Thermo Scientific Heratherm IMC 18 Compact Microbiological Incubator
Temperature Range
Ambient +17°C to 40°C
Temperature Uniformity
± 1°C at 37°C
Volume
0.65 cu. ft. (18L)
- Digital display provides continuous monitoring of chamber temperature
- Simple control panel allows intuitive operation and precise adjustments
- Smooth interior surfaces are easy to clean for routine maintenance
- Interior lighting enhances visibility during use
- Compact design at 15.87 lb. and 13.7 x 17.9 x 15.8 in. makes it ideal for small lab spaces
This compact 18L incubator features smooth, easy-to-clean interior surfaces and a clear digital display that continuously shows the current chamber temperature. The straightforward control panel allows adjustments in 1°C increments for precise operation. Additional design elements include a condensation tray for moisture collection, interior lighting for improved visibility, and a lightweight build at only 15.87 lb. Compact and efficient, the IMC 18 delivers reliable temperature control and consistent performance for small-scale laboratory applications.
All of our equipment is fully tested to perform at factory specifications before being shipped.
The Thermo Scientific Heratherm IMC 18 Compact Microbiological Incubator includes:
- > 3 x Shelves
- > NIST Calibration and Preventative Maintenance Report
- > Power Cord
- > Operator's Manual
- > Full 180 Day Parts and Labor Warranty
Thermo Scientific Heratherm IMC 18 Compact Microbiological Incubator Specifications
| Temperature Range | Ambient +17°C to 40°C |
| Temperature Uniformity | ± 1°C at 37°C |
| Temperature Stability | ± 0.2°C at 37°C |
| Volume | 0.65 cu. ft. (18L) |
| Internal Dimensions (W x D x H) | 7.87 x 12.2 x 12.2 in. (19.9 x 31 x 31 cm) |
| External Dimensions (W x D x H) | 10.24 x 18.50 x 16.34 in (26 x 47 x 41.5 cm) |
| Weight | 15.87 lb. (7.2 kg.) |
| Electrical Requirements | 100-240V, 50/60Hz, 0.85A |
- Inspect the display for any dim, flickering, or dead pixels, replacing any affected areas to maintain full readability and operational clarity
- Thoroughly examine external regulators for any signs of damage, wear, or malfunction (if applicable), replacing any compromised parts
- Inspect temperature, COâ‚‚, and Hâ‚‚O sensors (if applicable), ensuring each sensor is functioning correctly and accurately reporting conditions
- Conduct a detailed inspection of all internal wiring for frays, tears, or breakages; replace any compromised wires to ensure safe and reliable connections
- Verify that software settings align with the internal components and calibration specifications, adjusting configurations as needed for accurate operation
- Inspect and clean the fan, ensuring it is free from dust or obstructions; replace if performance is below required standards
- Examine wheels and leveling mounts for structural integrity, ensuring proper balance and stability for safe operation
- Inspect door gaskets and latches for any signs of wear or damage, replacing if necessary to maintain a secure seal and optimal environmental control
- Calibrate temperature accuracy at 37°C using a NIST-traceable probe, confirming it meets required tolerances
- Calibrate COâ‚‚ level to 5% using a Fyrite combustion test kit (if applicable), ensuring precise atmospheric conditions
- Monitor temperature and COâ‚‚ stability over a 24-hour period, verifying consistent operation within specified ranges
- Conduct a thorough cosmetic inspection to confirm all external surfaces and components meet quality standards, free from visible damage or wear
Technician Inspection and Recertification Checklist: Incubator
The Following Checklist Is to Be Performed on All Incoming and Outgoing Pieces of Equipment| Task | Completed? | Remarks? |
| Inspect display for dim, flickering, or dead pixels; replace for readability | Completed | |
| Examine external regulators for damage or malfunction; replace compromised parts | Completed | |
| Inspect temperature, COâ‚‚, and Hâ‚‚O sensors for correct function and accuracy | Completed | |
| Inspect internal wiring for frays, tears, or breakages; replace compromised wires | Completed | |
| Verify software settings align with components and calibration specs; adjust if needed | Completed | |
| Clean fan and remove dust/obstructions; replace if performance is substandard | Completed | |
| Examine wheels and leveling mounts for structural integrity and balance | Completed | |
| Inspect door gaskets and latches for wear or damage; replace to maintain seal | Completed | |
| Calibrate temperature at 37°C with NIST-traceable probe to confirm accuracy | Completed | |
| Calibrate COâ‚‚ level to 5% with Fyrite test kit for atmospheric precision | Completed | |
| Monitor temperature and COâ‚‚ stability over 24-hour period to verify consistency | Completed | |
| Conduct cosmetic inspection to confirm quality of external surfaces and components | Completed |


Click Here to View the Technical Specs for the Thermo Scientific Heratherm IMC 18 Compact Microbiological Incubator