrating platform shaker with integrated heating module for versatile applications
- Compact flat incubator hood made from transparent, non-fogging PETG material for clear sample visibility
- Insulated system prevents heat transfer from the motor, maintaining sample integrity
- Process timer with acoustic alarm ensures precise shaking durations up to 120 minutes
- Orbit size of 1.5 mm supports effective sample agitation
- Spacious platform measuring 11.4 x 10.2 in. for microtiter plates and other sample containers
- Durable design with a load capacity of 5kg for medium-sized experiments
- Lightweight construction with an overall weight of 23.6 lb. (10.7 kg)
- Compact footprint with overall dimensions of 19.3 x 19.7 x 21.2 in. for easy lab integration
- Operates on 115V, 50/60Hz, 360W for energy efficiency
Users can also manage shaking durations with its process timer that ranges from 1 to 120 minutes. Upon reaching the set time, an acoustic alarm notifies the user, and the shaker ceases operation. The speed is adjustable from 150 to 1,350 RPM and provides flexibility based on the nature of the sample. Accompanying the shaker is a compact incubator hood, standing at 163mm tall. This hood, tailored for microtiter plates, is crafted from a transparent, non-fogging PETG material, allowing clear visibility of samples while being straightforward to clean.
All of our equipment is in excellent condition and will be fully tested to perform at factory specifications before being shipped.
The Heidolph Titramax 1000 Vibrating Shaker w/ Heating Module and Flat Incubator Hood includes:
- > 11.4" x 10.2" Microplate Platform
- > Incubator 1000 Heating Module
- > Incubator 1000 Flat Hood
- > NIST Calibration and Preventative Maintenance Report
- > Power Cord
- > Operator's Manual
- > Full 180 Day Parts and Labor Warranty
Heidolph Titramax 1000 Vibrating Shaker w/ Heating Module and Flat Incubator Hood Specifications
| Speed Range | 150 to 1,350 RPM |
| Shaking Motion | Vibrating |
| Temperature Range | Ambient +5°C to 65°C |
| Temperature Accuracy |
± 2°C up to 50°C ± 4°C from 50°C to 65°C |
| Timer | Up to 120 minutes |
| Orbit Size | 1.5 mm (0.06 in) |
| Platform Size | 11.4 x 10.2 in. (29 x 25.9 cm) |
| Chamber Dimensions (W x D x H) | 11.4 x 10.2 x 6.4 in. (29 x 25.9 x 16.3 cm) |
| Overall Dimensions (W x D x H) | 19.3 x 19.7 x 21.2 in. (49 x 50 x 53.8 cm) |
| Weight | 23.6 lb. (10.7 kg) |
| Electrical Requirements | 115V, 50/60Hz, 360W |
- Inspect Chamber Glass for Cracks or Chips and Replace as Needed
- Inspect Door Seals and Replace as Needed
- Inspect Display and Replace Any Dim/Dead Pixels
- Confirm Full Functionality of All Buttons
- Replace All Platform Assembly Bearings
- Inspect Drive Belt and Replace If Torn or Cracked
- Inspect All Wiring for Frays, Tears, Or Breakages
- Check All PCB Test Points and Replace Any Malfunctioning Components
- Confirm Correct Tension on Drive Belt
- Confirm Compressor Functionality and Clean Condenser Filter/Fins
- Calibrate Internal Temperature with NIST Temperature Probe
- Calibrate Platform RPM’s with NIST Tachometer
- Ensure Cosmetics Are Acceptable


Click Here to View the Technical Specs for the Heidolph Titramax 1000 Vibrating Shaker w/ Heating Module and Flat Incubator Hood