Hettich Rotina 380 Benchtop Centrifuge
Max Capacity
4 x 290 mL
Max Range
15000
Max Range
24,400 x g
- Ideal benchtop centrifuge for most clinical, research and industrial laboratories.
- Adjustable RPM from 50 to 15,000 in increments of 10.
- Adjustable RCF from 50 - 24,400 in increments of 1.
- Max capacity of 4 x 290 ml, with 8 rotor options.
- Max. noise level of 54 dB(A) with rotor 1760.
- Easy operation with keypad and control knob.
- 98 program memories for more individuality.
- 9 individual acceleration and 10 deceleration stages.
The Hettich Rotina 380 Centrifuge with swing bucket rotor and buckets is a general purpose model capable of high capacity while having a small footprint in the lab. The Rotina 380 maintains quiet operation all within a user-friendly design featuring enhanced safety measures.
The Hettich Rotina 380 is ideal for clinical, research, food and beverage, and industrial applications and is capable of handling blood, cell/tissue cultures, plates, or bottles.
All of our equipment is fully tested to perform at factory specifications before being shipped.
The Hettich Rotina 380 Benchtop Centrifuge includes:
- > Hettich 1798 Rotina Swing Bucket Rotor and Buckets (No Adapters Included)
- > NIST Centrifuge Calibration and Preventative Maintenance Report
- > Power Cord
- > Operator's Guide
- > Full 180 Day Parts and Labor Warranty
Hettich Rotina 380 Benchtop Centrifuge Specifications
|
Max Capacity |
4 x 290 mL |
|
Max RPM |
15,000 |
|
Max RCF |
24,400 x g |
|
Dimensions (H x W x D) |
16.4 x 18 x 23.6 in |
| Refrigeration | No Refrigeration |
- Confirm the power supply output voltages match specified requirements for stable distribution to all internal components
- Measure and verify voltages at PCB test points to ensure accurate power delivery and circuit integrity
- Confirm rotor compatibility with the centrifuge model and check that rotor detection systems recognize the rotor type
- Inspect the exterior for any cosmetic or structural damage that could affect performance or safety
- Check the door mechanism alignment to ensure secure and smooth opening and closing
- Inspect and replace the gas strut with an OEM part to maintain proper door support and safety
- Examine the rotor chamber bowl for dents or damage and replace as needed to ensure safe operation
- Replace and confirm full functionality of all lid lock switches to maintain secure closure
- Inspect and lubricate the door lock mechanism, applying grease to the lid lock rail for smooth operation
- Test compressor functionality (if applicable) to ensure proper operation and consistent temperature control
- Conduct an 8-12 hour cycle test to validate consistent performance over prolonged use
- Confirm rotor motor stability, check for unusual noise, and assess mechanical integrity during operation
- Inspect the condensation drain and clear any clogs to prevent moisture buildup in the rotor chamber
- Verify RPM accuracy using an NIST-traceable tachometer and perform calibration as necessary
- Check the centrifuge error log to ensure zero recorded issues, confirming system reliability
Technician Inspection and Recertification Checklist: Centrifuges
The Following Checklist Is to Be Performed on All Incoming and Outgoing Pieces of Equipment| Task | Completed? | Remarks? |
| Confirm power supply output voltages match specified requirements | Completed | |
| Measure and verify voltages at PCB test points for accuracy | Completed | |
| Confirm rotor compatibility and detection for proper identification | Completed | |
| Inspect exterior for cosmetic or structural damage | Completed | |
| Check door mechanism alignment for secure opening and closing | Completed | |
| Inspect and replace gas strut with OEM part as needed | Completed | |
| Examine rotor chamber for dents or damage and replace if necessary | Completed | |
| Replace and confirm functionality of all lid lock switches | Completed | |
| Lubricate door lock mechanism and lid lock rail for smooth operation | Completed | |
| Test compressor (if applicable) for proper operation and cooling | Completed | |
| Run 8-12 hour cycle test to ensure consistent performance | Completed | |
| Check rotor motor for stability, noise, and integrity | Completed | |
| Inspect and clear condensation drain to prevent buildup | Completed | |
| Verify RPM accuracy with NIST traceable tachometer and calibrate | Completed | |
| Check centrifuge error log for zero recorded issues | Completed |
Preventative Maintenance Performed on The Hettich Rotina 380 Benchtop Centrifuge
- Door Latch Assembly Checked for Full Function
- Door Hinges are Checked and Lubed as Needed
- Drive Belt is Checked for Rips and Tears and Replaced if Needed
- Rotors and O-rings are Lubed as Needed
- Lamps and Display are Checked and Replaced if Dim
- Line Cord is Checked for Signs of Fray or Damage and Replaced Accordingly
- Internal Circuitry is Checked for Faulty/Shorted Components and Replaced Accordingly
Hettich Rotina 380 Manual
Click Here to View all the Technical Specs for the Rotina 380



Click Here to View the Technical Specs for the Rotina 380