Thermo Sorvall Legend RT Plus Refrigerated Benchtop Centrifuge
Maximum Speed
4,150 RPM
Temperature Range
-9 to +40C
Max. Capacity
4 x 750 ml
- Easy-to-read display and control panel for effortless operation of centrifuge functions
- Reaches a maximum force of 24,400 x g, suitable for intensive separation
- Constructed with 8 mm steel for durability and safety
- Lid with viewing window allows for sample observation without interruption
- Secure lid lock with safety check ensures the centrifuge operates when the lid is locked
- Automatic rotor identification streamlines workflow
- Switches between speed and RCF display effortlessly, even during operation
All of our equipment is fully tested to perform at factory specifications before being shipped.
Please confirm this rotor meets your application needs and request a different rotor, if necessary. Available rotors can be found in our Rotor Compatibility Guide.
The Thermo Sorvall Legend RT Plus Refrigerated Benchtop Centrifuge includes:
- > 75006434 Swing Bucket Rotor and Buckets
- > 1 Set of 15ml Adapters
- > 1 Set of 50ml Adapters
- > NIST Centrifuge Calibration and Preventative Maintenance Report
- > Power Cord
- > Operator's Guide
- > Full 180 Day Parts and Labor Warranty
Thermo Sorvall Legend RT Plus Refrigerated Benchtop Centrifuge Specifications
| Maximum Speed | 15,000 RPM |
| Minimum Speed | 300 RPM |
| Maximum RCF | 24,400 x g |
| Maximum Capacity | 4 x 750ml |
| Temperature Range | -9°C to 40°C |
| Timer | Up to 9 hours 59 minutes, 59 seconds, with continuous run (hold) |
| Display | Full color touch screen interface |
| Program Storage | 4 user programs |
| Noise Level | < 55 dB(A) |
| Dimensions (H x W x D) | 14.3 x 28.7 x 26.2 in. (36.2 x 73.3 x 66.6 cm) |
| Weight | 288 lb. (131 kg) |
| Electrical Requirements | 115V, 60Hz, 12A |
- Confirm the power supply output voltages match specified requirements for stable distribution to all internal components
- Measure and verify voltages at PCB test points to ensure accurate power delivery and circuit integrity
- Confirm rotor compatibility with the centrifuge model and check that rotor detection systems recognize the rotor type
- Inspect the exterior for any cosmetic or structural damage that could affect performance or safety
- Check the door mechanism alignment to ensure secure and smooth opening and closing
- Inspect and replace the gas strut with an OEM part to maintain proper door support and safety
- Examine the rotor chamber bowl for dents or damage and replace as needed to ensure safe operation
- Replace and confirm full functionality of all lid lock switches to maintain secure closure
- Inspect and lubricate the door lock mechanism, applying grease to the lid lock rail for smooth operation
- Test compressor functionality (if applicable) to ensure proper operation and consistent temperature control
- Conduct an 8-12 hour cycle test to validate consistent performance over prolonged use
- Confirm rotor motor stability, check for unusual noise, and assess mechanical integrity during operation
- Inspect the condensation drain and clear any clogs to prevent moisture buildup in the rotor chamber
- Verify RPM accuracy using an NIST-traceable tachometer and perform calibration as necessary
- Check the centrifuge error log to ensure zero recorded issues, confirming system reliability
Technician Inspection and Recertification Checklist: Centrifuges
The Following Checklist Is to Be Performed on All Incoming and Outgoing Pieces of Equipment| Task | Completed? | Remarks? |
| Confirm power supply output voltages match specified requirements | Completed | |
| Measure and verify voltages at PCB test points for accuracy | Completed | |
| Confirm rotor compatibility and detection for proper identification | Completed | |
| Inspect exterior for cosmetic or structural damage | Completed | |
| Check door mechanism alignment for secure opening and closing | Completed | |
| Inspect and replace gas strut with OEM part as needed | Completed | |
| Examine rotor chamber for dents or damage and replace if necessary | Completed | |
| Replace and confirm functionality of all lid lock switches | Completed | |
| Lubricate door lock mechanism and lid lock rail for smooth operation | Completed | |
| Test compressor (if applicable) for proper operation and cooling | Completed | |
| Run 8-12 hour cycle test to ensure consistent performance | Completed | |
| Check rotor motor for stability, noise, and integrity | Completed | |
| Inspect and clear condensation drain to prevent buildup | Completed | |
| Verify RPM accuracy with NIST traceable tachometer and calibrate | Completed | |
| Check centrifuge error log for zero recorded issues | Completed |
Preventative Maintenance Performed on The Thermo Sorvall Legend RT Plus Refrigerated Benchtop Centrifuge
- Door Latch Assembly Checked for Full Function
- Door Hinges are Checked and Lubed as Needed
- Drive Belt is Checked for Rips and Tears and Replaced if Needed
- Rotors and O-rings are Lubed as Needed
- Lamps and Display are Checked and Replaced if Dim
- Line Cord is Checked for Signs of Fray or Damage and Replaced Accordingly
- Internal Circuitry is Checked for Faulty/Shorted Components and Replaced Accordingly