New Brunswick Innova 2100 Orbital Shaker
The New Brunswick Scientific Innova 2100 Platform Shaker is in excellent condition and comes with a recertified platform. The Innova 2100 microprocessor controls allow for uniform motion and accurate regulation of shaking speed. Audible and visual alarms come standard with built-in timer. Shaking speeds from 250 to 500 RPM with 1 RPM speed control.
All of our equipment will be fully tested to perform at factory specifications before being shipped.
The New Brunswick Innova 2100 Orbital Shaker includes:
- > 18" x 18" Platform
- > NIST Calibration and Preventative Maintenance Report
- > Power Cord
- > Operator's Manual
- > Full 180 Day Parts and Labor Warranty
New Brunswick Innova 2100 Shaker Specifications
|
Speed
Range
|
25
to 500 RPM
|
|
Speed
Control
|
1 RPM
|
|
Timer
|
0.1
to 99.9 hours
|
|
Balanced
Drive Mechanism
|
Triple-eccentric
with permanently lubricated ball bearings
|
|
Motor
Type
|
Solid
state, DC brushless motor
|
|
Orbit
|
1.9
cm (0.75 in)
|
|
Platform
Size
|
46
x 46 cm (18 x 18 in)
|
|
Overall
Dimensions (W x D x H)
|
48
x 55.5 x 16.3 cm (19 x 21.9 x 6.4 in)
|
|
Power
Supply
|
120V,
50/60Hz
|
- Validate that the power supply and PCB deliver stable, correct voltage outputs across all necessary connections, ensuring reliable operation
- Thoroughly inspect the display for any dim, flickering, or dead pixels; replace affected elements to maintain full readability and operational clarity
- Test the full range of button functionality, confirming responsive, accurate input recognition across all settings
- Conduct a detailed inspection of bearings and bearing housing, identifying any worn or damaged bearings, and replace as needed to prevent operational disruption
- Examine the drive belt for signs of cracking, fraying, or material breakdown; replace as required to ensure sustained performance
- Measure and adjust motor drive belt tension to optimal specifications, securing reliable and efficient power transmission
- Verify accuracy of the onboard timer, confirming proper functionality and replacing if it deviates from expected performance
- Calibrate shaker rotation speed with a NIST-traceable tachometer, validating precision within specified operational limits
- Run the shaker continuously for an 8-12 hour testing period, closely observing the shaking platform for smooth, consistent motion, while monitoring for any error indicators such as knocking, skipping, or unusual vibrations
- Perform a comprehensive cosmetic inspection to confirm the device’s exterior meets aesthetic and quality standards, free from visible damage or wear
Technician Inspection and Recertification Checklist: Shakers
The Following Checklist Is to Be Performed on All Incoming and Outgoing Pieces of Equipment| Task | Completed? | Remarks? |
| Validate stable, correct voltage outputs from power supply and PCB | Completed | |
| Inspect display for dim, flickering, or dead pixels; replace as needed | Completed | |
| Test button functionality for responsiveness and accuracy across all settings | Completed | |
| Inspect bearings and housing for wear; replace as needed to prevent disruption | Completed | |
| Examine drive belt for cracking, fraying, or material breakdown; replace as required | Completed | |
| Measure and adjust motor drive belt tension to optimal specifications | Completed | |
| Verify onboard timer accuracy; replace if it deviates from expected performance | Completed | |
| Calibrate shaker rotation speed using a NIST-traceable tachometer | Completed | |
| Run 8-12 hour continuous test; observe platform for smooth, consistent motion | Completed | |
| Perform comprehensive cosmetic inspection for quality standards compliance | Completed |
New Brunswick Innova 2100 Manual
Click Here to View all the Technical Specs for the Innova 2100


Click Here to View the Technical Specs for the Innova 2100