Metrohm 899 Coulometer
Generator Electrode Output
Auto variable DC or pulsating DC at 100, 200, 400 mA
Temperature Measuring Range
–150 to +250°C
Stirrer Speed Range
Approx. 1700 to 1900 rpm, 15 steps
- Compact footprint—smaller than a sheet of A4 paper for efficient lab bench use
- Ideal for determining trace water content in liquids, solids, and gases
- No titer determination required due to absolute measurement method
- Integrated magnetic stirrer eliminates the need for external accessories
- Supports Ipol measuring mode with adjustable polarization current
- Includes indicator and generator electrodes without diaphragm
- User-friendly interface with Mini DIN, USB OTG, and Remote connectivity
- GLP-compliant with adjustable parameters and precise calibration support
- Durable PBT housing with stainless steel base ensures long-lasting performance
The Metrohm 899 Coulometer is a compact, high-precision instrument designed for trace-level water content analysis in liquids, solids, and gases. Despite its small footprint, it integrates a powerful coulometric system with an internal magnetic stirrer, making it ideal for labs where space is limited. The system includes both an indicator and generator electrode (without diaphragm) and supports a recommended measuring range of 10 µg to 200 mg of water, eliminating the need for titer determination due to its absolute measurement method. The intuitive Ipol measuring mode, precise temperature monitoring, and user-friendly interface make the 899 Coulometer a dependable tool for consistent and accurate moisture determination.
All of our equipment is fully tested to perform at factory specifications before being shipped.
The Metrohm 899 Coulometer includes:
- > Titration Cell
- > Remote
- > Power Cord
- > Operator's Manual
- > Full 180 Day Parts and Labor Warranty
Metrohm 899 Coulometer Specifications
| Measuring Mode | Ipol (adjustable polarization current) |
| Polarization Current | 5, 10, 20, or 30 uA |
| Generator Electrode Output | Auto variable DC or pulsating DC at 100, 200, 400 mA |
| Maximum Generator Current | 400 mA |
| Temperature Sensor Type | Pt1000 |
| Temperature Measuring Range | –150 to +250°C |
| Temperature Accuracy | ± 0.2°C (–20 to +150°C) |
| Stirrer Speed Range | Approx. 1700 to 1900 rpm, 15 steps |
| Housing Material | PBT (base: stainless steel 1.4301) |
| Ambient Operating Range | +5 to +45°C, max 85% humidity |
| Storage Temperature | –20 to +60°C |
| Interfaces | MSB (Mini DIN), USB OTG, Remote |
| Dimensions (W x D x H with holder) | 5.7 x 11.1 x 7.7 in. (14.4 x 28.2 x 19.5 cm) |
| Weight | 6.17 lb. (2.8 kg) |
| Electrical Requirements | 24 V DC (external power supply, input 20–28 V, max 36 W) |
Downloads


Click Here to View the Technical Specs for the Metrohm 899 Coulometer