SHEL LAB SSI2 Incubator Shaker
Temp. Range
Ambient +5°C to 70°C
Speed Range
30 to 300 RPM
Temp. Uniformity
± 0.25°C at 30°C
- Compact benchtop design ideal for space-constrained laboratory environments
- Front-mounted LED display shows temperature, shaking speed, and run time for easy monitoring
- Over-temperature and over-speed protection systems help safeguard samples and equipment
- High accuracy control of shaking and incubation conditions for repeatable results
- Built-in timer allows precise control over experiment duration
- Stable operation designed for long service life and consistent laboratory use
- Suitable for a wide range of biological and research applications
Powered by an integrated microprocessor, the system continuously verifies and maintains set parameters to ensure consistent, repeatable results. The unit supports adjustable shaking speeds with tight accuracy, along with stable temperature control for a variety of applications. Built-in safety features, including over-temperature and over-speed protection, help safeguard samples while supporting long-term instrument reliability. Designed for efficiency and ease of use, the SHEL LAB SSI2 Incubator Shaker provides dependable performance in a compact footprint, making it well suited for routine laboratory workflows requiring both agitation and temperature control.
All of our equipment will be fully tested to perform at factory specifications before being shipped.
The SHEL LAB SSI2 Incubator Shaker includes:
- > NIST Calibration and Preventative Maintenance Report
- > Power Cord
- > Operator's Manual
- > Full 180 Day Parts and Labor Warranty
SHEL LAB SSI2 Incubator Shaker Specifications
| Speed Range | 30 to 300 RPM |
| Speed Accuracy | ± 4 RPM |
| Temperature Range | Ambient +5°C to 70°C |
| Temperature Uniformity | ± 0.25°C at 30°C |
| Temperature Accuracy | ± 0.2°C at 30°C |
| Timer | 99 Hours and 59 Minutes |
| Interior Dimensions (W x D x H) | 9.5 x 11 x 9.5 in. (23.5 x 29.2 x 23.5 cm) |
| Exterior Dimensions (W x D x H) | 11.3 x 15.8 x 11.5 in (28.6 x 40 x 29.4 cm) |
| Electrical Requirements | 110-120V, 50/60Hz, 3A |
- Examine the chamber glass for cracks or chips, replacing it as needed to maintain structural integrity.
- Inspect door seals for signs of wear or damage, replacing them to ensure a tight seal.
- Check the display for brightness and clarity, replacing any dim or dead pixels to maintain optimal visibility.
- Test all buttons to confirm full functionality and consistent responsiveness.
- Replace all platform assembly bearings to ensure smooth and reliable motion.
- Inspect the drive belt for wear, replacing it if torn or cracked to maintain performance.
- Examine all wiring for frays, tears, or breakages, addressing any issues for electrical safety.
- Verify each PCB test point, replacing any malfunctioning components to ensure system reliability.
- Check drive belt tension to confirm correct alignment and function.
- Confirm the compressor’s operation, cleaning condenser filter and fins for efficient cooling.
- Calibrate internal temperature accuracy using an NIST-traceable temperature probe.
- Measure and calibrate platform RPMs with an NIST-traceable tachometer to ensure precision.
- Conduct a final cosmetic inspection to verify all surfaces meet appearance standards.
Technician Inspection and Recertification Checklist
The Following Checklist Is to Be Performed on All Incoming and Outgoing Equipment| Task | Completed? | Remarks? |
| Examine chamber glass for cracks or chips, replace as needed | Completed | |
| Inspect door seals for wear, replace to ensure tight seal | Completed | |
| Check display brightness, replace dim or dead pixels | Completed | |
| Test all buttons for full functionality and responsiveness | Completed | |
| Replace platform assembly bearings for reliable motion | Completed | |
| Inspect drive belt for wear, replace if torn or cracked | Completed | |
| Examine wiring for frays or breakages, repair as needed | Completed | |
| Verify PCB test points, replace faulty components | Completed | |
| Check drive belt tension for proper alignment | Completed | |
| Confirm compressor functionality, clean filter and fins | Completed | |
| Calibrate internal temperature with NIST probe | Completed | |
| Calibrate platform RPM with NIST-traceable tachometer | Completed | |
| Conduct cosmetic inspection for appearance standards | Completed |
Downloads

Click Here to View the Technical Specs for the SHEL LAB SSI2 Incubator Shaker