Tuttnauer 2540M Sterilizer
The The Tuttnauer 2540M Autoclave is designed to compliment any healthcare facility. The bright new easy-to-use panel was designed with the operator in mind. The 2540M autoclave will satisfy all sterilization needs without compromising on quality, safety or reliability. Automatic shut off at the end of both the sterilization and dry cycles. A long life electro polished chamber and door. Double safety locking device prevents door from opening while chamber is pressurized. Drain valve is located on the front, allowing for quick and easy draining of water reservoir. Dual safety thermostat to protect against overheating. Standard unwrapped cycle Hot start: 14 min, Cold Start 30 min. Cycle times are approximate and may vary depending on instrument loads.
This Autoclave is unused and fully tested.
The Tuttnauer 2540M Analog Autoclave includes:
- > 4 x Trays
- > Power Cord
- > Operator's Guide
- > Full 180 Day Parts and Labor Warranty
Tuttnauer 2540M Sterilizer Specifications
|
Chamber Dimensions (diameter x L) |
10 x 18.7 in (254 x 475 mm) |
|
Chamber Volume |
6 gal (23 L) |
|
Water Reservoir Volume |
0.66 gal (3 L) |
|
Tray Dimensions (D x W x H) |
16.3 x 6.7 x 0.8 in (415 x 170 x 20 mm) |
|
Electrical Requirements |
120V, 11.7A, 1400W |
- Verify power supply output to ensure precise voltage delivery as per equipment specifications
- Check full display functionality, replacing any dead or dim pixels for optimal clarity
- Confirm unit is level to maintain stability and accurate operational performance
- Inspect door seal integrity, replacing if any wear or damage compromises airtight performance
- Examine and clean both external and internal filters to ensure unobstructed airflow and system efficiency
- Execute comprehensive cycle testing to validate consistent operation
- Verify printer functionality (if applicable) to ensure precise print outputs without error
- Assess internal plumbing system for any leaks or pressure inconsistencies
- Inspect all electrical connections and wiring for secure attachment and optimal conductivity
- Verify functionality of internal switches to ensure reliable engagement and operational control
- Inspect and clean the water reservoir to maintain purity and prevent contamination
- Confirm accuracy of pressure readings, recalibrating if deviations are identified
- Perform final test cycles, ensuring zero errors for validated operational readiness
Technician Inspection and Recertification Checklist: Autoclaves
The Following Checklist Is to Be Performed on All Incoming and Outgoing Equipment| Task | Completed? | Remarks? |
| Verify power supply output voltages | Completed | |
| Check display functionality and replace dead/dim pixels | Completed | |
| Confirm unit leveling for stability | Completed | |
| Inspect and replace damaged door seal | Completed | |
| Clean external and internal filters for airflow efficiency | Completed | |
| Conduct comprehensive cycle testing | Completed | |
| Confirm printer functionality (if applicable) | Completed | |
| Assess plumbing for leaks or pressure issues | Completed | |
| Inspect electrical connections for secure and optimal conductivity | Completed | |
| Verify internal switch functionality | Completed | |
| Inspect and clean water reservoir | Completed | |
| Confirm pressure reading accuracy and recalibrate if needed | Completed | |
| Perform final test cycles with zero errors | Completed |