Thermo Scientific SuperSealer, Cat. #: 4110-11
Processing Speed
10 to 15 seconds/plate, block or rack of tubes
Component Compatibility
Microplates, blocks and storage tube racks
Compatible Sealing Options
Thermo Scientific Matrix SepraSeal mats, CapMats, and the SuperSealer Adhesive Seal Mat
- Automatically seals plates, blocks, and tube racks of nearly any height with no manual adjustments
- Provides consistent and reliable sealing for sample storage and liquid handling applications
- Compatible with Thermo Scientific Matrix SepraSeal mats for liquid handling and single-tube access
- Works with Matrix CapMats for complete plate and block sealing during storage
- Simple drawer-loading operation
- Ensures uniform seal integrity across a wide range of plate and block formats
- Reduces manual handling errors and improves lab workflow efficiency

Thermo Scientific Matrix Sealing options are required for operation, and not included with purchase of the Thermo Scientific SuperSealer, Cat. #: 4110-11.
All of our equipment is fully tested to perform at factory specifications before being shipped.
The Thermo Scientific SuperSealer, Cat. #: 4110-11 includes:
- > Power Cord
- > Full 180 Day Parts and Labor Warranty
Thermo Scientific SuperSealer, Cat. #: 4110-11 Specifications
| Processing Speed | 10 to 15 seconds/plate, block or rack of tubes |
| Dimensions (W x D x H) | 6.5 x 12.5 x 13.5 in. (16.5 x 31.75 x 34.3 cm) |
| Weight | 30 lbs. (13.5 kg) |
| Electrical Requirements | 24 VDC, 2.1A |
- Install new waste and buffer bottles to ensure proper fluid containment and system functionality.
- Integrate a new pump into the system, verifying compatibility and secure connections.
- Verify that the power supply and PCB output the correct voltages for reliable component operation.
- Conduct a self-test on the microplate washer, evaluating all operational parameters.
- Inspect the X-axis motor belt for signs of wear, such as tears, frays, or breakages, replacing if necessary.
- Examine dispense and aspirate tubes for any damage that could affect fluid flow accuracy.
- Confirm internal pump functionality, replacing seals as needed to maintain optimal performance.
- Inspect all internal wiring for frays, tears, or breakages, addressing any faults for electrical safety.
- Verify functionality of all internal and external sensors, ensuring accurate readings across the unit.
- Disinfect the unit using an appropriate disinfection cycle to ensure sterility and safety.
- Check that residual aspiration levels are within the manufacturer’s specified limits for accuracy.
- Conduct a final cosmetic inspection to verify that all external surfaces meet appearance standards.
Technician Inspection and Recertification Checklist: Microplate Washer
The Following Checklist Is to Be Performed on All Incoming and Outgoing Equipment| Task | Completed? | Remarks? |
| Install new waste and buffer bottles | Completed | |
| Integrate new pump into system, verifying secure connections | Completed | |
| Verify power supply and PCB output correct voltages | Completed | |
| Conduct microplate washer self-test and evaluate results | Completed | |
| Inspect X-axis motor belt for wear, replacing if necessary | Completed | |
| Examine dispense and aspirate tubes for any damage | Completed | |
| Confirm internal pump functionality, replace seals as needed | Completed | |
| Inspect internal wiring for frays, tears, or breakages | Completed | |
| Verify functionality of all internal and external sensors | Completed | |
| Disinfect unit with appropriate disinfection cycle | Completed | |
| Check residual aspiration levels meet specifications | Completed | |
| Conduct cosmetic inspection for appearance standards | Completed |


Click Here to View the Technical Specs for the Thermo Scientific SuperSealer, Cat. #: 4110-11