Hermle Z207-H Centrifuge w/ 221.60 V01 Rotor
Maximum Speed
13,000 RPM
Maximum Capacity
24 x capillaries
Maximum RCF
16,058 x g
- Compact design ideal for laboratories with limited space
- Equipped with a hematocrit rotor accommodating 24 capillaries for efficient sample processing
- EZ-Scroll touchpad and advanced microprocessor control for easy operation and precise settings
- Programmable operation with storage for up to 99 user defined protocols
- Adjustable acceleration and deceleration rates for optimized performance
- Customizable end-of-run alarm tone for user convenience
- Momentary spin function allows quick spins with the press of a button
- Energy-saving sleep mode automatically powers down when idle, reducing energy consumption
- Displays rotational speed in RPM or RCF for flexible operation
All of our equipment is fully tested to perform at factory specifications before being shipped.
The Hermle Z207-H Centrifuge w/ 221.60 V01 Rotor includes:
- > Hermle 221.60 V01 Capillary Rotor
- > NIST Centrifuge Calibration and Preventative Maintenance Report
- > Power Cord
- > Operator's Manual
- > Full 180 Day Parts and Labor Warranty
Hermle Z207-H Centrifuge w/ 221.60 V01 Rotor Specifications
| Maximum Speed | 13,000 RPM |
| Maximum RCF | 16,058 x g |
| Maximum Capacity | 24 x capillaries |
| Temperature Range | N/A |
| Timer |
59 min 50 sec / 10 sec increments
99 h 59 min / 1 min increments |
| Acceleration Rates | 10 |
| Deceleration Rates | 10 |
| Drive System | Maintenance Free Induction Motor |
| Lid Lock | Motor Driven |
| Display | LCD |
| Program Storage | 99 Programs |
| Noise Level | < 60 dBA |
| Dimensions (W x D x H) | 11 x 13.7 x 9.5 in. (28 x 35 x 24 cm) |
| Weight | 27.5 lb. (12.5 kg) |
| Electrical Requirements | 120V, 50/60Hz, 1.7A, 150W |
| Refrigeration | No Refrigeration |
- Confirm the power supply output voltages match specified requirements for stable distribution to all internal components
- Measure and verify voltages at PCB test points to ensure accurate power delivery and circuit integrity
- Confirm rotor compatibility with the centrifuge model and check that rotor detection systems recognize the rotor type
- Inspect the exterior for any cosmetic or structural damage that could affect performance or safety
- Check the door mechanism alignment to ensure secure and smooth opening and closing
- Inspect and replace the gas strut with an OEM part to maintain proper door support and safety
- Examine the rotor chamber bowl for dents or damage and replace as needed to ensure safe operation
- Replace and confirm full functionality of all lid lock switches to maintain secure closure
- Inspect and lubricate the door lock mechanism, applying grease to the lid lock rail for smooth operation
- Test compressor functionality (if applicable) to ensure proper operation and consistent temperature control
- Conduct an 8-12 hour cycle test to validate consistent performance over prolonged use
- Confirm rotor motor stability, check for unusual noise, and assess mechanical integrity during operation
- Inspect the condensation drain and clear any clogs to prevent moisture buildup in the rotor chamber
- Verify RPM accuracy using an NIST-traceable tachometer and perform calibration as necessary
- Check the centrifuge error log to ensure zero recorded issues, confirming system reliability
Technician Inspection and Recertification Checklist: Centrifuges
The Following Checklist Is to Be Performed on All Incoming and Outgoing Pieces of Equipment| Task | Completed? | Remarks? |
| Confirm power supply output voltages match specified requirements | Completed | |
| Measure and verify voltages at PCB test points for accuracy | Completed | |
| Confirm rotor compatibility and detection for proper identification | Completed | |
| Inspect exterior for cosmetic or structural damage | Completed | |
| Check door mechanism alignment for secure opening and closing | Completed | |
| Inspect and replace gas strut with OEM part as needed | Completed | |
| Examine rotor chamber for dents or damage and replace if necessary | Completed | |
| Replace and confirm functionality of all lid lock switches | Completed | |
| Lubricate door lock mechanism and lid lock rail for smooth operation | Completed | |
| Test compressor (if applicable) for proper operation and cooling | Completed | |
| Run 8-12 hour cycle test to ensure consistent performance | Completed | |
| Check rotor motor for stability, noise, and integrity | Completed | |
| Inspect and clear condensation drain to prevent buildup | Completed | |
| Verify RPM accuracy with NIST traceable tachometer and calibrate | Completed | |
| Check centrifuge error log for zero recorded issues | Completed |
Preventative Maintenance Performed on The Hermle Z216 MK Refrigerated Centrifuge
- Door Latch Assembly Checked for Full Function
- Door Hinges are Checked and Lubed as Needed
- Drive Belt is Checked for Rips and Tears and Replaced if Needed
- Rotors and O-rings are Lubed as Needed
- Lamps and Display are Checked and Replaced if Dim
- Line Cord is Checked for Signs of Fray or Damage and Replaced Accordingly
- Internal Circuitry is Checked for Faulty/Shorted Components and Replaced Accordingly


Click Here to View the Technical Specs for the Hermle Z207-H Centrifuge w/ 221.60 V01 Rotor