Output Current Range
10 mA~3 A
Output Power
300 W
Output Voltage Range
5 to 250V
- Compact, stackable design compatible with most electrophoresis systems
- Built-in safety features including short circuit, overcurrent, and overvoltage protection
- No-load and load-change detection systems ensure safe operation
- Automatic recovery function resumes operation after power failure
- Versatile functionality suitable for DNA, RNA, protein separations, blotting, and isoelectric focusing
- Programmable timer range from 1 minute to 99 hours 59 minutes
The VWR 250V is a stackable, compact power supply compatible with most electrophoresis systems. For safety, the 250V includes no-load and load-change detection systems, short circuit and over current/over voltage protection, and automatic recovery after a power failure.
The VWR 250V can meet a wide range of applications, including DNA, RNA and protein separations; isoelectric focusing; and blotting.
All of our equipment is fully tested to perform at factory specifications before being shipped.
The VWR 250V Electrophoresis Power Supply includes:
- > Power Cord
- > Operator's Guide
- > Full 180 Day Parts and Labor Warranty
VWR 250V Electrophoresis Power Supply Specifications
|
Output Current Range |
10 3000 mA |
|
Output Power Range |
1 300 W |
|
Output Voltage Range |
5 250 V |
|
Timer |
1 min to 99 hr 59 min |
|
Dimensions (W x D x H) |
19 x 25 x 8 cm |
|
Input Voltage |
115 V |
- Verify internal power supply output for correct voltage in alignment with equipment specifications
- Inspect LED display for any dim or dead pixels, ensuring optimal readability
- Examine internal wiring and connections, checking for any rips, tears, or compromised insulation
- Ensure fan is clean and fully operational to maintain adequate cooling
- Test PCB test points for proper voltage output, confirming consistent circuit performance
- Validate functionality of all buttons and switches, ensuring responsive control
- Measure and confirm constant voltage, amplitude, and wattage using precise resistance values
- Cross-check displayed voltage with multimeter readings for accuracy
- Monitor for rapid resistance changes, software errors, and power fluctuations
- Inspect line cord for any signs of wear, cuts, or damage impacting safety
- Confirm cosmetic condition meets quality standards, free of any damage affecting functionality or aesthetics
Technician Inspection and Recertification Checklist: Electrophoresis Power Supplies
The Following Checklist Is to Be Performed on All Incoming and Outgoing Equipment| Task | Completed? | Remarks? |
| Verify internal power supply output voltage | Completed | |
| Inspect LED display for dim or dead pixels | Completed | |
| Examine internal wiring for rips or tears | Completed | |
| Ensure fan is clean and fully operational | Completed | |
| Test PCB test points for voltage accuracy | Completed | |
| Validate functionality of buttons and switches | Completed | |
| Confirm constant voltage, amplitude, and wattage with resistance | Completed | |
| Cross-check displayed voltage with multimeter | Completed | |
| Monitor for rapid resistance changes and power fluctuations | Completed | |
| Inspect line cord for wear or damage | Completed | |
| Confirm cosmetic condition meets quality standards | Completed |